DOC. NO. 5956.65J.00

P. 60 / 174

EFS - Dishwashing Systems Platform
Electrolux Professional

AUCAI

PROG 116

1.

Switch OFF and then switch ON the machine.

2.



Enter into CFG parameter family and set the following parameters:



Hood Type and undercounter.



Atmospheric boiler.



Front loading function.



Default values for Undercounter models.



SOFT START enabled.



Tank heater works only if boiler temperature reached.





Enable filling tank by means of rinsing cycles.



Detergent level switches not enabled.



ACTIVE function disabled.



Regeneration cycle disabled (only for dishwashers with non-continuous water softener).



Alarms enabled.



Boiler electronic level sensor.



Resin regeneration cycle forcing.





Rinse water max. hardness.





Boiler heating control.

3.

Switch OFF and then switch ON the machine.

4.

Modify Factory parameters:



Enter into FAC parameter family and set the following parameters.





Boiler Temperature Threshold.





Boiler temperature: alarm threshold.



Boiler Temperature Adjust.



Boiler standby function enabled.



Booster Function.



During stand-by boiler is kept at lower temperature than Temperature Threshold.





Tub Temperature: Threshold.





Tank temperature: alarm threshold.

5.

Modify the cycle parameters:



Cycle 1 parameters family.



Long Wash Phase [min].





Short Wash Phase [s].



Pause [s].





Rinse Phase Duration [s].





Drain [s].



Final Pause [s]. 



Cycle 2 parameters family.



Long Wash Phase [min].





Short Wash Phase [s].



Pause [s].





Rinse Phase Duration [s].





Drain [s].



Final Pause [s]. 



Cycle 3 parameters family.



Long Wash Phase [min].





Short Wash Phase [s].



Pause [s].





Rinse Phase Duration [s].





Drain [s].



Final Pause [s].



Boiler Temperature Threshold for Cycle 3.

Содержание Dishwashing EUC1

Страница 1: ...400132 NUC3DPP 502047 ZUCI 505048 EHTAG 400056 EUC1DP 400133 NUC1D 502048 ZUCID 505049 EHTM 400057 EUC1WS 400134 NUC1DD 502049 ZUCAI 505050 EHTM60 400058 EUC1DPWS 400137 EUCA1DP 502050 ZUCAIDP 505051 NHT 400059 EUC3 400138 NUC1GMS 502051 ZUCAIDPWS 505052 NHTD 400060 EUC3WS 400139 EUC3DPCAG 502052 ZUCAIG 505053 NHT60 400061 EUC3DP 400140 NUC1 502053 ZUCAIDDWS 505054 EHTAROW 400062 EUC3DPWS 400141 N...

Страница 2: ...B 698095 AUCAIG 506071 EPPWESGM6 698096 AUCAIWSG 506073 EPPWESGM 698097 ET12AI 506074 EPPWESG6M 698098 ET12AIT 506075 EPPWEHGM 698110 NHTAG 506076 EPPWELGM 698115 AHTAWS 506077 EPPWELG6M 698116 AHTAIWS 511326 NPPWESG 698117 AHTAIG 511328 NPPWEHG 698118 AHTAIWSG 511329 NPPWELG 698119 AHTA 690028 NUC1G 698120 AHTAI 698005 NUCA1DDG S49LBN 698047 OHTAROW S49QL1 698048 OHTAROW60 698049 NUCA1DPDDG 69805...

Страница 3: ...arameters for automatic hood type dishwashers Pag 19 9 SPECIAL FEATURES Pag 21 9 1 RESIN REGENERATION CYCLE Pag 21 9 2 MEDICAL LINE DISHWASHER WITH DOOR HOOD LOCK DEVICE Pag 21 9 3 DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION Pag 21 9 4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER Pag 22 9 5 HOOD TYPE DISHWASHER WITH CYCLE THERMAL LABEL Pag 23 9 6 DISHWASHERS WITH WASH TANK WATER CHA...

Страница 4: ...e of the two keys Fig 1 Detergent dispenser Manual Activation Fig 2 Rinse Aid Dispenser Manual Activation Fig 3 Rinse Pump Manual Activation used to EMPTY BOILER Fig 4 Enter into General Parameters Hold down buttons for at least five seconds Fig 5 Enter into Factory Parameters Hold down buttons for at least five seconds Fig 6 Next Parameter Family OR Increase Parameter Value In setting mode only F...

Страница 5: ...vation Fig 10 Rinse Aid Dispenser Manual Activation Fig 11 Rinse Pump Manual Activation used to EMPTY BOILER Fig 12 Enter into General Parameters Hold down buttons for at least five seconds Fig 13 Enter into Factory Parameters Hold down buttons for at least five seconds Fig 14 Next Parameter Family OR Increase Parameter Value in setting mode only Fig 15 Decrease Parameter Value In setting mode onl...

Страница 6: ...be used for a long time for maintenance oper ation ex before replacing main board Switch on the dishwasher Press and hold down CYCLE_2 and CYCLE INFINITE keys after two beep the detergent dispenser starts work for 20 sec Switch on the dishwasher Press and hold down CYCLE_1 and CYCLE INFINITE keys after two beep the rinse aid dispenser starts work for 40 sec Switch on the dishwasher Close the door ...

Страница 7: ...ase the duration and CYCLE_2 key to increase Figure 19 After settled the duration press CYCLE_INFINITE key to store value The display shows the next parameter Figure 20 and the corresponding value Figure 21 In the same way is possible to change the other duration when finished switch OFF and switch ON Sym Parameter Description Unit Min Max Factory Default Initial Detergent Dosage during filling ta...

Страница 8: ...inse aid dispenser works when LOADING EV is being activated to re fill boiler level at the same time voltage is supplied between connectors L18 L19 main ter minal box if the rinse aid dispenser works when WASHING PUMP is being activated at the same time voltage is supplied between connectors L18 L19 main terminal box For electrical connections refer to electric diagram Example Suppose there is con...

Страница 9: ...software version 3 12 Counts the litres of water and is resettable by user see parame ter below l Reset resettable counters and To reset put 1 this parameter switch off and then on again and will show zero Note that is used to count cycles for message see next parameter Store thousand of cycles after that message appears on dis play Ex If this parameter is settled to 20 message appears when reach ...

Страница 10: ...EFS Dishwashing Systems Platform Electrolux Professional Fig 26 USER setting mode press for 5s Fig 27 Next Family Fig 28 Counters Fam ENTER Fig 29 CYCLES Fig 30 Thousand Fig 31 Units Fig 32 Next counter GEn GEn Cnt CYC 010 042 cYc ...

Страница 11: ...ng time is longer than alarm appears Put 0 to disable alarm min 0 42 5 Boiler Temperature Adjust C 0 7 4 Boiler Priority enable boiler wait function 0 disabled 1 enabled 0 1 1 Booster Function Overheat gap over Boiler Temperature Threshold C 0 15 2 Boiler temperature negative differential when the dishwasher is in standby boiler threshold becomes Used to save energy during machine inactivity by ke...

Страница 12: ...e 35 Press CYCLE INFITE key to confirm The display shows the next parameter Figure 36 and the corre sponding value Figure 37 In the same way is possible to change the other parameters when finished switch OFF and switch ON At the end the display will show again and by pressing CYCLE_2 key Fig 41 is possible to change cycle duration see paragraph 7 CYCLE SETTING Fig 33 Factory setting mode Fig 34 B...

Страница 13: ...o decrease Figure 47 Press CYCLE_INFINITE key to confirm The display shows the next parameter Figure 48 and the corre sponding value Figure 49 In the same way is possible to change the other parameters After settled all parameters referring Cycle 1 by pressing CYCLE_2 key is possible to change the Cycle 2 parameters Figure 50 Figure 51 and so on Fig 43 Factory setting mode Fig 44 Select next class...

Страница 14: ...14 174 EFS Dishwashing Systems Platform Electrolux Professional 7 1 CYCLE DIAGRAM CYCLE TYME LEGENDA drain wash rinse pause pre rinse final pause rrinse detergent cold rinse rinse aid IPA Ln Sh PA Pr ri cr FP dr rPA dEt rAi ...

Страница 15: ...e Short s 1 60 45 Pause s 0 20 4 Pre rinse Duration s 0 30 0 Rinse Phase Duration s 10 45 16 Cold Rinse Phase Duration s 0 50 0 Drain s 0 40 16 Final Pause at End of Cycle s 0 60 0 Long wash time in mode Thermal Label min 0 60 1 Short wash time in mode Thermal Label s 0 60 12 Sym Parameter Description Unit Min Max Factory Default Wash Phase Long min 0 20 1 Wash Phase Short s 1 60 40 Pause s 0 20 4...

Страница 16: ...oor hood lock device See par 9 2 MEDICAL LINE DISH WASHER WITH DOOR HOOD LOCK DEVICE s 0 60 0 Celsius Fahrenheit selection 0 Celsius 1 Fahrenheit 0 1 0 Rinse Temperature Display Enable rinse temperature probe if installed 0 during rinse phase the display shows boiler temperature 1 during rinse phase the display shows rinse temperature 0 1 0 Pulse Per Litre This parameter must be settled in accordi...

Страница 17: ...the machine This alarm appears in case of malfunctioning in the continuous water softener To facilitate fault finding see par 13 3 ALARMS THAT DON T STOP THE DISHWASHER FOR MODELS WITH INCORPORATED CONTINUOUS WATER SOFTENER Sym Parameter Description Unit Min Max Factory Default Serial Device 0 8N1 1 PC connection DAAS 8E1 7 HACCP network ECAP 8E1 LK485 LK485 board is nec essary 9 Dishwashers with ...

Страница 18: ...can work simultaneously 1 swap enabled tank heating starts only boiler temperature is reached 2 The booster heating elements and the wash pump have prior ity The tank heating element is activated only when the booster has reached the set temperature and the wash pump is not work ing Note disabling this function changes the global electrical power of appliance before enabling this function check av...

Страница 19: ...pty E g the boiler level sensor for machines with incorporated continuous water softener 0 1 0 Forced start of a resin regeneration cycle only for dishwashers with incorporated continuous water softener See paragraph 9 4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER 0 2 0 Max rinse water hardness only for dishwashers with incorpo rated continuous water softener After modifying disconnect ...

Страница 20: ...wering within which the top limit switch must return to the rest position 0 1 s 0 0 s 20 0 s 20 Displays the last alarm code relative to automatic hood type dish washers 0 Parameter only valid for hood type models Hood lifting motor absorption threshold 50 units correspond to a current of approx 1 ampere 0 250 100 ...

Страница 21: ... vary between 3 f 10 f 1 7 d 5 6 d 2 1 e 7 e 9 2 MEDICAL LINE DISHWASHER WITH DOOR HOOD LOCK DEVICE The medical line dishwasher with door hood lock device has a device that prevents door hood opening for the entire duration of the work cycle For the door hood lock to be active the parameter in the family must be set to The dishwasher door hood is locked at the start of a wash cycle and is released...

Страница 22: ...tank filling or wash cycles even after replen ishing the salt as the salt must circulate in the entire system This however does not affect correct dishwasher operation The number of regeneration cycles performed can be checked by consulting the parameter in the family of counters only counts regeneration cycles carried out with the salt container adequately filled there is another counter in the f...

Страница 23: ...ductivity mode This means that the machine can work in 2 modes high productivity and Thermal Label When the machine is set in high productivity mode the parameters which define the cycle times and temperature set points are the standard parameters whereas when the machine is set in Thermal Label mode the parameters are dedicated they are new parameters listed below The mode Thermal Label provides ...

Страница 24: ...tank water change reaches the value contained in the parameter Cycles before drain the display shows the message at the start of a wash cycle and the message at the end of the same cycle When these messages appear on the display at the start and end of the wash cycle a tank water drain cycle must be done to ensure washes with sufficiently clean water WARNING If the tank drain cycle is not done the...

Страница 25: ...be of the suction part turning the roller clockwise 3 Keep the tube in the seat in the housing and continue turning the roller clockwise being careful not to damage the tube 4 Keep the tube in the seat in the housing and con tinue turning the roller clockwise 5 Turn the roller a full 360 6 Make sure to fit the union in the special seat deliv ery ...

Страница 26: ...ems Platform Electrolux Professional STEP 2 REMOVING THE TUBE 1 Position the roller as shown in the figure 2 Lift the tube at the suction part and turn the roller at the same time Guide the tube keeping it raised and turn the roller 3 Remove the tube ...

Страница 27: ...134 16 ZUCADDROW6 400067 134 16 EUCADD60 400068 143 16 ZUC3DP 400069 103 16 ZUC3DD 400070 103 16 ZUC3DPWS 400071 104 17 ZUC3DDWS 400072 104 17 EUC1G 2 400073 105 11 EUA1DDG 400074 136 16 EUC1DP60 400075 101 11 ZUC1DP60 400076 101 11 EUC1GMS 400077 137 11 ZUC1G 400078 105 11 ZUCA1DDG 400079 136 16 ZUC1GMS 400080 137 11 VUC1 400081 101 11 VUC3 400082 103 16 VUC3G 400083 103 16 VUCA3WSG 400084 163 17...

Страница 28: ...J6M 502066 169 8 EUCIDDC 502123 145 16 ZUCIDC 502124 145 16 EHTA 504226 120 1 EHTA60 504227 120 1 EHTAWS 504228 121 4 MODEL CODE Prog Layout EHTAI 504229 120 1 EHTAID 504230 120 4 EHTAIWS 504231 121 4 EHTAIDWS 504232 121 4 EHTAIG 504233 120 4 EHTAIWSG 504234 121 4 EHTAIAU 504235 122 15 EHTAIMLAU 504236 123 4 ZHTAWS 504237 121 4 ZHTAID 504238 120 4 ZHTAIWS 504239 121 4 ZHTAIAU 504240 122 15 ZHTA 50...

Страница 29: ...HTDPDDG 698058 119 23 APPWELG 698083 140 4 APPWESG 698085 139 4 APPWEHG 698086 139 4 ET5AIIT 698087 131 8 ET5AIDP 698088 132 8 ET5AIDPWS 698089 133 8 Up to Ser Nr 6361 ET5AIDPWS 698089 155 8 From Ser Nr 6371 AUCI 698091 114 16 AUCAI 698092 116 8 AUCAIDP 698093 116 8 AUCAIDPWS 698094 117 8 AUCAIG 698095 106 8 AUCAIWSG 698096 107 8 ET12AI 698097 129 4 ET12AIT 698098 130 4 NHTAG 698110 119 23 AHTAWS ...

Страница 30: ...se water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold ...

Страница 31: ...ng mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters...

Страница 32: ...er max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Te...

Страница 33: ...Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine...

Страница 34: ...r heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Threshold T...

Страница 35: ...ning mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following paramete...

Страница 36: ...iler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Threshol...

Страница 37: ...Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine...

Страница 38: ...ax hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temper...

Страница 39: ...ing mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameter...

Страница 40: ...hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperatu...

Страница 41: ...ontrol disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter family an...

Страница 42: ...e forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperatu...

Страница 43: ...sh tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Dishwashe...

Страница 44: ... max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Disable boiler high Temperature alarm Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub T...

Страница 45: ...ank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arran...

Страница 46: ...ax hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Disable boiler high Temperature alarm Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Tem...

Страница 47: ...water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Dishwasher with i...

Страница 48: ... Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Disable boiler high Temperature alarm Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Thr...

Страница 49: ...ank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arran...

Страница 50: ... Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Thresh...

Страница 51: ...ank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arran...

Страница 52: ...ng Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Thre...

Страница 53: ...ank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arran...

Страница 54: ...g Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Thres...

Страница 55: ...ank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arran...

Страница 56: ...er max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Te...

Страница 57: ...h tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine ar...

Страница 58: ...on cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Disable boiler high Temperature alarm Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than...

Страница 59: ...nk water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arrang...

Страница 60: ... max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temp...

Страница 61: ...nk water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arrang...

Страница 62: ...g Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Thres...

Страница 63: ...water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Dishwasher with i...

Страница 64: ...Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Thresho...

Страница 65: ... tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arr...

Страница 66: ...g Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Thres...

Страница 67: ...tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arra...

Страница 68: ...ion cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than T...

Страница 69: ...l disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter family and set...

Страница 70: ...ion cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than T...

Страница 71: ...tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Dishwasher w...

Страница 72: ...ation cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than...

Страница 73: ...sh tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine a...

Страница 74: ... cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Disable boiler high Temperature alarm Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than T...

Страница 75: ...tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arra...

Страница 76: ...ation cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Disable boiler high Temperature alarm Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature t...

Страница 77: ...rain Phase Duration s Drain and cleaning mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode enabled ...

Страница 78: ... cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temp...

Страница 79: ...nk water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees display Fahrenheit During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arr...

Страница 80: ... cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temp...

Страница 81: ...nk water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees display Fahrenheit During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arr...

Страница 82: ... cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Disable boiler high Temperature alarm Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than T...

Страница 83: ...n s Final Drain Phase Duration s Drain and cleaning mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mo...

Страница 84: ... Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Thres...

Страница 85: ...k water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arrange...

Страница 86: ... water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tu...

Страница 87: ...uency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter fa...

Страница 88: ...e water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold T...

Страница 89: ...uency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter fa...

Страница 90: ... control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Threshold Tank tempe...

Страница 91: ...ing mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameter...

Страница 92: ...ch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Threshold Tank temperature alarm th...

Страница 93: ...Duration s Final Drain Phase Duration s Drain and cleaning mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature 6 Switch...

Страница 94: ... control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Threshold Tank tempe...

Страница 95: ...mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Di...

Страница 96: ...r heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Threshold T...

Страница 97: ...Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine...

Страница 98: ...eating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Threshold Tank...

Страница 99: ...ank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arran...

Страница 100: ...s Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Thre...

Страница 101: ...ode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Mac...

Страница 102: ...x hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Tempera...

Страница 103: ...ing mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameter...

Страница 104: ...ting control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Threshold Tank t...

Страница 105: ...ber of wash cycles possible between one drain cycle and the next Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following par...

Страница 106: ...ion cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than T...

Страница 107: ...bled Drain cycle Timeout Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter ...

Страница 108: ...ion cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than T...

Страница 109: ...bled Drain cycle Timeout Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter ...

Страница 110: ...ion cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than T...

Страница 111: ...bled Drain cycle Timeout Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter ...

Страница 112: ...ion cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than T...

Страница 113: ...bled Drain cycle Timeout Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter ...

Страница 114: ...vel sensor Resin regeneration cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept a...

Страница 115: ...tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arra...

Страница 116: ... max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Disable boiler high Temperature alarm Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tank ...

Страница 117: ...se Duration s Drain and cleaning mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Boiler ...

Страница 118: ...el sensor Resin regeneration cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at...

Страница 119: ...family Initial Drain Phase Duration s Final Drain Phase Duration s Drain and cleaning mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the ...

Страница 120: ...neration cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature t...

Страница 121: ...KP PROG 146 Drain parameters family Initial Drain Phase Duration s Final Drain Phase Duration s Drain and cleaning mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse...

Страница 122: ...on cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Te...

Страница 123: ...led Drain cycle Timeout Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter f...

Страница 124: ...cle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Tempera...

Страница 125: ...rain cycle Timeout Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter family...

Страница 126: ...e forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperatu...

Страница 127: ... tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Dishwasher ...

Страница 128: ...ing control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Threshold Tank te...

Страница 129: ... mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters D...

Страница 130: ...r max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Disable boiler high Temperature alarm Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub ...

Страница 131: ...water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Dishwasher with i...

Страница 132: ...cing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Th...

Страница 133: ... water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Dishwasher with ...

Страница 134: ...cing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Th...

Страница 135: ... water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Dishwasher with ...

Страница 136: ...el sensor Resin regeneration cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at...

Страница 137: ...ank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arran...

Страница 138: ...eating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Threshold Tank...

Страница 139: ...tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machine arra...

Страница 140: ...ectronic level sensor Resin regeneration cycle forcing Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boile...

Страница 141: ...isabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter family and set th...

Страница 142: ...ting control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Threshold Tank t...

Страница 143: ... mode Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters M...

Страница 144: ...ng Rinse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Thre...

Страница 145: ...ed Drain cycle Timeout Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter fa...

Страница 146: ...inse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshol...

Страница 147: ...rain cycle Timeout Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter family...

Страница 148: ...inse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshol...

Страница 149: ...rain cycle Timeout Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter family...

Страница 150: ...ler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Threshold...

Страница 151: ... control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter family ...

Страница 152: ...er heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshold Tub Temperature Threshold ...

Страница 153: ... Wash tank water change frequency control disabled Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Enter into HCP parameter family and set the following parameters Machin...

Страница 154: ...inse water max hardness Boiler heating control 3 Switch OFF and then switch ON the machine 4 Modify Factory parameters Enter into FAC parameter family and set the following parameters Boiler Temperature Threshold Boiler temperature alarm threshold Boiler Temperature Adjust Boiler standby function enabled Booster Function During stand by boiler is kept at lower temperature than Temperature Threshol...

Страница 155: ...rain cycle Timeout Set other parameters Initial Pause s for ALL cycles Delay for the 2nd wash pump s Drain Phase Duration at the end of washing phase s Duration of pause after the rinse cycle s for ALL cycles Degrees Celsius display During the rinse stage the display shows the boiler temperature Termal Label mode disabled Functions present with firmware version 4 04 Enter into HCP parameter family...

Страница 156: ...DOC NO 5956 65J 00 P 156 174 EFS Dishwashing Systems Platform Electrolux Professional 11 DEFAULT VALUES Default 1 HOOD TYPE ON OFF CYCLE1 keys ON OFF CYCLE2 keys ...

Страница 157: ...DOC NO 5956 65J 00 P 157 174 EFS Dishwashing Systems Platform Electrolux Professional Default 2 POT WASHER ON OFF CYCLE1 keys ON OFF CYCLE2 keys ...

Страница 158: ...DOC NO 5956 65J 00 P 158 174 EFS Dishwashing Systems Platform Electrolux Professional Default 3 UNDERCOUNTER ON OFF CYCLE1 keys ON OFF CYCLE2 keys ...

Страница 159: ...ser interface inputs outputs CN15 Overflow tank level board feed input CN16 User interface inputs outputs and hood door sensor input The display shows with door hood closed Check door hood micro sensor No cycle starts Check the user interface buttons have they remained pressed etc A cycle fails to start Is a user interface button extension missing After replacing the main board only the 3rd cycle ...

Страница 160: ...sor inputs CN7 Hand safety system microswitch input CN8 Energy peak controller input CN10 Safety and upper lower limit switch input CN11 Hand safety system input Gear motor current control input Gear motor polarity inversion connection CN12 User interface inputs outputs CN15 Overflow tank level board feed input CN16 User interface inputs outputs and hood door sensor input LAYOUT 4 ZHTA AHTA EHTA Z...

Страница 161: ...tergent rinse aid dispenser and drain pump outputs CN5 Tank boiler temperature sensor inputs CN8 Energy peak controller input CN11 Door lock electromagnet output CN12 User interface inputs outputs CN15 Overflow tank level board feed input CN16 User interface inputs outputs and hood door sensor input CN17 Door microswitch connector LAYOUT 10 EUCIM EUCAIMLG LAYOUT 11 NUC1 EUC1 ZUCA1 NUC1 EUC1 ZUCA1 ...

Страница 162: ...lve connection CN3 ECOTEMP transformer detergent rinse aid dispenser and drain pump outputs CN5 Tank boiler temperature sensor inputs CN8 Energy peak controller input CN11 Hood lock electromagnet output CN12 User interface inputs outputs CN15 Overflow tank level board feed input CN16 User interface inputs outputs and hood door sensor input LAYOUT 15 ZHTAAU EHTAAU LAYOUT 13 NHT EHT KHT ...

Страница 163: ...nputs CN8 Energy peak controller input CN9 Salt receptacle drain pump and low pressure solenoid valve outputs CN11 Brine solenoid valve output CN12 User interface inputs outputs CN15 Overflow tank level board feed input CN16 User interface inputs outputs and hood door sensor input CN17 Door microswitch connection LAYOUT 16 NUC EUC ZUCI AUCI EUCI ZUCA3 FUCA3DD NUCA1DDG KUC ZUCADDROW EUCADDROW LAYOU...

Страница 164: ...ction CN3 Detergent rinse aid dispenser and drain pump outputs CN5 Tank boiler temperature sensor inputs CN7 Detergent rinse aid level sensors input CN8 Energy peak controller input CN12 User interface inputs outputs CN15 Overflow tank level board feed input CN16 User interface inputs outputs and hood door sensor input CN17 Door microswitch connection LAYOUT 18 EUCAICL LAYOUT 19 EUCIM EUCIM60 ...

Страница 165: ...rain pump outputs CN5 Tank boiler temperature sensor inputs CN8 Energy peak controller input CN9 Salt receptacle drain pump and low pressure solenoid valve outputs CN11 Brine solenoid valve output CN12 User interface inputs outputs CN15 Overflow tank level board feed input CN16 User interface inputs outputs and hood door sensor input CN17 Door microswitch connection LAYOUT 21 NUC1WS EUC1WS LAYOUT ...

Страница 166: ... filter clean Is the overflow inserted Is the main board ATM PRES CN2 connector correctly positioned Do the tank boiler pressure switches work properly Rinsing is not done regularly for 2 consecutive cycles Are the rinse arms clogged Does the rinse pump work correctly Is there water in the level sensor tube Is there scale in the boiler Does the boiler level sensor work properly ONLY FOR MACHINES W...

Страница 167: ...t switch S3 must return to the rest position within a time given by the parameter otherwise the alarm appears S3 could be stuck S5 could be disconnected On installation this alarm can occur due to incorrect sequence of the phases invert the two phases on the power supply terminal board Appears if during lifting S3 does not return to the rest position within a time Appears if the bottom limit switc...

Страница 168: ...tor works b Polarity motor rotation direction inverted During the initial lowering phase the top limit switch S5 must return to the rest position within a time given by the parameter oth erwise the alarm appears S5 could be stuck S3 could be disconnected On installation this alarm can occur due to incorrect sequence of the phases invert the two phases on the power supply terminal board Appears if ...

Страница 169: ...ng combina tions occurs top limit switch S5 and bottom limit switch S3 both activated S3 and S5 could be dis connected top limit switch S5 and S3 both cut in bottom limit switch S3 cut in but not S3 During lifting the current absorbed by the lifting motor has exceeded the threshold see parameter a excessive mechanical force during lifting During lowering the current absorbed by the lifting motor h...

Страница 170: ...essure switch clean Does the tank pressure switch work properly Is the load solenoid valve blocked E1 LOAD_EV Is the load solenoid valve relay stuck RL8 LOAD_EV Θ Boiler temperature rise too fast Does the boiler level sensor work properly The boiler could be empty Are non original power resistances installed Θ Boiler temperature too high Has the boiler temperature been changed increased above 90 C...

Страница 171: ...emperature sensor on the rinse circuit Is the temperature sensor short circuited Communication error Is the connection between main board and control panel correct Are the connectors correctly connected Are connector contacts clean Tank temperature low Does the tank heating element work properly Are the connectors correctly connected Are the dishwasher feed voltage and current correct Is the relay...

Страница 172: ...been eliminated Alarm is reset when the machine is switched off and on from the user interface or from the main switch only if the causes that generated it have been eliminated Θ Water softener operation errors This alarm appears in case of malfunctioning in the continuous water softener To reset error it is necessary to disconnect and reconnect the main power supply to the machine by means of the...

Страница 173: ...x filling time Make sure the water cock is open the water filling solenoid valve works correctly the salt container solenoid valve works correctly the feed water pressure is at least 50 kPa 0 5 bar the water inlet filter is clean the filling solenoid valve filter is clean the salt container cap is properly closed the mother board ATM PRES connector CN2 is correctly positioned the water softener bo...

Страница 174: ...DOC NO 5956 65J 00 P 174 174 EFS Dishwashing Systems Platform Electrolux Professional ...