11
30” FULL GAS RANGE INSTALLATION INSTRUCTIONS
Burners and nozzles technical tables
Cooktop burners:
1
- Circular Dual Flame burners.
2
- Circular Single
Flame burners.
3
- Fish burner.
Oven cavity burners:
4
: Broiler burner
5
: Oven burner
Location of the appliance’s Gas and
Electric connections
4
Gas connection
5
Electrical connection
Burner power and bypass table
Burner
No.
1
2
3
Max.
Power
(BTU)
18000
12000
5500 +
5500
Min.
Power
(BTU)
750
3500
2400 +
2400
Bypass
(mm)
75 + 26
58
45 + 45
Natural gas nozzles table (Pressure in W.C.P.: 5”)
Burner
No.
1
2
3
Ext.
nozzle
number
180
155
108 + 108
Int. noz-
zle
number
75
LPG nozzles table (Pressure in W.C.P.: 10”)
Burner
No.
1
2
3
Ext.
nozzle
number
115
102
67 + 67
Int. noz-
zle
number
48
Broiler and oven burners power table
Burner
No.
4
5
Power
(BTU)
17000
11500
Natural gas nozzles table (Pressure in W.C.P.: 5”)
Burner
No.
4
5
Nozzle
number
180
150
LPG nozzles table (Pressure in W.C.P.: 10”)
Burner
No.
4
5
Nozzle
number
117
98
Содержание ECFG3068AS