background image

K. Specifications

Model

BC – 1230

BC – 1240

BC - 1250

Output

Absorption Charge Voltage Selections

GEL : 14.1V ; AGM: 14.3V ; WET : 14.4V ; CALCIUM-CALCIUM : 15.5V

Absorption Charge Timer

Limited not over 4hrs

Float Charge Voltage Selections

13.2V, 13.5V, 13.8V

Battery Charger / Power Supply Selections

Yes

Yes

Yes

Maximum Output Charging Current (Continuous)

30A

40A

50A

Recommended Battery Capacity Range

100 – 300AH

120 – 400AH

150 - 500AH

Soft Start Bulk Charge

Battery Voltage to Trigger (cut-in) Soft Start
Bulk Charge Mode

<9V

Soft Start Bulk Charge Current (Current Limit)

15A

20A

25A

Ripple and Noise (Peak to Peak)

<200mV

<200mV

<200mV

Efficiency at Maximum Power (100V/230V)

>83/87%

>83/87%

>83/87%

Dual Bank Charging (Battery must be of same type)

Yes

Yes

Yes

Input

AC Voltage Range

100 – 240V 50Hz~

AC Current at Full Load (100V/230V)

5.9/2.6A

7.5/3.2A

9.4/4.0A

Protection

Overload

90-110% Rated Output Current or 50% Rated Output Current (Soft Charge)
Protection Type : Constant Current Limiting, recovers Automatically after
Fault Condition is Removed.

Short Circuit

Recovers Automatically After Fault Condition is Removed

Reverse Polarity

Car Blade Fuse

Over Temperature

Protection Type: Shut Down

OVP Output Over Voltage

Yes

Cooling

Cooling Method

Thermostatic, Variable Speed Fan

Indicators

3-Stage Battery Charger / Power Supply Mode

Yes

Charge Phase Bulk / Absorption / Float

Yes

Fault Mode

Yes

AC Power

Yes

Fuses

AC Fuses at IEC AC Power Socket

T6.3A

T8A

T10A

DC Car Blade Fuse at Front Panel

25Ax2

30Ax2

25Ax3

Accessories

Remote Temperature Sensor, Cable & Spare Fuses

Yes

Remote Control Panel

Optional

Approvals

Safety : Q061375

Yes

EMC: N2926

Yes

Others

Dimensions and Weight

220x80x200mm ; 2.4kg 220x80x261mm ; 3.0kg 220x80x261mm ; 3.2kg

Remarks

All values are based on the standard ambient temperature 25°C and pressure 0.1Mpa.

Rev. 2   08/2009
7673-2100-2522

Содержание BC-1230

Страница 1: ...er ventilation vents are unobstructed for efficient fan cooling Do not charge non rechargeable batteries Charging wrong type or under sized batteries may cause fire or explosion Do not use the charger if it has been dropped or damaged Do not remove charger casing as there is no user serviceable parts inside Do not attempt to charge a frozen battery Do not attempt to charge a damaged battery Do not...

Страница 2: ...e Selection Slide the Switch to select charging mode for GEL AGM Wet or Calcium Calcium type battery 3 Float Voltage Selection Slide the Switch to select Float Charge Voltage 13 2 13 5V 13 8V 4 Charge Status LED Display Charger ON Green 3 Stage Charger Mode Red Power Supply Mode BULK Red Bulk charging with constant maximum current ABSORPTION Orange Absorption charging with preset constant maximum ...

Страница 3: ... BC 1230 30A BC 1240 40A BC 1250 50A Battery Capacity 100 AH 300 AH 120 AH 400 AH 150 AH 500 AH C Battery Charger Installation and Connection Observe warnings and safety precautions before operating the charger Check the battery condition check the cell levels for wet type batteries and clean the battery terminals Secure the battery charger in a well ventilated area making sure the mounting surfac...

Страница 4: ...et by the user according to the type of battery used E Manual Equalization Charging for Wet and Calcium Calcium type batteries Wet lead acid and Calcium Calcium type batteries require periodic high voltage charging to balance the voltage of each cell to reverse the high concentration of electrolyte at the bottom and clear up large sulfate crystals on the plates You can use the Calcium Calcium sele...

Страница 5: ... The battery will receive the remaining charge while in Float Mode over several days It is highly recommended to switch to 3 Stage Charger Mode periodically when the external load is disconnected The external load should not exceed 50 of the maximum current draw of the charger unless the battery is fully charged If the Bulk LED is on most of the time then the load is too large G1 Power Supply Mode...

Страница 6: ...e temperature sensor and then switch on the charger to activate the temperature control function Do not plug in the Temperature Sensor into the Charger during charging I Cable Size Selection Wire Size AWG Area mm2 Maximum one way distance Metres for 2 Voltage loss 12V 30A Maximum one way distance Metres for 2 Voltage loss 12V 40A Maximum one way distance Metres for 2 Voltage loss 12V 50A 10 5 26 1...

Страница 7: ...r 20 hours of charging Absorption light remains on all the time Wrong battery type selection eg charging Gel battery with Calcium Calcium OR Wet type selection Total battery capacity is too high for dual charging Battery temperature too high Battery is defective A load is connected to the battery and the charger is not in Power Supply Mode Check the battery label and change battery type selection ...

Страница 8: ...6A 7 5 3 2A 9 4 4 0A Protection Overload 90 110 Rated Output Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is Removed Short Circuit Recovers Automatically After Fault Condition is Removed Reverse Polarity Car Blade Fuse Over Temperature Protection Type Shut Down OVP Output Over Voltage Yes Cooling Cooling Metho...

Отзывы: