3.7 Pressure Switch
The pressure switch controls the water level.
Without water, contact 11 - 12 is closed.
fN
Switch point with level
65 mm Ws
Reset point with level
45 mm Ws
The pressure switch is not adjustable.
3.8 Interference Filter
The interference filter is connected in the terminal board paral-
lel to the mains feed.
3.6 NTC-Temperature sensor with
integrated turbidity sensor
NTC
Turbidity sensor
The turbidity sensor function is only activated in cycles AUTO
Function:
The input voltage with the turbidity sensor may be between 6 V
and 11.4 V. (The measurements are described in detail in the
chapter Measuring Points at the Electronic Control (in the base)).
For a clear water the output voltage must always be 4.3 V. If that
value differs due to soiling of the turbidity sensor after a longer
operational period, the Easytronic plus recontrols the input voltage
with the turbidity sensor automatically until the output voltage is
4.3 V. This happens during the final rinse cycle.
If the 4.3 V is not achieved within 8 seconds, the fault C5 is
stored in the fault memory. If the output voltage falls below 3 V in
the prewash cycle and below 3.8 V in the intermediate rinsing
cycle, turbid water will be detected. With the service test routine
the turbidity sensor will be calibrated to 3.5 V not with water but
with air.
That corresponds to 4.3 V with water.
4,3V
output voltage intermediate
4,3V
3V
output voltage prewash
turbit water
clear water
3,8V
Temp.
Widerstand
10°C
9653 Ohm
25°C
4843 Ohm
60°C
1204 Ohm
90°C
445 Ohm
NTC
turbit water
clear water