![Electrolux 240379005 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/electrolux/240379005/240379005_technical-manual_98514020.webp)
19
*
See NOTE at bottom of page 18.
PROBLEM
CAUSE
SOLUTION
Erratic control thermostat.
Replace control thermostat.
Faulty relay.
Replace relay or starter.
Restricted
air
flow
over
condenser.
Ensure air flow is unobstructed over
condenser.
Low voltage … fluctuation exceeds ±
10%
of 115 vac (104-127).
Call qualified electrician.
Compressor draws excessive watts.
Replace compressor.
Compressor short cycles.
Inoperative condenser fan motor.
Replace condenser fan motor.
Control thermostat is erratic or not
properly set.
Replace control thermostat or reset to
normal position.
Refrigerator exposed to high heat. (110°
or higher)
Move refrigerator to cooler location.
High room temperature.
(110° F or higher)
Advise customer not to install refrigerator
where temperature will rise above 110°F
because compressor will not maintain
proper temperatures.
Low pumping capacity compressor.
Replace compressor.
Door gaskets not sealing.
Adjust doors or replace door gaskets.
System undercharged.
Check for leaks. *
System overcharged.
Charge per listing on product serial plate. *
Interior light stays on.
Check door switch and door adjustment.
Contaminants
in
system.
Flush out system. Replace filter drier,
evacuate, and recharge. *
Capillary tube kinked or partially
restricted.
Replace heat exchanger and evaporator
assembly. *
Filter drier partially restricted.
Replace filter drier. *
Refrigerator and/or freezer compartment
overloaded … poor air circulation
Advise customer.
Restricted
air
flow
over
condenser.
Ensure air flow is unobstructed over
condenser.
Compressor runs too much.
Condenser fan motor is inoperative.
(Forced air condenser models only)
Replace condenser fan motor.
Tubing vibrates.
Adjust tubing.
Internal compressor noise.
Replace compressor.
Loose parts.
Check shelving.
Noisy.
Compressor operating at high head
pressure due to restricted air flow over
condenser.
Ensure air flow is unobstructed over
condenser.
Содержание 240379005
Страница 25: ...A 2 Pictorial Schematic Ladder Schematic Compressor Wiring ...
Страница 33: ...A 10 Electronic Dispenser Pictorial Schematic Electro Mechanical Dispenser Ladder Schematic Compressor Wiring ...
Страница 43: ...A 20 PRINTED IN USA ...
Страница 45: ...A 22 ...
Страница 47: ...A 24 ...
Страница 55: ...A 32 ...
Страница 57: ...A 34 ...
Страница 59: ...A 36 ...