- 14 -
09.2002 R.K.
599 515 015 EN
5.1 All-Around Water Protection
Aqua-Control Inlet Hose
The inlet hose has a double-wall construction. The inner hose is equipped with a flow restrictor built
into the tap connection, and has a flow rate of 4 litres per minute. The inlet valve (1) is located in the
base of the dishwasher. The safety outer hose (12) is connected to the regeneration chamber. If the
inner hose should burst, the water passes into the tub. The safety pressure switch activates the drain
pump and decreases the waterlevel down to normal level. An additional overflow protection is a
defined overflow through the regeneration chamber. The water flows into the bottom tray and
activates the float switch, which energises the drain pump. This drains the dishwasher preventing
water damage.
Safety level
If the safety level is reached by over-fillling, the safety pressure switch starts the drain pump. The water
is only drained until it has reached the normal level because the reset point of the safety pressure
switch is above the switchpoint of the normal pressure switch.
Leakage Protection
The anti-flood switch in the base tray will activate the drain pump and drain the water from the tub in
the event of an internal leakage. If the float switch is activated, all electric components are switched
off except the electronic and the drain pump.
1
Inlet valve
2
Air break
3
Regeneration water dosage
4
Overflow safety level
5
Safety overflow
6
Inlet to sump from regeneration dosage chamber
7
Regeneration dosage chamber
8
Softener
9
Salt container
10
Non-return valve salt container
11
Regeneration valve
12
Safety inlet hose
13
Base tray
14
Float switch
15
Pressure switch
16
Filter
17
Circulation pump
18
Flow heater
19
Drain pump
20
Non-return valve
21
Spray arms
22
Roof-mounted shower
23
Tub vent
24
Sump assembly