air-o-steam
Touchline
Natural Gas Combi Oven 201
air-o-steam
Touchline Natural Gas Combi Oven 201
The company reserves the right to make modifications to the products
without prior notice. All information correct at time of printing.
2012.09.28
Front
Top
CWI
= Cold Water inlet
D
= Drain
EI
= Electrical connection
G
= Gas connection
Side
Electric
Supply voltage:
267704(AOS201GTG1)
230 V/1N ph/50/60 Hz
Circuit breaker required
Gas
ISO 7/1 gas connection diameter:
1" MNPT
Natural gas:
Pressure:
7" w.c. (17.4 mbar)
Steam generator:
25 kW
Heating elements:
136360 BTU (40 kW)
Total thermal load:
197722 BTU (58 kW)
Water:
Water inlet "CW" connection:
3/4"
Water inlet "FCW" connection:
3/4"
Total hardness:
5-50 ppm
Pressure:
1.5-4.5 bar
Pressure:
15-36 psi (1.5-4.5 bar)
Drain "D":
1"1/4
Electrolux
recommends the use of treated water, based on
testing of specific water conditions.
Please refer to user manual for detailed water quality
information.
Installation:
Clearance:
5 cm rear and right hand sides.
Suggested clearance for service
access:
50 cm left hand side.
Capacity:
GN:
20 - 1/1 Gastronorm
Max load capacity:
100 kg
Key Information:
External dimensions, Height:
1795 mm
External dimensions, Width:
993 mm
External dimensions, Depth:
957 mm
Net weight:
312 kg
Shipping weight:
340 kg
Shipping volume: