1. Safety
&
Installation
The EA4709 / EA4718 requires installation by qualified personal which must
pay attention to significant safety and other regulatory standards. They should
be thoroughly familiar with the entire system before beginning installation.
Before final operation of machine be sure to test hookup with motor but
disconnected from the load. Improper wiring could cause a “motor run away”
condition, and cause serious injury or damage to the machine and personal.
Before starting installation of the EA4709 / EA4718, be sure that main power
is disconnected. After powering the drive it should not be touched by hand or
risk shock.
Take care that in case of regeneration or in brake operation the energy
recovery must be buffered by the power supply and / or a braking module.
Ensure with electronically stabilized power supplies that protection circuit isn’t
react.
Don’t switch off the power supply while the motor is turning, in this case the
drive could be destroyed by regeneration.
We recommend connecting a capacitor of 1000 µF per each ampere output
current close to power input, in parallel.
Do not repair or open drives enclosure. Result would result in personal injury
and would void all warranties.
The EA4709 / EA4718 comply with the European directive EN61800-3 (1996).
The followings points must followed:
•
A metal mounting plate with correct grounding is mandatory.
•
For installation purposes, tooth lock washers have to be used.
•
For most wiring schemes, only shielded cables are admissible, to
suppress interference with other devices. Damaged items have to be
replaced.
•
Provide for a large contact area between shields and mounting plate.
•
The motor has to be grounded in the prescribed manner.
•
The drive is an Electrostatic Sensitive Device (ESD). Electrostatic
discharge needs to be avoided.
NOTE:
Certain applications may involve special requirements. Consult Factory!