Installation manual
25
Insert the measuring instrument (manometer) in the hole (A). Make sure the connection is tight to prevent air leakage.
Run the tube out on the back of the machine through the gap to the right of the drum motor.
A
fig.X00896A
• Loosen the wing nut on the damper (B).
• Measure when the machine is running with a program without heat and with an empty drum.
• By opening and closing the damper (B) the pressure in the hole (A) is either lowered or raised, thus the flow is
raised or lowered.
B
fig.W00289B