Installation

Wall unit mounting - Fig. 9

Disconnect the hood during electrical connection, by turning the home mains switch off.

•

Rest the suction unit on a flat surface and thread the lower part of the hood onto it

 (1)

.

•

Make all the electrical connections between the two parts

 (2)

.

•

Fasten the hood to the suction unit using 10 screws 

(3), 

before fixing check that the metal band (steam shield)

that holds the lamp and the filter/s / greases is well attached to the front.  If necessary adjust the position

of the band forwards until the end stop.  .

• Sign the wall with a center line, this will aid mounting procedure 

(4)

, position the template so that the mid line

printed on the template matches with the center line previously signed, the lower side of the template

corresponds to the lower side of the hood once mounted 

(5)

.

• Drill two holes Ø 8mm and fix the support bracket with two wall plugs and screws 

(6)

.

• Hang the hood 

(7)

 adjust its position 

(8-9)

and from the inside of the hood sign one

point for definitive fixing 

(10)

,

remove the hood 

(11)

 and drill

an hole Ø 8mm 

(12)

, fit a

wall plugs 

(13)

.

• Drill two holes Ø 8mm on

the upper side close to

the ceilling 

(14)

, fit two

wall plugs and fix the

chimney support with two

screws 

(15)

.

• Hang the hood again

 (16)

.

• Fix it definitively with a

screw 

(17)

. To simplify

the mounting operation

remove the carbon filter frame.

• In case the hood is to be used in

filter version

, mount the

deflector 

F

 on the chimney

support 

G

 with four screws

2,9x6,5 and fit an exhausting

pipe 

(18)

 to connect deflector to

the outlet hole 

D

 of the hood.

In case the hood is to be used in

exhausting version, then the

deflector must not be mounted

and fit an exhausting pipe

(18)

 to connect outlet

hole 

D

 of the hood to the

outside.

• Make electrical

connection 

(13)

, but

leave the hood

disconnected from the

home general electric

panel.

• Fix the chimney 

(16a)

 to the

chimney support 

(16b)

.

Slide down the lower section on the proper housing on

top of the hood. Connect the hood the the home general electric panel and check if the hood work properly.

Fig. 9

Содержание EFC 6420

Страница 1: ...Gebrauchsanweisung Notice d utilisation et d installation EFC 6420 EFC 9420 F D Istruzioni di montaggio ed uso User manual UK I ...

Страница 2: ...t available at use of the cooker hood Safety warnings 31 For the installer 31 For the user 31 Description of the Appliance 32 Extractor version 32 Filter Version 32 Control Panel 33 Maintenance and care 34 Cleaning the hood 34 Metal grease filter 34 Removing the metal grease filter 34 Charcoal filter 35 Changing the light bulb 35 What to do if 36 Special accessories 36 Technical assistance service...

Страница 3: ...the perfor mance of the extractor hood If the hood is used in its filtering function it will operate simply and safely in the above conditions without the need for any of the aforementioned measures When the hood is used in its extractor function the following rules must be followed to obtain optimal operation short and straight outlet hose keep bends in outlet hose to a minimum never install the ...

Страница 4: ...ide via a hose connected to the coupling ring Fig 1 In order to obtain the best performance the hose should have a diameter equal to the outlet hole Fig 1 Filter Version The air is filtered through a charcoal filter and returned to the kitchen You will need an original ELECTROLUX charcoal filter for the filtering function See Special Accessories Fix the deflector using 4 screws Ø 3 5x9 5 mm Fig 2 ...

Страница 5: ...hours Correct ventilation If the cooker hood is to work correctly there must be an under pressure in the kitchen It is important to keep the kitchen windows closed and have a window in an adjacent room open A Main switch hood off B Start and choice of motor speed 1 2 3 1 2 C Indicates speed 1 LED D Indicates speed 2 and saturation of the grease filter LED E Indicates speed 3 and saturation of the ...

Страница 6: ...grease filter The purpose of the grease filters is to absorb grease particles which form during cooking and it must always be used either in the external extraction or internal recycling function Attention the metal grease filters must be removed and washed either by hand or in the dishwasher every four weeks Removing the metal grease filter Pull the handles downards then extract the filter Fig 4 ...

Страница 7: ...maximum 100º C After approximately three years of use the carbon filter should be replaced with a new as the odour reduction capacity will be reduced Fitting Remove the frame i which supports the filter h by turning 90 the two knobs g Insert the charcoal filter inside the frame and put all parts back in their place Fig 5 To remove proceed in the reverse order Always specify the hood model code num...

Страница 8: ...as The safety cut out device has been tripped switched off during operation Turn off the hob and then wait for the device to reset If the hood has been installed below the heights indicated in the installation instructions the motor will cut out frequently which will damage the hood If after all these checks the problem persists contact your local Service Force Centre quoting the model and serial ...

Страница 9: ...ological growth Technical assistance service You are welcome to telephone our technical assistance service see list of technical assistance centres whenever you need information or in the unlikely event of a fault For service in Australia call 1300 650 020 When calling please be ready to specify 1 The model code number 2 The serial number E Nr 3 The manufacturing number F Nr This information is sh...

Страница 10: ...sary to provide a fixed connection the hood must only be installed by an electrician authorised by the local electricity board When installing an omnipolar disconnector with a distance of at least 3 mm between contacts must be provided Fixed connection of the appliance must only be carried out by an authorised electrician Electrical connection for UK only Safety warnings for the electrician Connec...

Страница 11: ... metal screws 2 9 x 6 5 for chimney flue mounting 12 metal screws 4 x 20 to affix the screen to the cooker hood 1 allen spanner for TORX screws Attention The deflector and the relative fixing screws are not supplied when the upper section of the chimney has no side slots Assembling the chimney flue support bracket 3 parts The three parts should be fixed with 4 screws the support extension is adjus...

Страница 12: ...t with two wall plugs and screws 6 Hang the hood 7 adjust its position 8 9 and from the inside of the hood sign one point for definitive fixing 10 remove the hood 11 and drill an hole Ø 8mm 12 fit a wall plugs 13 Drill two holes Ø 8mm on the upper side close to the ceilling 14 fit two wall plugs and fix the chimney support with two screws 15 Hang the hood again 16 Fix it definitively with a screw ...

Страница 13: ... that proof of purchase is required for in guarantee service calls Help us to help you Please determine your type of enquiry before writing or telephoning When you contact us we need to know Your name Address and post code Telephone number Clear and concise details of the fault Name and model of the appliance E number This information can be found on the rating plate which can be seen when the gre...

Страница 14: ...astic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the European Community EC or European Free Trade Area Appliances found to be in use within a commercial environment plus those which are subject to rental agreements Products of Electrolux manufacture which are not marketed by Electrolux European Guarantee If you should move to ano...

Страница 15: ...LI11TC Ed 07 04 ...

Отзывы: