Replace the box and the lenses if they are visually damaged (for example cracks or
deep cuts during transport or handling). This is essential.
Do not look straight at the light going out of led when the scanner is switched on.
In order to prevent any risks of electrical shock you must not remove the cover. There
is no useful part for the user inside. Refer the repair to qualified personnel
.
Installation
The scanner must be attached via its screw holes to the support with help of the provided
hook. Always make sure the scanner is firmly attached to avoid vibrations and sliding during
the operation.. Always make sure the structure to which the scanner is attached is secured and
able to bear 10 times the scanner’s weight.
2. Technical specifications.
This device does not produce radio interference. This device meets European and
French requirements. Compliance has been established, and statements and
respective documents have been registered by the manufacturer. This device has been
made for indoor decorative lighting effects.
Power supply : AC 220-250V 50/60Hz
Power: 150 W
Lamp : LED 120W
Shutter/Dimmer : Blackout, 0~100 variable strobe speed and soft transition
Movement: Pan: 180° / Tilt: 70°
Beam angle: from 12° to14,5°
Functions:
- wheel color 8 white
- gobos wheel 7 fixed gobos + open
- 3 facet rotating prism
- linear focus
Weight/Dimensions :7,2 Kg / 470x190x140 mm
Operating mode
-DMX control 15 or 19 channels/Stand-Alone with built-in microphone/Stand-Alone with
automatic mode /Master/Slave Mode
3.Scanner starting up
3.1. Access to main functions :
Control panel:
”MENU“
“▼ ”
“▲”
”ENTER”
Press the “
MENU
” button to access to functions then « ▼ » or « ▲ » to browse through sub-menus,
«
ENTER
» to confirm.“
MENU
” to go back.