ATS-5X User Manual
Page 39 of 44
Filters
C-Message
3.4 kHz Flat
D Filter
15 kHz Flat
1010 Hz Notch
C-Message & 1010 Hz Notch
None (20 kHz Flat)
23-Tone
Transmit Level
Range:
-40 dBm to +4 dBm
Resolution:
0.01 dB
Accuracy:
±0.2 dB
Flatness:
0.1 dB
Receive Level
Range:
-90 dBm to +4 dBm
Resolution:
0.01 dB
Accuracy:
±0.2 dB
Flatness:
0.1 dB
Envelope Delay Distortion
Range:
-1800µs to +1800 µs
Resolution:
0.1 µs
Accuracy:
±5 µs
Signal to Inter-modulation Distortion
Range:
-100 dB to +100 dB
Resolution:
0.01 dB
Accuracy:
±0.2 dB
Signal to Noise
Range:
-100 dB to +100 dB
Resolution:
0.01 dB
Accuracy:
±0.2 dB
Impulse Noise
Filters
All settings valid
Threshold Level
Range:
20 dBrn to 100 dBrn
Resolution:
0.01 dB
Accuracy:
±2 dB from 20 dBrn to 40 dBrn with 15 kHz filter and no filter settings
±1 dB elsewhere
Impulse Counting
Max rate:
10 impulses per second (dead time is 100 ms)
Max Value:
> 1,000,000
Conditions:
After test is started, count impulses continuously until holding tone is detected. After holding
tone is detected, only count impulses when the holding is present.