55
18
18
18
18
18
18
18
18
18
18
M
17
X
X
20
20
X
19
19
Fig. 11
Carry out electrical connection of control panel and bulbs (17).
Join the two bottom sections of the flue covering the support (18) using 6 screws and springs (3 each
side, see the plan diagram for joining the two sections - springs must be fixed horizontally).
Insert the bottom section of the flue in its seat so that it completely covers the motor compartment and
electrical connection box, then ensure it from inside the hood using two screws (19).
Apply the 2 tabs (20 - supplied) to cover the fixing points of the bottom flue (CAUTION! THE BOTTOM
FLUE TABS ARE THE NARROWER AND SHALLOWER ONES).
The wider and deeper tabs are those used for the top flue, and must be cut to size.
If necessary, slightly expand the tabs to ensure their adherence to the flue.
Turn the mains power on again at the central electrical panel and check for correct hood operation.