30
Storage, Vacation and Moving
DRAINING FOR NON-USE
If the unit is to be stored, moved or not used for extended periods, it will be
necessary to drain the system of water.
1
Disconnect power from the unit.
2
Remove ice from the storage bin.
3
Shut off water supply at the main water source.
4
Disconnect the inlet and outlet lines to the water valve and allow them to
drain.
5
Reconnect inlet and outlet lines to the water valve.
6
Replace back panel.
7
Drain water from the water trough and drain line by removing the overflow
tube (see
Figure 34
).
8
Clean the ice maker and storage bin before next use.
9
Prop door open to allow for air circulation and prevent mold and mildew.
!
WARNING
WARNING
WARNING
WARNING
WARNING
Electrical Shock Hazard. Disconnect power before servicing. Before operating replace
all panels. Failure to do so can result in death or electrical shock.
!
CA
CA
CA
CA
CAUTION
UTION
UTION
UTION
UTION
If the ambient temperature is expected to drop below 45°F (7°C), drain all water from the
unit to prevent freezing damage, which is not covered by the warranty.
IMPOR
IMPOR
IMPOR
IMPOR
IMPORT
T
T
T
TANT
ANT
ANT
ANT
ANT
The use of anti-freeze or other products of this nature is not necessary and is not
recommended.
NO
NO
NO
NO
NOTE
TE
TE
TE
TE
Back panel must be removed prior to disconnecting the water lines.
IMPOR
IMPOR
IMPOR
IMPOR
IMPORT
T
T
T
TANT
ANT
ANT
ANT
ANT
It is possible that dirt or scale will dislodge in the water line. Always throw away all ice
cubes made during the first 24 hours of operation when the unit is returned to service.