electrolux e:line ovens
technical specifications 33
Technical specifications
model
product dimensions
(h x w x d) mm
electrical connection
min. fuse
rating
max. power
rating
max. current
rating
EOEM61AS
595 x 595 x 567
230-240v/50Hz
16A
3.1kW
12.9A
EOEE62AS
595 x 595 x 567
230-240v/50Hz
16A
3.1kW
12.9A
EOEE63AS
595 x 595 x 567
230-240v/50Hz
16A
3.1kW
12.9A
EUEE63AS
888 x 595 x 567
230-240v/50Hz
25A
5.3kW
22.1A
EDEE63AS
1081 x 595 x 567
230-240v/50Hz
25A
5.8kW
24.2A
EPEE63AS
595 x 595 x 573
230-240v/50Hz
16A
3.1kW
12.9A
EOEK62AK
595 x 595 x 567
230-240v/50Hz
16A
3.1kW
12.9A
error code
description
comment
fix
F01 or 01
Door lock sensor alarm
This relates to a door lock
failure which is only associated
with the Pyro product
Check wiring/plugs or
replace door lock
F02 or 02
Door lock actuator alarm
F04 or 04
Oven Probe (PT500) out of
range alarm
This relates to the temperature
sensing probe which may be
out of tolerance, or have open/
short circuit connections
Replace probe
F05 or 05
Oven Probe (PT500) too high
temperature alarm
25
Board Temperature Sensor
(NTC) too high temperature
alarm
This relates to the temperature
of the powerboard and/or the
temperature-sensing element
(NTC) on the powerboard
Cooling fan not working
or replace powerboard
26
Board Temperature Sensor
(NTC) out of range warning
6
Board Temperature Sensor
(NTC) out of range alarm
F08 or 08
Communication alarm
This relates to an error in
communication between
the powerboard and the IOI
controller. This can occur if the
IOI controller is connected while
the powerboard is energised
Reset power. (Minimum of
20 sec.) or check or replace
data cable
F09 or 09
Software compatibility code
alarm
This relates to a mismatch
between powerboard firmware
version and the IOI controller
firmware version. Most likely
caused by an un-programmed
powerboard
Replace Powerboard
C1
Telescopic runners fitted
Only applies to Pyro product
Remove both side racks and
re-start pyro cycle
C3
Door open
Only applies to Pyro product
Close door and restart pyro
cycle
F03 or 03
EEPROM check sum alarm
Relates to the controller
Replace Controller
F14 or 14
EEPROM compatibility code
alarm
Relates to the controller
Replace Controller
EMAN_ELineOven_Aug09.indd 33