28
5.16 Dispenser
The new dispenser includes the following features:
• Low voltage driving - 5VDC => Safety
improvement
• Multiple dosage => Performance/Quality
improvement
• Sliding lid => Performance/Quality improvement
5.17 Multi Dosage - Specification
• PERFORMANCE
The dosage of the rinse-aid has to be independent of
the filling status of the container, as long as the refill
indication is not reached. After indicating the refill
minimum for another 2 dosage cycles, the nominal
volume has to be guaranteed.
Dosage Procedure – Multiple Dosage
The first activation impulse opens the detergent lid; no
rinse aid should be dosed into the tub.
With each further activation impulse a dosage volume
of 1.5 ml has to be dosed into the tub.
During Main Wash Phase – Detergent Lid Opening:
STEP
ACTION
TIME
PURPOSE
1
Activation of
coil
0.3 S
Opening the
detergent lid to
release detergent
During Hot Rinse Phase - Rinse Aid Delivery:
STEP
ACTION
TIME
PURPOSE
1
Dosage check
–
Check if rinse aid is
should be delivered
If 0 -> no delivery
the rinse aid
delivery process
should be stopped.
2
Activation of
coil
5 S
Delivery of dose
of rinse aid - 1,5 ml
nominal
3
Pause
10 S
Refill of dosage
chamber
4
Repeat from
Step 2
–
Number of dosages
according to set
level
Содержание E24ID74QPS
Страница 1: ...Publication 5995668042 December 2015 Technical Service Manual DISHWASHERS ...
Страница 2: ......
Страница 18: ...18 5 1 Product Overview 5 Technical Details 5 2 Base Details Rear Side ...
Страница 21: ...21 5 7 Hydraulic Circuit 5 8 Hydraulic Circuit Overview ...
Страница 22: ...22 5 9 Sump Circulation Motor Variants Pump and Heater ...
Страница 24: ...24 5 11 Omega Heater and Pump 5 12 Sump and Drain System Motor Variants ...
Страница 29: ...29 5 18 Control Board for PB100 PB200 5 19 Control Board Replacement ...
Страница 30: ...30 5 20 Example Wiring Diagram for PB100 5 21 Example Wiring Diagram for PB200 ...