Electrolux Professional 588094 Скачать руководство пользователя страница 9

9

Danger

Meaning

caution, hot surface

danger of electrocution (shown on electrical parts with
indication of voltage)

End of use

• When the appliance is no longer to be used, make it unusable by removing the mains

power supply wiring.

A.6

Transport, handling and storage

• Due to their size, the machines can be stacked on top of each other during transport,

handling and storage by complying with that specified on the slip placed on the packing.

• Do

not

stand

under

suspended

loads

during

loading/unloading

operations.

Unauthorised personnel must not enter the work area.

• The weight of the appliance alone is not sufficient to keep it steady.
• For machine lifting and anchoring, do not use movable or weak parts such as: casing,

electrical raceways, pneumatic parts, etc.

• Do not push or pull the appliance to move it, as it may tip over.
• Machine transport, handling and storage personnel must be adequately instructed and

trained regarding the use of lifting systems and personal protection equipment suitable
for the type of operation carried out (e.g. overalls, safety shoes, gloves and helmet).

• When removing the anchoring systems, make sure the stability of the machine parts

does not depend on the anchoring and, therefore, that this operation does not cause the
load to fall off the vehicle. Before unloading the machine components, make sure all the
anchoring systems are removed.

• Machine positioning, installation and disassembly must be carried out by specialised

personnel.

A.7

Installation and assembly

• The operations described must be carried out by personnel qualified (refer to D.10

Characteristics of personnel trained for normal machine use

in compliance with the

current safety regulations, regarding the equipment used and the operating procedures.

• The plug, if present, must be accessible after positioning the appliance in the place of

installation.

• Disconnect the appliance from the power supply before carrying out any installation

procedure.

A.8

Electrical connection

Before connecting, make sure the mains voltage and frequency match those indicated on
the appliance data plate.
• Work on the electrical systems must only be carried out by specialised personnel.
• Connection to the power supply must be carried out in compliance with the regulations

and provisions in force in the country of use; arrange a suitable high-sensitivity manual-
reset differential omnipolar thermal-magnetic switch with contact gap enabling complete
disconnection in category III overvoltage conditions.

• If the power cable is damaged, it must be replaced by the Customer Care Service or in

any case by specialised personnel, in order to prevent any risk.

Содержание 588094

Страница 1: ...Chip scuttle EN Installation and operating manual Original instructions 599A2M100 82 8150 01 2021 07 ...

Страница 2: ...the machine regarding its use and maintenance The manual must be available to operators and carefully kept in the place where the machine is used so that it is always at hand for consultation in case of doubts or whenever required If after reading this manual there are still doubts regarding machine use do not hesitate to contact the Manufacturer or the au thorised Service Centre to receive prompt...

Страница 3: ...stics of personnel enabled to operate on the machine 15 D 12 Operator qualified for normal machine use 15 E TRANSPORT HANDLING AND STORAGE 16 E 1 Introduction 16 E 2 Transport 16 E 3 Handling 16 E 3 1 Procedures for handling operations 16 E 3 2 Shifting 16 E 3 3 Placing the load 16 E 4 Storage 16 F INSTALLATION DIAGRAMS 16 F 1 Dimension drawings for floor installations 16 F 2 Installation and conn...

Страница 4: ... J 5 Surfaces blackened by heat 29 J 6 Heating element support 29 J 7 Descaling 29 J 8 Heated tanks containers 29 K MAINTENANCE AND CUSTOMER SERVICE 29 K 1 Introduction 30 K 2 Maintenance intervals 30 K 2 1 Preventive Maintenance 30 K 3 Informations for maintenance 30 K 4 Repair and extraordinary maintenance 30 K 5 Periods of non use 30 L TROUBLESHOOTING 30 L 1 Introduction 30 L 2 What to do if 30...

Страница 5: ...ple in kitchens of restaurants canteens hospitals and in commercial enterprises such as bakeries butcheries etc not for continuous mass production of food Any other use is deemed improper Only specialised personnel are authorised to operate on the machine This appliance must not be used by minors and adults with limited physical sensory or mental abilities or without adequate experience and knowle...

Страница 6: ...the required PPE Failure to use the personal protection equipment by operators specialized personnel or users can involve exposure to chemical risk and cause possible damage to health depending on the model A 3 General safety The machines are provided with electric and or mechanical safety devices for protecting workers and the machine itself Never operate the machine removing modifying or tamperi...

Страница 7: ... risks remain as these could not be eliminated and must be neutralised by adopting specific measures and precautions Do not carry out any checking cleaning repair or maintenance operations on moving parts Workers must be informed of this prohibition by means of clearly visible signs To guarantee machine efficiency and correct operation periodical maintenance must be carried out according to the in...

Страница 8: ...r the packing containing it using unsuitable lifting systems or accessories or with the unbalanced load Mechanical safety characteristics hazards The appliance does not have sharp edges or protruding parts The guards for the moving and live parts are fixed to the cabinet with screws to prevent accidental access CAUTION In case of a significant anomaly e g short circuits wires coming out of the ter...

Страница 9: ... this operation does not cause the load to fall off the vehicle Before unloading the machine components make sure all the anchoring systems are removed Machine positioning installation and disassembly must be carried out by specialised personnel A 7 Installation and assembly The operations described must be carried out by personnel qualified refer to D 10 Characteristics of personnel trained for n...

Страница 10: ...es The appliance must be installed only combined with other appliances of the same range or wall mounted it s not suitable for stand alone installation Maintain a distance of at least 50 mm between the appliance and any combustible walls Do not store or use flammable materials and liquids near the appliance Check and if necessary level the appliance after positioning Incorrect levelling can cause ...

Страница 11: ...ntion is to be paid to fire prevention regulations A 13 Machine cleaning and maintenance Before carrying out any cleaning or maintenance disconnect the appliance from the power supply and carefully unplug it if present During maintenance the cable and plug if present must be kept in a visible position by the operator carrying out the work Do not touch the appliance with wet hands or feet or when b...

Страница 12: ... The Electrolux Professional warranty does not cover service trips cost to deliver and pick up the product installation training on how to use operate replacement and or supply of wear and tear parts unless resulting from defects in materials or workmanship reported within one 1 week from the failure correction of external wiring correction of unauthorized repairs as well as any damages failures a...

Страница 13: ... below The meaning of the various information given on it is listed below F Mod factory description of product Comm Mod commercial description PNC production number code Ser No serial number Type ref original production number IPX water protection class CE marking Hz power supply frequency kW max power input A current rating EL power supply voltage phase WEEE symbol C 3 Technical data Certificatio...

Страница 14: ... This appliance must not be used by minors and or adults with limited physical sensory or mental abilities or with out adequate experience and knowledge regarding its use Children shall not play with the appliance Cleaning and user maintenance shall not be made by unauthorised personnel CAUTION The machine is not suitable for installation outdoors and or in places exposed to atmospheric agents rai...

Страница 15: ...ble personal protection equipment to be worn by operators in compliance with regulations in force in the country of use The Manufacturer declines any liability for inaccuracies con tained in the manual if due to printing or translation errors Any supplements to the installation use and maintenance manual the Customer receives from the Manufacturer will form an integral part of the manual and there...

Страница 16: ...oid impacts handle the machine keeping it at minimum height from the ground For correct and safe lifting operations use the type of equipment most suitable for characteristics and capacity e g electric pallet truck or lift truck cover sharp edges check the forks and lifting procedures according to the instructions given on the packing E 3 2 Shifting The operator must have a general view of the pat...

Страница 17: ... Please note that not all models are available in the depths shown on the diagram 70 700 800 900 800 850 900 100 70 100 100 200 900 800 850 900 800 850 900 1600 1700 1800 700 800 1460 1560 1660 140 140 660 660 710 710 760 760 100 200 660 710 760 660 710 760 140 ...

Страница 18: ...ctrical connection EQ Potential equalisation x Protective panel A B C D E F G 800 710 668 585 500 100 800 850 760 718 635 550 200 700 900 810 768 685 600 EQ EQ EQ EQ EI 45 400 454 250 38 400 45 45 A A 100 200 0 D 150 E 130 40 F G 900 A B C D 45 EI EI ...

Страница 19: ...lectrical connection EQ Potential equalisation A 850 900 F 3 Accessing the appliance s internal components A 50 150 38 400 250 900 695 475 475 580 695 250 150 EI EQ EQ A 20 400 400 300 200 200 100 100 130 50 50 1 1 2 2 4 3 ...

Страница 20: ...and alone installation When installing side by side appliances are connected to a rail Different wall frames are used when setting up against a wall The ventilation engineer is responsible for assessing planning a technically correct ventilation G 2 Distances walls The appliance must not be installed on flammable walls If an appliance is set up next to or against temperature sensitive furniture or...

Страница 21: ...pliance Very slowly pull off the protective film on the stainless steel surfaces without ripping to prevent any adhesive residue Remove any adhesive residue with a non corrosive solvent Then rinse and dry the spot thoroughly G 4 3 Positioning on steel plinth or adjustable feet NOTE If installing on a steel plinth or adjustable feet always make sure these are attached to the appliance beforehand Th...

Страница 22: ...around the outer edge G 5 Wall installation G 5 1 Preparing the brackets Before you start prepare the mounting holes in the wall according to the specifications in the mounting diagram 1 Use the supplied wall anchors 1 with the threaded rods 2 The holes must have a diameter of 18 mm 0 71 and a minimum depth of 145 mm 5 71 2 Clean the hole after drilling 3 Mount the supporting profile 3 with the nu...

Страница 23: ...s taking care not to scratch the surface of the appliance Very slowly pull off the protective film on the stainless steel surfaces without ripping to prevent any adhesive residue Remove any adhesive residue with a non corrosive solvent Then rinse and dry the spot thoroughly G 6 Fastening multiple appliances together Remove lower panel A by undoing the screws Push the units together Use the adjusti...

Страница 24: ...erent versions Side panel with an overhang of 12 5 mm for individual mounting on walls Side cover without overhang to mount on covered sides Mount the faceplates onto the unit cladding when setting up The faceplates suitable for your type of installation are available as optional accessories Height Width Available for appli ance depth mm mm mm 800 850 900 1 Side panels for wall installation 400 70...

Страница 25: ...ke sure marking on part B on the rail is pointing forwards Bring the side panel D into position Put the 5 hooks of the panel F into the slots E Insert the hooks on the bottom of end rail G into the eyelets of the connecting rail Slide end rail G in the direction of the arrow to align it to the front 1 2 A B C D D E F E F 3 4 G G ...

Страница 26: ...with the supplied screws B Make sure marking on part C on the rail is pointing forwards Bring the side panel E into position Insert the hooks on the bottom of end rail F into the eyelets of the connecting rail Attach the side of side cover E using the 4 flathead screws supplied Slide end rail F in the direction of the arrow to align it to the front G 8 3 Sealing For hygiene reasons to prevent wate...

Страница 27: ...ifications electrical rating voltage amper age etc The mains supply is connected via cable installed during assembly which protrudes approximately 1 5 m out of the floor or wall The Installation and Connection Diagram F Installation DIAGRAMS shows the position of the main terminal board To get access to the connection terminal inside the appliance follow the instructions in F 3 Accessing the appli...

Страница 28: ... a high pressure cleaner or a steam cleaner this may cause it to malfunction J 2 Cleaning the appliance and accessories Before using the appliance clean all the internal parts and accessories with lukewarm water and neutral soap or products that are over 90 biodegradable in order to reduce the emission of pollutants into the environment then rinse and dry thoroughly CAUTION Do not use solvent base...

Страница 29: ...se Metal objects can spoil or damage the surface damaged surfaces become dirty more easily and are more subject to corrosion Do not let colored surfaces come into prolonged contact with acids spices salts etc Even acid fumes which build up from cleaning tiled surfaces can promote corrosion J 5 Surfaces blackened by heat Exposure to high temperatures can cause the formation of dark marks These do n...

Страница 30: ...ng modes of all functional and safety components are in accord ance with the operating instructions K 4 Repair and extraordinary maintenance NOTE Repair and extraordinary maintenance have to be carried out by specialised authorised personnel who can ask the manufacturer to supply a service manual K 5 Periods of non use If the appliance is not going to be used for some time take the following preca...

Страница 31: ... that the refrigerator components are special waste assimilable with urban waste The symbol on the product indicates that this product should not be treated as domestic waste but must be correctly disposed of in order to prevent any negative consequences for the environment and human health For further information on the recycling of this product contact the local dealer or agent the Customer Care...

Страница 32: ......

Страница 33: ......

Страница 34: ...Electrolux Professional AG Allmendstrasse 28 CH 6210 Sursee www electroluxprofessional com ...

Отзывы: