DESCRIPTION OF YOUR RANGEHOOD

RANGEHOOD DIMENSIONS

56mm

500mm

320mm

900mm

1135mm (maximum)
690mm (minimum)

290mm

538mm

Fig. 4

1

2

3

4

5

6

7

8

Components list

1. Screws x 2

2. Telescopic flue cover set

3. Flexible flue pipe

4. Upper flue cover mounting bracket

5. Lower flue cover mounting bracket

6.  Flue transition duct

7. Main body and fan housing assembly

8. Grease filters

Additional items required for installation

• Fixings required to attach rangehood body and 

anti tilt points.

• Fixings required to attach flue cover mounting 

brackets to the wall.

• Duct tape or cable ties. 

Technical specifications

Height

69-113.5cm

Width

90cm

Depth

50cm

Maximum absorbed power

330W

Lighting

2 x 50W

Outlet diameter

150mm

Electrical connection

220-240V, 50Hz

The manufacturer reserves the right to effect any 

technological improvement or modification without  

prior notice.

150mm

NOTE: The fan housing flue transition duct is 150mm in diameter.

(See page 13 for optional ducting accessories).

Fig. 5

Fig. 3

User manual_CS910CS

28/11

/2012

MODEL

CS910CS

Содержание CS910CS

Страница 1: ...action Keep exhaust flue short and straight Do not reduce the size or restrict exhaust flue Keep bends in the exhaust flue to a minimum When using flexible flue always install duct with helix pulled taut to minimise pressure loss Failure to observe these basic instructions will drastically reduce the performance and increase the noise levels of the cooker hood Exhaust air must not be discharged in...

Страница 2: ... Fixings required to attach rangehood body and anti tilt points Fixings required to attach flue cover mounting brackets to the wall Duct tape or cable ties Technical specifications Height 69 113 5cm Width 90cm Depth 50cm Maximum absorbed power 330W Lighting 2 x 50W Outlet diameter 150mm Electrical connection 220 240V 50Hz The manufacturer reserves the right to effect any technological improvement ...

Страница 3: ...step 6a or 6b below 6a Recirculating mode Fig 9 Using the centre line secure the recirculating T piece to the wall with suitable screws fixings optional kit AR910RK Install flexible pipe between T piece and the exhaust transition duct Use cable ties or suitable duct tape to secure flexible pipe to T piece and transition duct Fig 11 NOTE When installed in recirculating mode it is recommended to use...

Страница 4: ...ess steel surfaces using non abrasive cleaning products that are specifically for use on stainless steel To ensure best results also use an even pressure and follow the grain of the stainless steel Use of a soft cloth reduces the risk of scratching If the cloth is wet ensure that a dry soft cloth is used to wipe down the surface again reducing the risk of any surface rust appearing Never use corro...

Страница 5: ...d is set high enough for the task The grease filters are clean The kitchen is adequately vented to allow the entry of fresh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The cooker hood has switched off during operation The safety cut out device has been tripped turn off the hob and wait...

Страница 6: ...er installation vi incorrect improper or inappropriate operation vii insect or vermin infestation viii failure to comply with any additional instructions supplied with the Appliance b the Appliance is modified without authority from Electrolux in writing c the Appliance s serial number or warranty seal has been removed or defaced d the Appliance was serviced or repaired by anyone other than Electr...

Отзывы: