background image

X-Array™ Loudspeaker Systems

immediately determine on site whether or not an
array is safe without having to make weight-distri-
bution calculations. The structural strength ratings
of the individual rigging points and the overall
X-Array™ enclosures are also presented below
so that a 

complex structural analysis can be made

for any array configuration. The reader should
consult an experienced structural engineer to
perform the complex structural analysis.

The reader is directed to section 

5. References

of this manual for a list of rigging references (for
background in general rigging practice) and me-
chanical engineering references (for background
in structural engineering analysis).

3.3 Simplified Structural-Rating Guidelines

The Guidelines:  Electro-Voice engineers have
defined a set of simplified structural-rating guide-
lines that will enable a rigger to immediately
evaluate the safety of an X-Array™ system on
site without having to make complex force-distri-
bution calculations. A combination of destructive
testing and computer modeling were used to ana-
lyze the complex forces throughout arrays.
Conservative working-load ratings were utilized to
simplify the guidelines. Therefore, array configu-
rations other than those illustrated in these simpli-
fied guidelines may be permissible – for those
applications, consult section 

3.4 Complex Struc-

tural-Rating Analysis for a detailed structural
analysis.

The simplified structural-rating guidelines are
shown in 

Figure 19

. (Note that there is a label on

the back of each flying X-Array™ loudspeaker
enclosure that includes the graphics shown in

Figure 19

.) These guidelines provide a simplified

rating for typical arrays based on the:

    1. Vertical angle of each enclosure

    2. Total weight of that enclosure plus all of the

enclosures and rigging hung below it.

    3. Relative side-to-side and front-to-back angles

of the front Xrss or Xrsl rigging straps, or
any custom front rigging straps.

    4. Relative side-to-side angles of the Xrhg grid

hinges or Xrhp pickup hinges.

Figure 19

 includes a graph of the working-load

weight-versus-angle limit rating for the X-Array™
enclosures. This working-load weight limit is appli-
cable to every enclosure in an array, and includes
the weight of that enclosure plus the total weight
of all enclosures and rigging hardware suspended
below it. The absolute enclosure angle is the ver-
tical angle of that enclosure, where 0° represents
an upright enclosure facing straight ahead

(0°-elevation angle). These working-load-versus-
angle limits take into account the complex forces
generated in the front rigging straps, the rear rig-
ging hinges, the enclosure and the (optional) pull-
up line, as a result of the complex weight
distribution throughout the array.

Also included in the simplified structural-rating
guidelines in 

Figure 19

 are side-to-side and front-

to-back angle limits for the front rigging straps on
the top enclosure. These limits apply to the Xrss
and Xrsl rigging straps, as well as any custom
wire-rope rigging straps used at the front of the
top enclosure.

In addition, the guidelines in 

Figure 19

 include a

side-to-side angle limit for the Xrhg grid hinges
and the Xrhp pickup hinges. Front-to-back limits
are not necessary for the Xrhg and Xrhp hinges.
The Xrhl linking hinges do not require any specific
angle limits, because the front-to-back angles are
taken into account by the enclosure weight-ver-
sus-angle ratings, and side-to-side angles are im-
possible to achieve with the linking hinges.

CAUTIONS for the Simplified Structural-Rating
Guidelines:
  WHEN APPLYING THE 

SIM-

PLIFIED STRUCTURAL-RATING GUIDELINES
TO ANY X-ARRAY™ LOUDSPEAKER SYSTEM
SUSPENDED OVERHEAD, THE USER MUST
OBEY THE FOLLOWING RULES:

   1.

Never exceed the working-load-versus-
angle limit for any enclosure in the array.

    2. For the top enclosure, never exceed the side-

to-side angle limit or the front-to-back angle
limit for the Xrss rigging strap, the Xrsl rigging
strap or any custom rigging strap.

    3. For the top enclosure, never exceed the

side-to-side angle limits for the Xrhg grid
hinges or the Xrhp pickup hinges.

    4. Always make sure that the hinge locking

pins on every Xrhl linking hinge, Xrhg grid
hinge and Xrhp pickup hinge are fully en-
gaged in the rigging track on the back of
every enclosure (and grid, when applicable)
before lifting overhead.

    5. Always make sure that the double-stud fit-

tings on every Xrss rigging strap, Xrsl rig-
ging strap or any custom rigging strap are
securely locked in the rigging track on the
front of every enclosure (and grid, when
applicable) before lifting overhead.

    6. Never angle more than the top two enclo-

sures up in any array column. All other en-
closures must be pointed straight ahead or
at a downward angle.

page 17

Содержание X-ARRAY

Страница 1: ...Flying Manual and Structural Ratings X ARRAY CONCERT SYSTEMS ...

Страница 2: ...es as commonly recognized in the United States and is believed to be accurate at the time of the original printing As such the information may not be directly applicable in other countries Furthermore the regulations and requirements governing rigging hardware and practices may be superseded by local regulations It is the responsibility of the user to ensure that any Electro Voice loudspeaker syst...

Страница 3: ...igging strap Between Enclosures 11 12 Using the Xrss at the Grid 11 Multiple Enclosure Angles 12 2 3 Adjusting the Horizontal Angles 12 13 2 4 Balancing and Distributing the Load 13 14 Array Load Distribution 13 14 Balancing the Grid 14 2 5 Using Pull Up Lines 14 15 Pull Up Line Techniques 14 15 CAUTIONS for Pull Up Lines 15 3 RIGGING STRENGTH RATINGS SAFETY 15 23 FACTORS AND SPECIAL CONSIDERATION...

Страница 4: ...sl NH32102 2 Xrss short wire rope rigging strap Overall Enclosure Structural Strength Rating 21 CAUTIONS for a Complex Structural Rating Analysis 21 3 5 Special Considerations 21 23 Double Stud Fittings 21 23 Flying a Single Enclosure 23 3 6 Electro Voice Structural Analysis Procedures 23 4 RIGGING INSPECTION AND PRECAUTIONS 23 24 5 REFERENCES 24 Rigging References Mechanical Engineering Reference...

Страница 5: ...180B 457 mm 18 in woofers The Xds utilizes the double wide X Array enclosure shell and does not have flying hardware Xcn Compact near field two way MB HF loud speaker system with a rotatable 60 x 40 cover age pattern The system has one ND12A 305 mm 12 in MB driver and one ND5 16 76 mm 3 in HF compression driver The Xcn utilizes the half size X Array enclosure shell and the standard X Array flying ...

Страница 6: ...osure may be hung parallel to the top enclosure or angled downward substantially relative to the top enclosure When the short Xrss straps are used between enclo sures the bottom enclosure may be hung parallel to the top enclosure or angled downward a mod erate amount relative to the top enclosure When a grid is used each array column must be balanced by adjusting the position of the grid hanger to...

Страница 7: ...16 67 in 457 2 mm 18 00 in FIGURE 2b Xn SYSTEM TYP 9 0 584 2 mm 23 00 in 353 8 mm 13 93 in 733 2 mm 28 87 in 758 8 mm 29 88 in 914 4 mm 36 00 in 441 3 mm 17 38 in 409 2 mm 16 11 in C L WEIGHT WITHOUT EXTERNAL RIGGING 87 1 kg 192 lb WITH EXTERNAL RIGGING 90 2 kg 199 lb O FIGURE 2c Xb SYSTEM TYP 9 0 584 2 mm 23 00 in 353 8 mm 13 93 in 733 2 mm 28 87 in 758 8 mm 29 88 in C L 914 4 mm 36 00 in 457 2 m...

Страница 8: ...econd as sembly ties into the right side top and bottom of the enclosure The front track extends from the top to the bottom on both sides of the enclosure eliminating the load applied to the enclosure shell These track dimensions are also similar to the widely used heavy duty aircraft L track New Haven NH34030 3HD or ATM Fly Ware ATM TRACK On both sides of the enclosure the front rigging track has...

Страница 9: ... in pairs and must be installed with the chain near the ends of the track as shown in Figure 5a Note If one grid hinge is installed in correctly with the chain at the center of the track the second grid hinge will not fit into the track cut out Key dimensions for the Xrhg grid hinges and the enclosure are presented in Figures 4a and 5a To install an Xrhg grid hinge into the track of an enclosure g...

Страница 10: ...nge bases sideways towards the end of the track until both spring loaded locking pins drop into the hinge locking pin holes in the base of the track on both enclosures Once the locking pins are fully engaged the linking hinge bases will be immovable in the track ALWAYS CHECK TO MAKE SURE THE LINKING HINGE BASES ARE SECURELY LOCKED INTO THE TRACK AND THAT THE LOCKING PINS ARE FULLY EN GAGED IN THE ...

Страница 11: ...in Figure 6a and the long Xrsl wire rope rigging strap shown in Figure 6b are identical except for their length Both consist of two New Haven NH32102 2 double stud swivel ring fittings connected together with a 4 76 mm 188 in di ameter galvanized and black plastic coated air craft wire rope See section 3 Rigging Strength Ratings Safety Factors and Special Consider ations for a detailed discussion ...

Страница 12: ...LY LOCKED INTO THE TRACK AND THAT THE SAFETY PIN IS EXTENDED OVER THE LOCKING RING BEFORE LIFTING ANY LOUDSPEAKER ENCLOSURE OVERHEAD 1 5 Grid Details ATM Fly WareTM manufactures the MEGS 4000 T grid shown in Figure 8 specifically for the X Array loudspeaker systems The grid is com pletely compatible with the X Array systems and has track on the front and rear for connecting to the top enclosure in...

Страница 13: ...hile maintaining a consistent appear ance The Xf and the Xb are acoustically sym metrical side to side and top to bottom and there fore do not need to be rotated upside down for any reason when designing arrays The Xn how ever is not acoustically symmetrical top to bottom the low frequency section is at one end while the mid bass high frequency section is at the other end which may necessitate tha...

Страница 14: ... a pair of en closures each numbered 0 through 5 These twelve positions allow a range of angles between enclosures from 0 enclosures parallel to each other to 18 down in 1 8 increments For in stance when the fittings of the Xrsl rigging straps are inserted into cutouts 0 on both the upper and lower enclosures position 0 0 as shown in Figure 9b the resulting angle between the two en closures is 0 N...

Страница 15: ... be four more holes showing when the short Xrss rigging strap is used compared to the long Xrsl strap This results in an additional 7 2 upward angle when the short Xrss is used Thus the equation for the Xrss becomes Angle 7 2 Holes Showing x 1 8 for the Xrss where negative angles indicate downward angles and positive angles indicate upward angles For example if the fittings of the short Xrss strap...

Страница 16: ... lower in the array This is best illustrated by the ex ampleshownin Figure13 An Xrss rigging strap is attached at position 1 5 between the ATM grid and the top enclosure resulting in a relative angle between the grid and enclosure of 3 6 See the sections immediately above for how to calculate the relative angles based on the rigging strap attachment locations Since the grid is level at 0 the absol...

Страница 17: ...n while maintaining a safety factor in excess of 8 1 If the total weight of a column of loudspeakers is greater than 454 kg 1 000 lb but less than the 726 kg 1 600 lb maximum the user must be concerned about the weight dis tribution front to back to ensure that a safety fac tor of 8 1 is maintained in the front rigging straps Typically the most common array configurations used in touring and perma...

Страница 18: ...sure was free hanging To force that enclosure to angle down more than gravity would allow a pull up line would need to be attached to the bottom of the enclosure at the rear Pull up lines are usually attached to the bottom back corner of the bottom enclosure in an array column Pulling back and up will force the enclo sure to angle down more until the front straps are taut Even if the enclosure wit...

Страница 19: ...the front straps the grid will become unbalanced resulting in the front of the grid tilting down and the back tilting up This imbalance could cause a sudden shift in the load that could be dangerous If multiple grids are coupled together horizontally and one grid be comes unbalanced there could be dangerous twisting forces between the unbalanced grid and adjacent balanced grids The second concern ...

Страница 20: ... of 5 1 Electro Voice insists that the working load limits of the X Array components never be exceeded resulting in a safety factor of 8 1 still being maintained for the Electro Voice components The user is cautioned that some lo cal regulations may require safety factors higher than 8 1 In that circumstance Electro Voice in sists that the user maintain the higher safety fac tor as required by the...

Страница 21: ...l weight of all enclosures and rigging hardware suspended below it The absolute enclosure angle is the ver tical angle of that enclosure where 0 represents an upright enclosure facing straight ahead 0 elevation angle These working load versus angle limits take into account the complex forces generated in the front rigging straps the rear rig ging hinges the enclosure and the optional pull up line ...

Страница 22: ...AYS BASED ON THE A VERTICAL ANGLE OF EACH ENCLOSURE B TOTAL WEIGHT OF EACH ENCLOSURE PLUS ALL ENCLOSURES AND RIGGING SUSPENDED BELOW IT C RELATIVE ANGLES OF THE FRONT RIGGING STRAPS D RELATIVE ANGLE OF THE Xrhg OR Xrhp HINGES WORKING LOAD RATINGS OTHER ARRAY CONFIGURATIONS MAY BE FOR WEIGHT DISTRIBUTION CALCULATIONS BY UTILIZING CONSERVATIVE PERMISSIBLE FOR THOSE APPLICATIONS CONSULT THE X ARRAY F...

Страница 23: ...of the enclosures and rigging suspended below If however the top enclosure in a column was angled up 10 the total allowable weight would then only be 499 kg 1 100 lb including the weight of the top enclosure plus all of the enclo sures and rigging suspended below The enclo sure working load versus angle limit shown in Figure 19 not only applies to the top enclosure in an array column but also appl...

Страница 24: ...back ratings are valid over the entire side to side range of 10 The front to back structural strength ratings for the Xrhl linking hinges shown in Figure 20b cover a full 360 rotation Although it is not possible to put the hinge into tension over 360 it is possible for the linking hinges to go into compression when pull up straps are employed Therefore the 360 rating is necessary to accommodate bo...

Страница 25: ...s CAUTIONS for a Complex Structural Rating Analysis WHEN APPLYING A COMPLEX STRUCTURAL RATING ANALYSIS TO ANY X ARRAY LOUDSPEAKER SYSTEM SUS PENDED OVERHEAD THE USER MUST OBEY THE FOLLOWING RULES 1 For the front of every enclosure in an array never exceed the working load versus angle limit for the Xrss rigging straps the Xrsl rigging straps or any custom rigging straps 2 For the back of every enc...

Страница 26: ...X Array Loudspeaker Systems page 22 ...

Страница 27: ...ts and enclosures to be analyzed for loudspeakers as sembled into arrays in both static and dynamic conditions Structural testing and computer modeling were used throughout the engineering development of all of the X Array individual rigging components and complete loudspeaker systems described in this manual Testing and modeling involving both anticipated use and anticipated misuse were per forme...

Страница 28: ...snagel L R Higgins J A MacDonald Handbook of Rigging for Construc tion and Industrial Operations McGraw Hill Book Company New York NY USA 1988 2 J O Glerum Stage Rigging Handbook Southern Illinois University Press Carbondale IL USA 1987 3 P Carter Backstage Handbook Broad way Press New York NY USA 1988 4 ATM Fly Ware Riggermeister Produc tion Rigging Guide ATM Fly Ware Carson CA USA 1995 5 Wire Ro...

Страница 29: ... together at the rear Each hinge consists of two precision machined steel rigging track fittings connected by a heavy duty steel hinge Part number 510 2998 Electro Voice 600 Cecil St Buchanan MI 49107 USA 616 695 6831 Xrsl Long Rigging Strap Two Xrsl long rigging straps are used at the front of two enclosures to adjust their relative vertical angles The Xrsl may also be used to attach the front of...

Страница 30: ...X ARRAY Flying Manual Part Number 534637 9821 600 Cecil Street Buchanan MI 49107 Phone 616 695 6831 Fax 616 695 1304 www electrovoice com Telex Communications Inc 1998 Litho in U S A ...

Отзывы: