17
Summary table of the Personal Protection Equipment (PPE) to be used during the various stages of the machine's
service life. (cont'd.)
Stage
Protective
garments
Safety footwear
Gloves
Glasses
Safety helmet
Dismantling
○
●
○
○
—
Scrapping
○
●
○
○
—
Key:
●
PPE REQUIRED
○
PPE AVAILABLE OR TO BE USED IF NECESSARY
—
PPE NOT REQUIRED
1.
During these operations, gloves must be cut-resistant. Failure to use the personal protection equipment by operators, specialized personnel or users can
involve exposure to damage to health (depending on the model).
2.
During these operations, gloves must be heatproof and suitable for contact with water and the substances used (refer to the safety data sheet of the
substances used for the information regarding the required PPE). Failure to use the personal protection equipment by operators, specialised personnel or
users can involve exposure to chemical risk and cause possible damage to health (depending on the model).
3.
During these operations, gloves must be suitable for contact with chemical substances used (refer to the safety data sheet of the substances used for
information regarding the required PPE). Failure to use the personal protection equipment by operators, specialized personnel or users can involve exposure
to chemical risk and cause possible damage to health (depending on the model).
C
TECHNICAL DATA
C.1
Main technical characteristics
Model
NHT8/EHT8/
KHT8/HHT8/
XHT8/ZHT8/
VHT7/
ZHT8I/AHT8I/
EHT8I/NHT8I/
HHT8I/XHT8I/
VHT7I/
EHT8M/
EHT8IUSPH5
EHT8M6/
EHT8IUSPH6
EHT8TIL/
ZHT8TIL
Supply voltage:
convertible to
single-phase version
400V 3N~
230V 3~
230V 1N~
400V 3N~
1
230V 3~
230V 1N~
400V 3~
—
—
440V 3~
—
—
400V 3N~
230V 3~
230V 1N~
Frequency
Hz
50
50 or 60
50
60
50
Max. power
kW
12.9
2
12.9
12.9
12.9
12.9
Power absorbed as factory
setting
9.9
9.9
9.9
9.9
9.9
Power absorbed with water
supply at 65
℃
[149
℉
]
6.9
3
6.9
—
—
6.9
Boiler heating elements
kW
9.0
9.0
9.0
9.0
9.0
Tank heating elements
kW
3.0
3.0
3.0
3.0
3.0
Water supply pressure
kPa
[bar]
50 - 700
[0.5 - 7]
50 - 700
[0.5 - 7]
50 - 700
[0.5 - 7]
50 - 700
[0.5 - 7]
50 - 700
[0.5 - 7]
Water supply temperature:
℃
[
℉
]
— for models without ESD
10-65 [50-149]
10-65 [50-149]
10-65 [50-149]
10-65 [50-149]
10-65 [50-149]
— for models with ESD
—
10-20 [50-68]
—
—
10-20 [50-68]
Water supply hardness for
models without incorpo-
rated continuous water
softener
°f/°d/
°e
14/8/10 max
14/8/10 max
14/8/10 max
14/8/10 max
14/8/10 max
Water supply hardness for
models with incorporated
water softener
°f/°d/
°e
53.4/30/
35.7 max
53.4/30/
35.7 max
53.4/30/
35.7 max
53.4/30/
35.7 max
53.4/30/
35.7 max
Electric conductivity of
water for models without
incorporated continuous
water softener
μS/
cm
<400
<400
<400
<400
<400
Concentration of chlorides
in water
ppm
<20
<20
<20
<20
<20
Rinse cycle water
consumption
l
2.0
4
2.0
2.0
2.0
2.0
Boiler capacity
l
12
12
12
12
12
Tank capacity
l
24
24
24
24
24
Содержание AHT8I
Страница 5: ...5 Installation diagram Manual hood type single skin with drain pump and with Energy Saving Device ESD ...
Страница 7: ...7 Installation diagram Manual hood type double skin with drain pump and with Energy Saving Device ESD ...
Страница 8: ...8 Installation diagram Automatic hood type with drain pump and without Energy Saving Device ESD ...
Страница 9: ...9 Installation diagram Automatic hood type with drain pump and with En ergy Saving Device ESD ...
Страница 39: ......
Страница 40: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electrolux professional com ...