Problem
Possible cause
Solution
Water flows on the rear
plate of the refrigerator.
During the automatic defrosting
process, frost defrosts on the rear
plate.
This is correct.
Water flows into the re-
frigerator.
The water outlet is clogged.
Clean the water outlet.
Products prevent that water flows
into the water collector.
Make sure that products do not
touch the rear plate.
Water flows on the
ground.
The melting water outlet does not
flow in the evaporative tray above
the compressor.
Attach the melting water outlet to
the evaporative tray.
The temperature in the
appliance is too low.
The temperature regulator is not
set correctly.
Set a higher temperature.
The temperature in the
appliance is too high.
The temperature regulator is not
set correctly.
Set a lower temperature.
The door is not closed correctly.
Refer to "Closing the door".
The product temperature is too
high.
Let the product temperature de-
crease to room temperature before
storage.
Many products are stored at the
same time.
Store less products at the same
time.
There is no cold air circulation in
the appliance.
Make sure that there is cold air cir-
culation in the appliance.
Replacing the lamp
1. Disconnect the mains plug from the
mains socket.
2. Remove the screw from the lamp cover.
3. Remove the lamp cover (refer to the illus-
tration).
4. Replace the used lamp with a new lamp
of the same power (the maximum power
is shown on the lamp cover).
5. Install the lamp cover.
6. Tighten the screw to the lamp cover.
7. Connect the mains plug to the mains
socket.
8. Open the door. Make sure that the lamp
comes on.
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "In-
stallation".
3. If necessary, replace the defective door
gaskets. Contact the Service Force Cen-
ter.
10
electrolux
Содержание ARA34280W
Страница 1: ...user manual Refrigerator ARA34280W ...
Страница 15: ...electrolux 15 ...
Страница 16: ...212700331 00 03042009 www electrolux com ...