Safety warnings

For  the  installer

• When used as an extractor unit, the hood must

be fitted with a  150mm diameter hose.

• Should there already be a pipe with a diameter

of 125mm that ducts to the outside through the

wall or roof, it is possible to use the 150/125 mm

reduction flange provided.  In this case the hood

will be slightly noisier.

•

When  installing  the  hood,  make  sure  you

respect  the  following  minimum  distance

from the top edge of the cooking hob/ring

surfaces:

electric  cookers

500  mm

gas  cookers

700  mm

The hood can be installed above these heights

but for optimum performance it should be

installed at the distance quoted for the

appropriate heat source.

• The national Standard on fuel-burning systems

specifies a maximum depression of 0.04 mbar in

such rooms.

• The air outlet must not be connected to chimney

flues or combustion gas ducts. The air outlet

must under no circumstances be connected to

ventilation ducts for rooms in which fuel-burning

appliances are installed.

• The air outlet installation must comply with the

regulations laid down by the relevant authorities.

• When the unit is used in its extractor version, a

sufficiently large ventilation hole must be

provided, with dimensions that are approxi-

mately the same as the outlet hole.

• National and regional building regulations

impose a number of restrictions on using hoods

and fuel-burning appliances connected to a

chimney, such as coal or oil room-heaters and

gas fires, in the same room.

• Hoods can only be used safely with appliances

connected to a chimney if the room and/or flat

(air/environment combination) is ventilated from

outside using a suitable ventilation hole approxi-

mately 500-600 cm

 large to avoid the

possibility of a depression being created during

operation of the hood.

• If you have any doubts, contact the relevant

controlling authority or building inspector’s

office.

• Since the rule for rooms with fuel burning

appliances is “outlet hole of the same size as the

ventilation hole”, a hole of 500-600 cm

2

, which

is to say a larger hole, could reduce the perfor-

mance of the extractor hood.

• If the hood is used in its filtering function, it will

operate simply and safely in the above

conditions without the need for any of the

aforementioned measures.

• When the hood is used in its extractor function,

the following rules must be followed to obtain

optimal operation:

— short and straight outlet hose

— keep bends in outlet hose to a minimum

— never install the hoses with an acute angle,

they must always follow a gentle curve.

— keep the hose as large as possible

(preferably the same diameter as the

outlet hole).

• Failure to observe these basic instructions will

drastically reduce the performance and increase

the noise levels of the extractor hood.

Содержание EFC 9440

Страница 1: ...Gebrauchsanweisung Noticed utilisationetd installation Installatie engebruiksaanwijzing EFC 9440 F NL D Usermanual Instruccionesdemontajeymanejo ManualdeInstruções UK P E ...

Страница 2: ...nstruction manual and keep it available at use of the cooker hood Safety warnings 32 For the installer 32 For the user 33 Description of the Appliance 34 Extraction 34 Recirculation 34 Control Panel 34 Maintenance and care 35 Cleaning the hood 35 Metal grease filter 35 Removing the metal grease filter 35 Charcoal filter 36 Changing the light bulb 36 What to do if 37 Special accessories 37 Technica...

Страница 3: ...al and regional building regulations impose a number of restrictions on using hoods and fuel burning appliances connected to a chimney such as coal or oil room heaters and gas fires in the same room Hoods can only be used safely with appliances connected to a chimney if the room and or flat air environment combination is ventilated from outside using a suitable ventilation hole approxi mately 500 ...

Страница 4: ... The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance WARNING Ensure that the appliance is switched off before replacing the lamp to avoid the possibility of electric shock This appliance is marked according to the European directive 2002 96 EC on Waste Electrical and Ele...

Страница 5: ... on after cooking for about 15 minutes or until all the odours have disappeared The control switches are located on the unit s front panel Light switch this switch is used to turn the light fitted in the hood on and off Extractor fan switch used to turn the fan off Push button 1 used to set the fan to speed 1 Push button 2 used to set the fan to speed 2 Push button 3 used to set the fan to speed 3...

Страница 6: ...grease filters is to absorb grease particles which form during cooking and it must always be used either in the external extraction or internal recycling function Attention the metal grease filters must be removed and washed either by hand or in the dishwasher every four weeks Removing the metal grease filter First push the metal grease filter stop f1 backwards then extract the filter f2 pulling d...

Страница 7: ...ith a temperature of maximum 100º C After approximately three years of use the carbon filter should be replaced with a new as the odour reduction capacity will be reduced Fitting Remove the frame i which supports the filter h by turning 90 the two knobs g Insert the charcoal filter inside the frame and put all parts back in their place Fig 4 To remove proceed in the reverse order Always specify th...

Страница 8: ...utlets are not blocked The cooker hood has The safety cut out device has been tripped switched off during operation Turn off the hob and then wait for the device to reset If the hood has been installed below the heights indicated in the installation instructions the motor will cut out frequently which will damage the hood If after all these checks the problem persists contact your local Service Fo...

Страница 9: ...tically routed to the Service Centre covering your post code area For the address of your local Service Force Centre and further information about Service Force please visit the website at www serviceforce co uk Please ensure that you have read the section What to do if as the engineer will make a charge if the fault is not a mechanical or electrical breakdown even the appliance is under warranty ...

Страница 10: ...sary to provide a fixed connection the hood must only be installed by an electrician authorised by the local electricity board When installing an omnipolar disconnector with a distance of at least 3 mm between contacts must be provided Fixed connection of the appliance must only be carried out by an authorised electrician Electrical connection for UK only Safety warnings for the electrician Connec...

Страница 11: ... to the support 1 reduction flange Ø 125 120 mm Only for model EFC 9460 X 942 120 705 1 support bracket 5 wood screws 5 x 45 mm for wall mounting 5 wall plugs Ø 8 mm for wall mounting 2 metal screws 2 9 x 6 5 for chimney flue mounting 6 metal screws 4 x 20 to affix the screen to the cooker hood 1 allen spanner for TORX 10 20 screws ...

Страница 12: ...hood 7 adjust its position 8 9 and from the inside of the hood mark one point for final fixing 10 remove the hood 11 and drill an hole Ø 8mm 12 fit a wall plugs 13 Drill two holes Ø 8mm on the upper side close to the ceilling 14 fit two wall plugs and fix the chimney support with two screws 15 Hang the hood again 16 Fix it securely with a screw 17 To simplify the installation operation remove the ...

Страница 13: ...er of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world Electrolux 2003 ...