background image

Dimensions and Installation Information (in inches) 

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

geappliances.com or call GE Answer Center

®

 

service, 800.626.2000.

As an EnErgy StAr

®

 

partner, gE has determined 

that this product meets the 

EnErgy StAr guidelines 

for energy efficiency.

Specification Created 5/11

350278

Panel 

Thickness

Kit

A

B

C

GPF525

25-1/4"

23-1/2"

N/A

1/4"

GPF575

25-1/2"

23-5/8"

1/4"

3/4"

Listed by 

Underwriters 

Laboratories

• The rough cabinet opening must be at least 24" deep,

24" wide and approximately 34-1/2" high from floor to
underside of the countertop.

 

 

 

 

 

 

 

   

 

4"

6"

5"

5"

4"

Figure A

Floor MUST be Even

With Room Floor

Cabinets

Square

and

Plumb

This Wall Area

must be Free

of Pipes or

wires

24"

Min.

24"

Min.

34-1/2"

Underside of

Countertop

to Floor

Plumbing and Electric Service

Must Enter Inside This Area

24

 25

MAX. 

20-1/2

4

4 (Adjustable)

33-3/4" MIN.

adj. to 35"

27-1/2

22

B

See Detail E for 3/4" Panel

Detail E for 3/4 panel only

Door insert

A

Back View

Front View

F
F

1-7/8

1-7/8

20

Section E-F

C

3/8

3/4

B

See Detail E for 3/4" Panel

Detail E for 3/4 panel only

Door insert

A

Back View

Front View

F
F

1-7/8

1-7/8

20

Section E-F

C

3/8

3/4

Electrical Rating 
Voltage AC..........................................................  120 
Hertz.....................................................................    60 
Total connected load amperage.............    10 
Calrod® heater watts max........................   875
For use on adequately wired 120-volt,  
15-amp circuit having 2-wire service  
with a separate ground wire. This appliance 
must be grounded for safe operation.
Note: The rough cabinet opening must be at 
least 24" deep, 24" wide and approximately 
34-1/2" high from floor to underside of 
the countertop. Dishwasher must not be 
installed more than 10 feet from sink for 
proper drainage. All plumbing and  
electrical work must be in accordance  
with local codes. The power cord and  
connections must comply with the National 
Electrical Code Section 422 and/or local 
codes and ordinances. The cord must be no 
longer than 6 ft. from the junction box to  
the receptacle.
Installation Information: Before installing,  
consult installation instructions packed with 
product for  current dimensional data.

GLD5600/60V 

GE

®

 Tall Tub Built-In Dishwasher

 

Отзывы: