10
Drain Pump Connection
CONNECTING A DRAIN PUMP
If a gravity drain connection is not available, and you have not purchased the
E15IM60E with factory installed pump, we strongly recommend the use of the
Electrolux EIMP60 drain pump. The Electrolux EIMP60 drain pump is available
through your Dealer, or direct from Electrolux with complete installation instructions.
If a pump other than the Electrolux EIMP60 drain pump is to be used, it must meet
the following specifications:
•
It must be UL listed and have a UL listed, 120 VAC, 3-wire grounded power
cord.
•
It must have overall maximum outside dimensions of 8-3/4" wide x 5-3/4"
deep x 7-3/4" high.
•
It must have a minimum flow rate of 15 gallons per hour at 10 feet of lift.
•
It must have a sealed sump which does not allow water leakage in the case
of a power outage, restricted drain or pump failure.
•
It must have a check valve in the discharge line to prevent waste water return
to the pump.
•
It must have an overflow protection control which will shut off power to the ice
maker in the event of a pump failure.
•
It must have an operating temperature range of 50°F to 110°F (10°C to 43°C).
!
CA
CA
CA
CA
CAUTION
UTION
UTION
UTION
UTION
In the event of a power outage, restricted drain or pump failure, the failure to use the
Electrolux EIMP60 drain pump or a pump with the above listed specifications, could
result in substantial water leakage and pooling with severe and costly water damage
and related consequential damages and harm.