background image

Содержание EFC 009 X

Страница 1: ...Gebrauchsanweisung Manuel d utilisation EFC 009 X D F I UK Istruzioni per l uso User Manual ...

Страница 2: ...sting version 38 Recirculating version 38 For both version 39 Mounting of carbon filter for recirculating version 40 Using the hood 41 Intensive speed button 41 Control devices for the grease filter and carbon filter 41 Grease filter saturation led 41 Carbon filter saturation led 42 Maintenance 42 Grease filter 42 Carbon filter 42 Cleaning 42 Correct ventilation 42 Changing the lighting elements 4...

Страница 3: ... be connected to flues of other appliances that run on energy sources other than electricity Please keep to the provisions of official direc tives regarding the question of fumes discharge l When the hood is used at the same time of other appliances that run on energy sources other than electricity provision must be made for an adequate supply of air l When installed the hood must be not less than...

Страница 4: ...1 Function The hood may be used as follows Exhausting version Recycling version Exhausting version The air is vented outdoors by a 150 mm duct which must be connected to connecting ring with no return valve A on top of the motor package Fig 2 The hood cannot be connected to flues of other appliances that run on energy sources other than electricity Please keep to the provisions of official direc t...

Страница 5: ...The hood is to be mounted hanging from the roof When installed the hood must be not less than 65 cm above electric burners or 75 cm above gas or mixed fuel burners Fig 4 Electrical connection The hood has a power cord with moulded plug with earth connection to be connected to a wall outlet of 230 V The power outlet should be pre mounted in such a way that the power cord is invisible when the hood ...

Страница 6: ...the ceiling sufficiently long to reach the connec tion ring above the hood once the hood will be fit on place Recirculating version l Fit the deflector from one side of the slots of the upper section of the telescopic supporting structure Fig 6 Attention Slots used must be those perpendicular to the top fixing points for chimney unit l Fix the deflector with bracket supplied and 4 screws 2 9x6 5 F...

Страница 7: ...5 Fig 8 l Fit four auto locking nuts on the four pins located on the upper side of the hood Fig 9 l Fit the glass part on top of the hood l Fit temporarily the hood on the supporting structure by means of the already mentioned pins with nuts to be inserted on the proper holes located on the lower side of the supporting structure Rotate the hood until it stops a Fig 10 l Completely thighten the nut...

Страница 8: ...40 Mounting of carbon filter for recirculating version l Remove the grease filters l Fix the carbon filter with its two screws Fig 12 l Replace the grease filters Fig 12 ...

Страница 9: ...C D G A H I Using the hood Intensive speed button This speed should be used when the concentration of cooking fumes or odours is particularly strong for example when frying cooking fish etc The fast speed will run for about 5 minutes and then return to the speed previously set automati cally 1 2 or 3 or switch off if no speed was selected To turn off the fast speed before the end of the 5 minutes ...

Страница 10: ...en unscrew the two screws that holds the grease filter and pull the filter down Fig 12 Cleaning To clean the outside of the hood use a cloth mois tened with denatured alcohol or neutral liquid detergents Never use products containing abrasives Carbon filter saturation led The LED marked C indicates carbon filter needs to be replaced This must be done after approximately 160 hours of use Read the i...

Страница 11: ...an approved service company Remember to save the purchase recite and the Warranty card only used in some countries Service and spare parts Service and spare parts you will get via your dealer or service company When you order service or spare parts you should be ready to give the product number and model denomination This information you will find on the rating label Take away the grease filter an...

Страница 12: ... 609 m3 h x 225 m3 h full speed 483 m3 h low speed 246 m3 h Dimension Height 752 930 mm Width 1000 mm Depth 700 mm Light energy saving lamp 2 x PL 9 W Grease filter 2 pcs Mains Voltage 230 V Power rating total 205 W x Valid when the hood is used with carbon filter recirculation Dimensions ...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...LI1O4A Ed 12 00 ...

Отзывы: