background image

32

33

SPECIFICATIONS /  TECHNISCHE DATEN   

Load Impedance

8

4

2

Maximum Midband Output Power

THD = 1%, 1kHz

2x

850W

2x

1300W

2x

1800W

Rated Output Power 

THD < 0.2%, 20Hz ... 20kHz

2x

750W

2x

1200W

2x

1700W

Max. Single Channel Output Power

 

Dynamic-Headroom, IHF-A

950W

1700W

2000W

Maximum Bridged Output Power

THD = 1%, 1kHz

2800W

3600W

-

Maximum  RMS Voltage Swing 

THD = 1%, 1kHz

91V

Power Consumption

at 1/8 maximum output power @ 4

1850W

THD at rated output power, 

MBW = 80kHz, 1kHz

< 0.05%

IMD-SMPTE 

60Hz, 7kHz

< 0.05%

DIM30

3.15kHz, 15kHz

< 0.05%

Crosstalk Attenuation

ref. 1kHz, at rated output power

> 70dB

Frequency Response 

-0.5dB, ref. 1kHz

20Hz ... 20kHz

Damping Factor 

1kHz

>  300

Signal to Noise Ratio, Amplifier

A-weighted

109dB

Signal to Noise Ratio, System

A-weighted

100dB

Input Sensitivity

at rated output power @ 8

, 1kHz

internal selectable

+6dBu (factory configured)

0dBu

26dB constant gain

Max. Input Voltage

+21dBu (8.7V)

Input Impedance

20Hz ... 20kHz, balanced

20k

CMR

1kHz

80dB

Output Voltage

DSP OUT / Monitor

rated: +6dBu (1.55V)

max: +21dBu (8.7V)

Output Impedance

DSP OUT / Monitor

< 100

Minimum Output Load

DSP OUT / Monitor

600

Digital Signal Processing

AD & DA Conversion

24 Bit, Sigma-Delta, 128 x Oversampling, Linear Phase

Sample Rate

48kHz

Internal Wordlength

48 bit

Dynamic Range

115dB (typical)

 

   - System (amplifier) at rated conditions, both channels driven, 8

 loads, unless otherwise specified.                      

   - Depending on the ambient temperature, the unit might not operate continuously at 2

 load.

Содержание Precision P3000 RL

Страница 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG...

Страница 2: ...IONS TECHNISCHE DATEN 32 BLOCK DIAGRAM AMPLIFIER 34 BLOCK DIAGRAM RCM 24 35 DIMENSIONS ABMESSUNGEN 36 WICHTIGE SICHERHEITSHINWEISE 19 WICHTIGE SERVICEHINWEISE 19 BESCHREIBUNG 20 AUSPACKEN GARANTIE 21...

Страница 3: ...ing other than that ontained in the Operating Instructions unless you are qualified to do so Refer all ervicing to qualified service personnel 1 Security regulations as stated in the EN 60065 VDE 0860...

Страница 4: ...elevant system parameters at any time The RCM 24 module allows integration into a Remote Control Network consisting of up to 250 power amps The Windows Software IRIS Intelligent Remote Integrated Supe...

Страница 5: ...ith the warranty certificate at a safe place INSTALLATION NOTES Generally installing or mounting power amps should be carried out in a way that guarantees continuously unopposed front to rear air circ...

Страница 6: ...ation only the internal auxiliary power supply unit is activated The main power supply unit is separated from the mains The PROTECT LED lights indicating that one of the internal protection circuits a...

Страница 7: ...le e g for increasing the overall output power With a nominal level of 6dBu and a maximum level of 21dBu 8 7V the output signal is electronically balanced Output impedance is 100 CONTROL PORT The CONT...

Страница 8: ...76 191 3 0 F 48 63 C 0 F 192 207 4 0 F 64 79 D 0 F 208 223 5 0 F 80 95 E 0 F 224 239 6 0 F 96 111 F 0 A 240 250 7 0 F 112 127 F B F reserved Address 0 00 hex factory pre set ensures that the amplifier...

Страница 9: ...g appliances with RCM 24 Module installed per Easy Remote is practically pointless EASY REMOTE IN Leaving the pins of the EASY REMOTE IN socket open i e when connecting 5V the appliance power is switc...

Страница 10: ...to FAST is recommended When using the power amplifier as low frequency woofer power amp employed in active multi way systems setting the limiter switch to SLOW is recommended BRIDGED MODE Switch for c...

Страница 11: ...g a total of 250 power amps The network topology used by the CAN bus is the so called bus or line topology i e all participants are connected via a single two wire cable Twisted Pair cable shielded or...

Страница 12: ...rent order of size System with 5 amps and one UCC1 PC at the beginning of the bus Terminators at the UCC1 first unit on the bus and at amp 5 last unit on the bus System with 2 amp racks and an UCC1 PC...

Страница 13: ...nitor audio signal for monitoring the power amp inputs and outputs This monitor bus allows software controlled monitoring of the input and output signals of all power amps that are included in the rem...

Страница 14: ...300 600 m 40 m m 0 5 0 6 mm AWG20 150 300 100 kbit s at 500 m 600 1000 m 26 m m 0 75 0 8 mm AWG18 150 300 62 5 kbit s at 1000 m With longer cables and many participants on the CAN bus termination res...

Страница 15: ...al operation These values are based on operating the power amplifier with VDE noise at 1 8 of the maximum output power which approximately equates the load of the power amplifier being operated with a...

Страница 16: ...16...

Страница 17: ...BEDIENUNGSANLEITUNG...

Страница 18: ...ROL PORT 23 RS 232 INTERFACE 24 ADDRESS 24 REMOTE CAN BUS 24 EASY REMOTE 25 ENDSTUFENAUSG NGE 25 GROUND LIFT SCHALTER 25 LIMITER 26 BRIDGED MODE 26 VERKABELUNG 27 NF VERBINDUNGSKABEL 27 REMOTE CONTROL...

Страница 19: ...gt 11 Um das Ger t komplett spannungsfrei zu schalten muss der Netzstecker gezogen werden WICHTIGE SERVICEHINWEISE ACHTUNG Diese Servicehinweise sind ausschliesslich zur Verwendung durch qualifizierte...

Страница 20: ...Systemzustand und die Kontrolle ber alle relevanten Sys temparameter Das RCM 24 Modul erlaubt die Anbindung an ein Remote Control Netzwerk mit bis zu 250 Endstufen Ein komplettes PA System kann von e...

Страница 21: ...rte auch den Kaufbeleg der den Termin der bergabe festlegt auf INSTALLATIONSHINWEISE Generell sind die Endstufen so aufzustellen oder zu montieren da die Luftzufuhr an der Frontseite und die Entl ftun...

Страница 22: ...nn Im Standby Modus ist nur das interne Hilfsnetzteil aktiviert Das Leistungsnetzteil ist netzseitig getrennt Wenn die PROTECT Anzeige aufleuchtet hat eine der internen Schutzschaltungen wie bertemper...

Страница 23: ...trol Modul zu versorgen z B zur Leistungserweite rung Das Ausgangssignal ist elektronisch symmetrisch der Nennpegel betr gt 6dBu der Maximal pegel betr gt 21dBu 8 7V Die Ausgangsimpedanz betr gt 100 C...

Страница 24: ...0 F 176 191 3 0 F 48 63 C 0 F 192 207 4 0 F 64 79 D 0 F 208 223 5 0 F 80 95 E 0 F 224 239 6 0 F 96 111 F 0 A 240 250 7 0 F 112 127 F B F reserviert Die Adresse 0 00 hex Auslieferungszustand sorgt daf...

Страница 25: ...agen Eine Steuerung von Ger ten mit RCM 24 Modul per Easy Remote ist nicht sinnvoll EASY REMOTE IN Werden die Pins der EASY REMOTE IN Buchse offen gelassen bzw mit 5V beaufschlagt so schal tet das Ger...

Страница 26: ...Position FAST betrieben werden Bei Verwendung der Endstufe als Bassendstufe in aktiven Mehrwegsyste men sollte der Limiter in Position SLOW betrieben werden BRIDGED MODE Schalter zum Umschalten von No...

Страница 27: ...die IRIS Software bis zu 250 Endstufen verwalten Der CAN Bus verwendet als Netzwerktopologie die sogenannte Bus oder Linien Topologie Das heisst alle Teilnehmer sind an einer einzigen Zweidrahtleitung...

Страница 28: ...in unterschiedlichen Gr ssen ordnungen System mit 5 Verst rkern und einem UCC1 PC am Bus Anfang Abschluss Stecker am UCC1 Bus Anfang und am Verst rker 5 Bus Ende System mit 2 Racks und einem UCC1 PC...

Страница 29: ...io Monitor Signal zum Abh ren der Endstufeneing nge und ausg nge mitgef hrt Dieser Monitorbus erm glicht das softwaregesteuerte Abh ren der Eingangs oder Ausgangssignale aller im Remote Netzwerk vorha...

Страница 30: ...kbit s bei 100 m 300 600 m 40 m m 0 5 0 6 mm AWG20 150 300 100 kbit s bei 500 m 600 1000 m 26 m m 0 75 0 8 mm AWG18 150 300 62 5 kbit s bei 1000 m Bei langen Leitungen und vielen Ger ten am CAN Bus we...

Страница 31: ...tungen be stimmt werden F r normalen Betrieb k nnen die Werte der Spalte 1 8 max Ausgangsleistung 4 verwendet werden Die Endstufe wurde hier mit VDE Rauschen bei 1 8 der maximalen Ausgangsleitung betr...

Страница 32: ...Damping Factor 1kHz 300 Signal to Noise Ratio Amplifier A weighted 109dB Signal to Noise Ratio System A weighted 100dB Input Sensitivity at rated output power 8 1kHz internal selectable 6dBu factory c...

Страница 33: ...nactive OFF 5 0V 2 4V or open internal pull up Active ON 0V 0 8V 2 Control Outputs Inactive OFF High Open Collector Active ON Low 0 5V I 0 7A Input Voltage 32 0V max Switching Current 1 0A max Referen...

Страница 34: ...34 BLOCK DIAGRAM AMPLIFIER...

Страница 35: ...UT VOLTAGE CH A OUTVOLA STANDBY POWER SOURCE 5V 3 3V DC DC RJ 45 MONITOR BUS CAN RS 485 5V CAN RS 485 TRANSCEIVER MONITOR OUT B MONITOR IN A MONITOR IN B MONITOR OUT A SLAVE OUT A SLAVE OUT B CLOCK SP...

Страница 36: ...36 5 5 375 5 426 132 5 483 440 5 131 ERNST ERNST DIMENSIONS ABMESSUNGEN...

Страница 37: ...37 NOTES...

Страница 38: ...38 NOTES...

Страница 39: ...39 NOTES...

Страница 40: ...ville MN 55337 Phone 1 952 884 4051 FAX 1 952 884 0043 Germany EVI AUDIO Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 FAX 49 9421 706 265 Subject to change without prior notice P...

Отзывы: