11
E
NORMAL USE
E.1
Correct use
Our machines are designed and optimized in order to obtain
high performance and efficiency.
This equipment must only be used for its expressly designed
purpose, i. e. washing dishes with water and specific deter-
gents. Any other use is to be deemed improper.
E.2
Characteristics of personnel enabled to
operate on the machine
The Customer is responsible for ensuring that persons
assigned to the various duties:
• read and understand the manual;
• receive adequate training and instruction for their duties in
order to perform them safely;
• receive specific training for correct machine use.
E.3
Characteristics of personnel trained for
normal machine use
The Customer must make sure the personnel for normal
machine use are adequately trained and skilled in their duties,
as well as ensuring their own safety and that of other persons.
The Customer must make sure his personnel have understood
the instructions received and in particular those regarding work
hygiene and safety in use of the machine.
E.4
Operator qualified for normal machine
use
Must have at least:
• knowledge of the technology and specific experience in
operating the machine;
• adequate general basic education and technical knowledge
for reading and understanding the contents of the manual,
including correct interpretation of the drawings, signs and
pictograms;
• sufficient technical knowledge for safely performing his
duties as specified in the manual;
• knowledge of the regulations on work hygiene and safety.
In case of a significant anomaly (e. g. short circuits, wires
coming out of the terminal block, motor breakdowns, worn
electrical cable sheathing, etc.) the operator for normal
machine use must:
• immediately deactivate the machine by turning the switch
disconnector to “O“ or operating the main emergency switch
on the equipment;
• close the machine water supply by shutting off the water.
F
TECHNICAL DATA
F.1
Main technical characteristics for single phase appliances
Model
EL1...
ZL1...
NL1...
VL1...
CL1...
CL1G
EL1G
ZL1G
NL1G
VL1G
EL1P6
EL1G6M
ELA1W
ELA1WP
ELA1P
CLA1G
ELA1G
NLA1G
ZLA1G
ELA1G6
Supply voltage:
230V 1N~
230V 1N~
220 - 230V
1N~ [Only for
model EL1P6]
230V 1N~
230V 1N~
220 - 230V
1N~
230V 1N~
Convertible to:
-
-
-
-
400V 3N~
230V 3~
380 - 400V
3N~
220 - 230V 3~
Frequency
Hz
50
50
60
50
50
60
Max. power
kW
3.65 [5.65]
1
2.85 [4.35]
3.65 [5.65]
3.65 [5.65]
5.35 [7.35]
5.35 [7.35]
2.35 [Only
for model
CL1GU]
3.65 [5.65]
[Only for
model
CL1G]
3.65 [5.65]
[Only for
model
NLA1G]
3.65 [Only
for model
NL1PPR]
5.35 [Only
for model
NLA1G]
Boiler heating
elements
kW
2.8
1.5
2.8
2.8
4.5
4.5
1.5 [Only for
model
CL1GU]
2.8 [Only for
model
CL1G]
Tank heating
elements
kW
2.0
2.0
2.0
2.0
2.0
2.0
Water supply
pressure
bar
[kPa]
2 [200]
3 [300]
2 [200]
3 [300]
2 [200]
3 [300]
0.5 [50]
7 [700]
0.5 [50]
7 [700]
0.5 [50]
7 [700]
Water supply
temperature
℃
50
50
50
50
50
15 - 60
Water supply
hardness
°f/°d/°e
14/8/10
max
14/8/10
max
14/8/10 max
48/27/33.7
max
[14/8/10 max]
2
14/8/10 max
14/8/10 max