Figure 4—Directivity

The directivity index, D

i

, and directivity

factor R

θ

(Q), of the system were measured

with a full spherical measurement system

as described for the "Polar Response."

Figure 5—Distortion

Distortion for the system was measured

on axis in the farfield in an anechoic envi-

ronment with an input signal that would

result in a sound-pressure level of 115 dB

at one meter. The Dx38 digital electronic

unit was used to provide the necessary

crossover filters, equalization and time de-

lay. A frequency spectrum typical of close-

miked rock music was employed. The

sound-pressure level was normalized for

an equivalent one-meter distance. Plots of

second and third harmonic distortion are

shown referenced to the fundamental.

Figure 6—Impedance

The impedance of each frequency band of

the system was measured in an anechoic

environment.

Figure 7—Wiring

The wiring diagram of each frequency band

of the system is shown.

DIRECTIVITY F

A

CT
OR R

q

 Q

2nd Harmonic
3rd Harmonic

LF
HF

Содержание X-Array Xw12

Страница 1: ...as well as accurate vocal coverage and maxi mized intelligibility are required from a sys tem housed in a compact low profile enclo sure Its symmetrical design will allow two monitors to be placed head to head so that the high frequency horns are coupled for high level large stage applications The Xw12 and associated controller combina tions are recommended for applications re quiring full bandwid...

Страница 2: ...And Engineers Specifications The loudspeaker speaker system shall be a two way biamped system with performance controlled by a variety of dedicated electronic control units The loudspeaker system shall have a 305 mm 12 inch direct radiating driver with an 8 ohm 63 5 mm 2 5 inch voice coil constructed of aluminum wire and shall be capable of a 300 watt shaped pink noise signal with a 6 dB crest fac...

Страница 3: ...resultingfrom improperlydesignedenclosures Electro Voice active electronics associated with the speaker systemsareguaranteedforthree 3 yearsfrom the date of original purchase Additional de tails are included in the Uniform Limited Warranty statement Electro Voice Accessories are guaranteed against malfunction due to defects in materi als or workmanship for a period of one 1 year from the date of o...

Страница 4: ...tal electronic unit was used to provide the necessary crossover filters equalization and time delay One watt of power 2 83 volts rms at 400 Hz was applied to the midband of the low frequency section The sound pressure level was normalized for an equivalent one meter distance Figure 3 Beamwidth The beamwidth of the system i e the in cluded horizontal and vertical coverage angles at the 6 dB down po...

Страница 5: ...ure level of 115 dB at one meter The Dx38 digital electronic unit was used to provide the necessary crossover filters equalization and time de lay A frequency spectrum typical of close miked rock music was employed The sound pressure level was normalized for an equivalent one meter distance Plots of second and third harmonic distortion are shown referenced to the fundamental Figure 6 Impedance The...

Страница 6: ...erage see Figure 4 14 3 9 8 5 4 Directivity Index Di 1 200 16 000 Hz Average see Figure 4 11 6 dB 2 3 dB 2 1 dB Distortion 115 dB SPL at one meter shaped spectrum see Figure 5 Second Harmonic 100 Hz 0 5 500 Hz 0 8 2 000 Hz 3 7 5 000 Hz 1 7 Third Harmonic 100 Hz 3 3 500 Hz 0 9 2 000 Hz 0 3 5 000 Hz 0 1 Transducer Complement HF DH6 driver HP type 80 x 55 horn LF DL type 12 in woofer Impedance see Fi...