S1-3
Set val.
Methods of entering the set value
Off:
Set val.
intern The
internal
Offset
potentiometer is used.
On:
Set val.
extern External selection using a voltage between X3/1 and X3/2.
S1-4
Phase
Setting of the Hall arrangement
Off:
Phase 120°
The halls in the motor have an arrangement of 120°.
On:
Phase 60°
The halls in the motor have an arrangement of 60°.
S1-5
I peak
Pulsed Current
Off:
I peak
Off
The feature is disabled.
On:
I peak
On
The output delivers a pulsed current to the double value of
I max
.
The time is defined by the
Time
potentiometer. Setting range is
between 50 ms and 500ms.
S1-6
Enable
Enabling of the output
Off:
Enable
Off
The enable is following the signal at the input X3/3. With high the
output stage will be activated. (Refer chapter 7.1)
On:
Enable
On
With switching the switch from Off to On the output stage will be
activated.