15
Fitting the Hood Body
Before starting to fi x the hood body, tighten
the two screws Vr located on the top of the
hood body.
Hook the hood body onto the two screws
item 12a
(not supplied).
Fully tighten the screws
item 12a
.
Using a screw driver and spirit level, adjust
the screws
item Vr
until the hood body is
level.
Extraction
The cooker hood is more effective when used in the
extraction mode (ducted to the outside).
Venting kits may be purchased through your
retailer or DIY store, and must be ducted to an
outside vent of
Ø
125mm (5”) or
Ø
150mm (6”).
The ducting used must be manufactured from fi re
retardent material conforming to the relevant British
Standard or DIN 4102-B1.
When the cooker hood is ducted to the outside the
charcoal fi lter must be removed.
Recirculation
The cooker hood is supplied specifi ed for use in the
recirculation mode, with the charcoal fi lter fi tted.
In the recirculation mode contaminated air is
passed through the charcoal fi lter to be purifi ed
and recirculated into the kitchen through the grille
outlets on either side of the chimney.
To assemble the recirculation duct, place the
recirculation outlet connection
item 15
into the
support
item 7.3
.
Insert the extension ducts
item 14.1
into either
side of the recirculation outlet
item 15
ensuring the
connections are vertically and horizontally aligned
with the outlets in the chimney.
Connect the recirculation oulet
item 15
to the outlet
on top of the hood body using either a piece of
Ø125mm or Ø150mm fl exible or rigid pipe.
Rigid pipe is strongly recommended and should be
used where possible as this will ensure the best
performance while lowering noise.
ø 150
14.1
15
12a
Vr
INSTALLING THE COOKER HOOD