REAR VIEW  

INPUT A / INPUT B

 

The inputs INPUT A & INPUT B are electronically 

 

balanced offering an input sensitivity of +6dBu (1.55V)

 

for direct connection of mixing consoles, etc.

 

Connection can be established via the XLR-type input 

 

connectors or the supplied screw-on connectors, 

 

which are connected in parallel. The pin-assignment 

 

of the XLR-type input connectors is according to the 

IEC 268 standard. In case floating inputs are needed, retrofitting optionally available input transformers 
is possible. One extension-kit NRS 90208 (Order-No. 121 641) per channel is needed

.

PARALLEL CONNECTION

Connection can be established via the XLR-type input connectors INPUT A / INPUT B or the supplied 
screw-on connectors which are connected in parallel. In addition, using the PARALLEL-connectors 
provides the possibility for connecting the input signal through to feed additional power amplifiers, 
without the need for extra splitter-cables

.

DSP OUT

The DSP output signal – i.e. the post-digital-signal-processing-unit audio signal – is present at the 
DSP OUT. The DSP output signal is simultaneously fed to the power amplifier output stage and is 
correspondingly amplified present at the power amp’s main outputs.
The DSP OUT can be utilized for feeding the digitally processed audio signal from the RCM-24 Re-
mote Control Module to additional power amplifiers (without DSP-module); e.g. for increasing the 
overall output power. With a nominal level of +6dBu and a maximum level of +21dBu (8.7V) the output 
signal is electronically balanced. Output impedance is 100

.

CONTROL PORT

 

The CONTROL PORT offers two freely programmable control inputs and 

 

control outputs as well as the reference connections for ground potential and

 

+5V. Using the PC Windows software IRIS, the control inputs can be 

 

configured and serve for instance for Power-On / Stand-by switching, preset

 

switching or parameter control.

 

 

 

 

The two control contacts IN1 / IN2 are internally set to +5V (open) via pull-up 

resistors. Activating the control inputs is possible by closing the contacts to ground potential (pin 3) 
via external switches, pushbuttons or relays. The two control outputs OUT1 / OUT2 are carried out as 
Open Collector Outputs. In non-active state (Off) they provide high ohmic resistance. In the active state 
(On) these outputs are connected to ground.
The outputs serve for signalling internal operational states. They can be used for the direct triggering 
of LEDs, indication lights or relays. The +5V reference connector provides power supply for externally 
connected appliances with amperage of maximally 100mA. The control outputs allow signal indication 
of operational states (critical temperature, exceeding or decline of defined limit values, faults, etc.) at 
central operator desks or to other systems (fire alarm system, general alert system) even without PC. 
For further detail about configuring the control ports, please refer to the documentation accompanying 
the IRIS software.

Содержание Precision P3000 RL

Страница 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG...

Страница 2: ...IONS TECHNISCHE DATEN 32 BLOCK DIAGRAM AMPLIFIER 34 BLOCK DIAGRAM RCM 24 35 DIMENSIONS ABMESSUNGEN 36 WICHTIGE SICHERHEITSHINWEISE 19 WICHTIGE SERVICEHINWEISE 19 BESCHREIBUNG 20 AUSPACKEN GARANTIE 21...

Страница 3: ...ing other than that ontained in the Operating Instructions unless you are qualified to do so Refer all ervicing to qualified service personnel 1 Security regulations as stated in the EN 60065 VDE 0860...

Страница 4: ...elevant system parameters at any time The RCM 24 module allows integration into a Remote Control Network consisting of up to 250 power amps The Windows Software IRIS Intelligent Remote Integrated Supe...

Страница 5: ...ith the warranty certificate at a safe place INSTALLATION NOTES Generally installing or mounting power amps should be carried out in a way that guarantees continuously unopposed front to rear air circ...

Страница 6: ...ation only the internal auxiliary power supply unit is activated The main power supply unit is separated from the mains The PROTECT LED lights indicating that one of the internal protection circuits a...

Страница 7: ...le e g for increasing the overall output power With a nominal level of 6dBu and a maximum level of 21dBu 8 7V the output signal is electronically balanced Output impedance is 100 CONTROL PORT The CONT...

Страница 8: ...76 191 3 0 F 48 63 C 0 F 192 207 4 0 F 64 79 D 0 F 208 223 5 0 F 80 95 E 0 F 224 239 6 0 F 96 111 F 0 A 240 250 7 0 F 112 127 F B F reserved Address 0 00 hex factory pre set ensures that the amplifier...

Страница 9: ...g appliances with RCM 24 Module installed per Easy Remote is practically pointless EASY REMOTE IN Leaving the pins of the EASY REMOTE IN socket open i e when connecting 5V the appliance power is switc...

Страница 10: ...to FAST is recommended When using the power amplifier as low frequency woofer power amp employed in active multi way systems setting the limiter switch to SLOW is recommended BRIDGED MODE Switch for c...

Страница 11: ...g a total of 250 power amps The network topology used by the CAN bus is the so called bus or line topology i e all participants are connected via a single two wire cable Twisted Pair cable shielded or...

Страница 12: ...rent order of size System with 5 amps and one UCC1 PC at the beginning of the bus Terminators at the UCC1 first unit on the bus and at amp 5 last unit on the bus System with 2 amp racks and an UCC1 PC...

Страница 13: ...nitor audio signal for monitoring the power amp inputs and outputs This monitor bus allows software controlled monitoring of the input and output signals of all power amps that are included in the rem...

Страница 14: ...300 600 m 40 m m 0 5 0 6 mm AWG20 150 300 100 kbit s at 500 m 600 1000 m 26 m m 0 75 0 8 mm AWG18 150 300 62 5 kbit s at 1000 m With longer cables and many participants on the CAN bus termination res...

Страница 15: ...al operation These values are based on operating the power amplifier with VDE noise at 1 8 of the maximum output power which approximately equates the load of the power amplifier being operated with a...

Страница 16: ...16...

Страница 17: ...BEDIENUNGSANLEITUNG...

Страница 18: ...ROL PORT 23 RS 232 INTERFACE 24 ADDRESS 24 REMOTE CAN BUS 24 EASY REMOTE 25 ENDSTUFENAUSG NGE 25 GROUND LIFT SCHALTER 25 LIMITER 26 BRIDGED MODE 26 VERKABELUNG 27 NF VERBINDUNGSKABEL 27 REMOTE CONTROL...

Страница 19: ...gt 11 Um das Ger t komplett spannungsfrei zu schalten muss der Netzstecker gezogen werden WICHTIGE SERVICEHINWEISE ACHTUNG Diese Servicehinweise sind ausschliesslich zur Verwendung durch qualifizierte...

Страница 20: ...Systemzustand und die Kontrolle ber alle relevanten Sys temparameter Das RCM 24 Modul erlaubt die Anbindung an ein Remote Control Netzwerk mit bis zu 250 Endstufen Ein komplettes PA System kann von e...

Страница 21: ...rte auch den Kaufbeleg der den Termin der bergabe festlegt auf INSTALLATIONSHINWEISE Generell sind die Endstufen so aufzustellen oder zu montieren da die Luftzufuhr an der Frontseite und die Entl ftun...

Страница 22: ...nn Im Standby Modus ist nur das interne Hilfsnetzteil aktiviert Das Leistungsnetzteil ist netzseitig getrennt Wenn die PROTECT Anzeige aufleuchtet hat eine der internen Schutzschaltungen wie bertemper...

Страница 23: ...trol Modul zu versorgen z B zur Leistungserweite rung Das Ausgangssignal ist elektronisch symmetrisch der Nennpegel betr gt 6dBu der Maximal pegel betr gt 21dBu 8 7V Die Ausgangsimpedanz betr gt 100 C...

Страница 24: ...0 F 176 191 3 0 F 48 63 C 0 F 192 207 4 0 F 64 79 D 0 F 208 223 5 0 F 80 95 E 0 F 224 239 6 0 F 96 111 F 0 A 240 250 7 0 F 112 127 F B F reserviert Die Adresse 0 00 hex Auslieferungszustand sorgt daf...

Страница 25: ...agen Eine Steuerung von Ger ten mit RCM 24 Modul per Easy Remote ist nicht sinnvoll EASY REMOTE IN Werden die Pins der EASY REMOTE IN Buchse offen gelassen bzw mit 5V beaufschlagt so schal tet das Ger...

Страница 26: ...Position FAST betrieben werden Bei Verwendung der Endstufe als Bassendstufe in aktiven Mehrwegsyste men sollte der Limiter in Position SLOW betrieben werden BRIDGED MODE Schalter zum Umschalten von No...

Страница 27: ...die IRIS Software bis zu 250 Endstufen verwalten Der CAN Bus verwendet als Netzwerktopologie die sogenannte Bus oder Linien Topologie Das heisst alle Teilnehmer sind an einer einzigen Zweidrahtleitung...

Страница 28: ...in unterschiedlichen Gr ssen ordnungen System mit 5 Verst rkern und einem UCC1 PC am Bus Anfang Abschluss Stecker am UCC1 Bus Anfang und am Verst rker 5 Bus Ende System mit 2 Racks und einem UCC1 PC...

Страница 29: ...io Monitor Signal zum Abh ren der Endstufeneing nge und ausg nge mitgef hrt Dieser Monitorbus erm glicht das softwaregesteuerte Abh ren der Eingangs oder Ausgangssignale aller im Remote Netzwerk vorha...

Страница 30: ...kbit s bei 100 m 300 600 m 40 m m 0 5 0 6 mm AWG20 150 300 100 kbit s bei 500 m 600 1000 m 26 m m 0 75 0 8 mm AWG18 150 300 62 5 kbit s bei 1000 m Bei langen Leitungen und vielen Ger ten am CAN Bus we...

Страница 31: ...tungen be stimmt werden F r normalen Betrieb k nnen die Werte der Spalte 1 8 max Ausgangsleistung 4 verwendet werden Die Endstufe wurde hier mit VDE Rauschen bei 1 8 der maximalen Ausgangsleitung betr...

Страница 32: ...Damping Factor 1kHz 300 Signal to Noise Ratio Amplifier A weighted 109dB Signal to Noise Ratio System A weighted 100dB Input Sensitivity at rated output power 8 1kHz internal selectable 6dBu factory c...

Страница 33: ...nactive OFF 5 0V 2 4V or open internal pull up Active ON 0V 0 8V 2 Control Outputs Inactive OFF High Open Collector Active ON Low 0 5V I 0 7A Input Voltage 32 0V max Switching Current 1 0A max Referen...

Страница 34: ...34 BLOCK DIAGRAM AMPLIFIER...

Страница 35: ...UT VOLTAGE CH A OUTVOLA STANDBY POWER SOURCE 5V 3 3V DC DC RJ 45 MONITOR BUS CAN RS 485 5V CAN RS 485 TRANSCEIVER MONITOR OUT B MONITOR IN A MONITOR IN B MONITOR OUT A SLAVE OUT A SLAVE OUT B CLOCK SP...

Страница 36: ...36 5 5 375 5 426 132 5 483 440 5 131 ERNST ERNST DIMENSIONS ABMESSUNGEN...

Страница 37: ...37 NOTES...

Страница 38: ...38 NOTES...

Страница 39: ...39 NOTES...

Страница 40: ...ville MN 55337 Phone 1 952 884 4051 FAX 1 952 884 0043 Germany EVI AUDIO Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 FAX 49 9421 706 265 Subject to change without prior notice P...

Отзывы: