background image

BC - 1230 / 1240 / 1250

3 Stage Battery Charger

User Manual

Keep this manual in a safe place for quick reference at all times.

This manual contains important safety and operation instructions for correct use of the battery charger. Read through the manual and

pay special attention to the markings and labels of the charger, battery and equipment connected to the battery.

WARNING :

Failure to observe this warning may result in injury to persons, damage to equipment and improper functioning of the Charger.

This range of Battery Chargers are designed for in-door use. Protect the charger from all liquids.

Only charge properly sized batteries.

Refer to battery manufacturer’s recommendation for battery type setting and float voltage setting.

Mount the charger to a solid base and in accordance with all local codes.

Wear protective goggles and turn your face away when connecting or disconnecting the battery.

Make sure all charger ventilation vents are unobstructed for efficient fan cooling.

Do not charge non-rechargeable batteries.

Charging wrong type or under-sized batteries may cause fire or explosion.

Do not use the charger if it has been dropped or damaged.

Do not remove charger casing as there is no user serviceable parts inside. 

Do not attempt to charge a frozen battery 

Do not attempt to charge a damaged battery.

Do not place the charger on a battery.

Do not smoke, use an open flame or create sparks near battery or charger during normal charging operation as batteries may give 
out explosive gases.

Do not charge batteries in an enclosure due to possible explosion of entrapped explosive gases.

Disconnect the mains supply before connecting or disconnecting the leads to the battery.

If the charger does not operate properly or if it has been damaged unplug the AC and DC connections.

If longer output charging cable is required, make sure the cable diameter is adequate for the cable length.

CAUTIONS:

When charging in Calcium mode disconnect the load from the battery as high charging voltage (15.5V) may cause damage to
connected equipment.

Содержание BC-1230

Страница 1: ...er ventilation vents are unobstructed for efficient fan cooling Do not charge non rechargeable batteries Charging wrong type or under sized batteries may cause fire or explosion Do not use the charger if it has been dropped or damaged Do not remove charger casing as there is no user serviceable parts inside Do not attempt to charge a frozen battery Do not attempt to charge a damaged battery Do not...

Страница 2: ...e Selection Slide the Switch to select charging mode for GEL AGM Wet or Calcium Calcium type battery 3 Float Voltage Selection Slide the Switch to select Float Charge Voltage 13 2 13 5V 13 8V 4 Charge Status LED Display Charger ON Green 3 Stage Charger Mode Red Power Supply Mode BULK Red Bulk charging with constant maximum current ABSORPTION Orange Absorption charging with preset constant maximum ...

Страница 3: ... BC 1230 30A BC 1240 40A BC 1250 50A Battery Capacity 100 AH 300 AH 120 AH 400 AH 150 AH 500 AH C Battery Charger Installation and Connection Observe warnings and safety precautions before operating the charger Check the battery condition check the cell levels for wet type batteries and clean the battery terminals Secure the battery charger in a well ventilated area making sure the mounting surfac...

Страница 4: ...et by the user according to the type of battery used E Manual Equalization Charging for Wet and Calcium Calcium type batteries Wet lead acid and Calcium Calcium type batteries require periodic high voltage charging to balance the voltage of each cell to reverse the high concentration of electrolyte at the bottom and clear up large sulfate crystals on the plates You can use the Calcium Calcium sele...

Страница 5: ... The battery will receive the remaining charge while in Float Mode over several days It is highly recommended to switch to 3 Stage Charger Mode periodically when the external load is disconnected The external load should not exceed 50 of the maximum current draw of the charger unless the battery is fully charged If the Bulk LED is on most of the time then the load is too large G1 Power Supply Mode...

Страница 6: ...e temperature sensor and then switch on the charger to activate the temperature control function Do not plug in the Temperature Sensor into the Charger during charging I Cable Size Selection Wire Size AWG Area mm2 Maximum one way distance Metres for 2 Voltage loss 12V 30A Maximum one way distance Metres for 2 Voltage loss 12V 40A Maximum one way distance Metres for 2 Voltage loss 12V 50A 10 5 26 1...

Страница 7: ...r 20 hours of charging Absorption light remains on all the time Wrong battery type selection eg charging Gel battery with Calcium Calcium OR Wet type selection Total battery capacity is too high for dual charging Battery temperature too high Battery is defective A load is connected to the battery and the charger is not in Power Supply Mode Check the battery label and change battery type selection ...

Страница 8: ...6A 7 5 3 2A 9 4 4 0A Protection Overload 90 110 Rated Output Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is Removed Short Circuit Recovers Automatically After Fault Condition is Removed Reverse Polarity Car Blade Fuse Over Temperature Protection Type Shut Down OVP Output Over Voltage Yes Cooling Cooling Metho...