11.3 Parameter settings
11.3 Parameter settings
The parameter settings menu is important and the first you will use when you instal the SBMS since you need to select your battery type.
Fortunately the settings are simple since all you need to do is select battery type probably type 1 “LiFePO4” since that is the most cost effective
battery for stationary energy storage do to is long cycle life compared to other type of lithium batteries and also one of the safest batteries.
Then next thing you select is the number of cells probably 8 cells or in some case 4 cells if just a 12v equivalent system is needed and the circuit
diagram on the bottom will auto update to show you how to make the connections for different number of cell configurations starting with a
minimum of 3 cells and up to max 8 cells.
The third and last setting is the battery capacity in Ah and this is needed so that SBMS can know to calculate the real SOC (State Of Charge) for
your battery pack.
In the example below you see a 4s 12V 200Ah battery using the real battery capacity will give a more accurate SOC calculation.
Then just push the Store Parameters button and a green progress bar will show up briefly (about 2 seconds) indicating that data is written to the
ISL94203 EEPROM and for this to take effect a power cycle will be needed as explained in install instructions.