© ElectroCraft 2022
17
CPP-A12V80A-SA-CAN Drive User Manual
4
Drive Specifications
Using the drive outside the specified absolute maximum ratings will damage the drive. Using the drive
outside normal operating specifications may not guarantee a reliable operation.
4.1
Physical Specifications
Parameter
Conditions
Typical
Units
Weight
Without mating connectors
180
g
Dimensions
Length x Width x Height
(Without mating connectors)
109.5 x 85 x 23.33
mm
4.31 x 3.43 x 0.92
Inch
4.2
Environmental Specifications
Parameter
Conditions
Min.
Typical
Max.
Units
Ambient Temperature
Operating Range
0
-
40
°C
Storage Range
-20
-
85
Ambient Humidity
Non-condensing
5
-
95
%RH
4.3
Electrical Specifications
All ratings at ambient temperatures = 0 to 40°C and PWM frequency of 20 kHz, (unless otherwise noted)
4.3.1
DC Supply Input
Parameter
Conditions
Min.
Typical
Max.
Units
Supply Voltage
Operating Range
12
-
80
VDC
Absolute maximum
10.5
-
90
Supply Current
Operating at maximum load and speed
-
12
30
A
Idle condition. No
external connections.
@ 12VDC
-
127
-
mA
@ 80VDC
-
24
-
4.3.2
+5VDC Supply Output
Parameter
Conditions
Min.
Typical
Max.
Units
Output Voltage
Operating Range
5
5.1
5.2
VDC
Output Current
Total combined current on all
connectors
-
-
250
mA
4.3.3
Motor Output
Parameter
Conditions
Min.
Typical
Max.
Units
Output Phase Current
Continuous with no additional heatsink
-12
-
12
A*
Peak Current
-30
-
30
Peak Duration maximum
(See I
2
-
2
-
s
PWM Frequency
Configured by software
20
-
80
kHz
* Values are peak of Sine