CONTRACTOR PRECISION SERIES

Owner‘s Manual    15

Address 0 (00 hex, delivery status) disables remote communication between the RCM-810 and the bus. The module does not
appear in the system, even though it is physically connected to the CAN-bus.

2   STATUS LED

The STATUS-LED is for monitoring the communication on the CAN bus. The LED blinks rhythmically every 3
seconds, when the module’s address is set to “00“, which means that it is disconnected from the CAN bus
and software control. The LED blinks rhythmically in intervals of one second, when an address in the range of
01 to 250 has been assigned to the module and there has not yet been any activity on the CAN bus. As soon
as communication on the CAN bus is recognized, the LED lights for at least 100 ms, when the power
amplifier sends data on the CAN bus.

3   REMOTE CAN BUS Connection

The RCM-810 module provides two RJ-45 sockets for connecting to the REMOTE CAN BUS. These sockets
are connected in parallel and serve as inputs as well as for daisy-chaining the devices on the remote
network. Cabling in a rack system can be established using commercially available RJ-45 network cables.
However, CAN guidelines have to be observed for longer cable lengths. Both ends of the CAN-bus must be
terminated using 120

Ω

 terminating plugs. 

The CAN bus allows using different data rates, whereas the data rate is inversely proportional to the bus
length. For smaller network setups, data rates can be as high as 500 kbit/s. For broader networks, reducing
the data rate becomes necessary (down to the minimum data rate of 10 kbit/s).

The following table illustrates the relation between data rate and bus length or network size. The use of CAN repeaters is

strongly recommended for busses that exceed 1000 meters in length.

HIGH

LOW

Address

HIGH

LOW

Address

0

0

Stand-alone

8

0...F

128...143

0

1...F

1...15

9

0...F

144...159

1

0...F

16...31

A

0...F

160...175

2

0...F

32...47

B

0...F

176...191

3

0...F

48...63

C

0...F

192...207

4

0...F

64...79

D

0...F

208...223

5

0...F

80...95

E

0...F

224...239

6

0...F

96...111

F

0...A

240...250

7

0...F

112...127

F

B...F

reserved

Table 4.1: CAN addresses

NOTE:
The data rate of the CAN bus is preset to 10 kbit/s.

Transfer rate (in kbit/s)

Bus length (in m)

500

100

250

250

125

500

62,5

1000

20

2500

10

5000

Table 4.2: Transfer rate and bus length

Содержание CPS2.12

Страница 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG...

Страница 2: ......

Страница 3: ...13 Fan Cooling 13 Options 14 RCM 810 14 INHALT Einf hrung 19 Willkommen 19 Auspacken und Inspektion 19 Lieferumfang und Garantie 19 Eigenschaften Beschreibung 19 Verantwortung des Betreibers 19 Instal...

Страница 4: ...0065 VDE 0860 IEC 65 and the CSA E65 94 have to be obeyed when servicing the appliance 2 Use of a mains separator transformer is mandatory during maintenance while the appliance is opened needs to be...

Страница 5: ...inal invoice that states the purchase delivery date together with the warranty certificate at a safe place 1 4 Features and Description Electro Voice CONTRACTOR PRECISION SERIES Series amplifiers offe...

Страница 6: ...his equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by...

Страница 7: ...Off Indicator POWER 5 Standby Indicator STANDBY 6 Remote Amplifier Indicator IRIS Net 7 Mains Switch 1 Mains Input 2 Ground Lift Switch CIRCUIT TO CHASSIS SWITCH 3 POWER REMOTE connector 4 Power On De...

Страница 8: ...otherwise might be heard through the loudspeakers PROTECT LED light and fans are at high speed during this delay This indicates all protections are working fine 2 4 Mounting CPS amplifiers have been...

Страница 9: ...ormers Set the switch to the 50Hz position for activating the High Pass Filter Set the switch to the OFF position if no attenuation of low frequency audio signals is required 2 8 Power on delay The ON...

Страница 10: ...ecting speakers in DUAL or PARALLEL mode The correct connection is also indicated at the amplifiers rear panel BRIDGED In BRIDGED mode both amp channels work in push pull operation to provide doubled...

Страница 11: ...ring signals are to be expected in the vicinity of the power amplifier In this case bridging the screen shielding and the pin of the inverting input inside of the connector is mandatory Otherwise a 6...

Страница 12: ...vertical LED chains on the power amp s front panel that individually indicate the actual levels of each channel at 30dB 10dB and 3dB below full modulation The LIMIT LED lights as soon as the integrate...

Страница 13: ...OTE is not recommended Leaving the pins of POWER REMOTE socket open the appliance power is switched on When connecting the pins the applicance enters standby mode 3 4 Fan Cooling The power amplifier h...

Страница 14: ...g an automatic reaction when specific thresholds are being exceeded or fallen below is also possible All parameters like power on off muting etc can be controlled in real time and stored in the amplif...

Страница 15: ...the remote network Cabling in a rack system can be established using commercially available RJ 45 network cables However CAN guidelines have to be observed for longer cable lengths Both ends of the C...

Страница 16: ...lays to connect them to ground potential pin 3 The two control outputs OUT1 and OUT2 are open collector outputs which are highly resistive in the non active state off In active state on the outputs ar...

Страница 17: ...CONTRACTOR PRECISION SERIES Owner s Manual 17...

Страница 18: ...rwendung durch qualifiziertes Servicepersonal Um die Gefahr eines elektrischen Schlages zu vermeiden f hren Sie keine Wartungsarbeiten durch die nicht in der Bedienungsanleitung beschrieben sind au er...

Страница 19: ...en sind damit der ideale Antrieb f r typische Anwendungen in der Festinstallation wie z B mit Lautsprechern der Serien EVI FRi FRX oder Variplex Die Endstufen der CPS Serie sind gegen berhitzung berla...

Страница 20: ...eige Betrieb POWER 5 Anzeige Standby STANDBY 6 Anzeige Remote Amplifier IRIS Net 7 Netzschalter 1 Netzeingang 2 Schalter Groundlift CIRCUIT TO CHASSIS SWITCH 3 POWER REMOTE Buchse POWER REMOTE 4 Einsc...

Страница 21: ...die Ausgangsrelais um ca 2 Sekunden verz gert zugeschaltet Hierdurch werden etwaige Einschaltger usche effektiv unterdr ckt die ansonsten in den Lautsprechern h rbar w ren W hrend dieser Verz gerung...

Страница 22: ...terstellung 50Hz ist der Hochpassfilter aktiviert in Schalterstellung OFF ist der Hochpassfilter nicht aktiviert 2 8 Einschaltverz gerung ber den Einschaltverz gerungs Wahlschalter ON DELAY auf der R...

Страница 23: ...rrekte Anschlussweise f r diese Betriebsart ist zus tzlich auf der Endstufe selbst abgebildet BRIDGED In der Betriebsart BRIDGED werden die beiden Endstufenkan le im Gegentakt betrieben um eine Verdop...

Страница 24: ...rwarten sind kann auch ein unsymmetrisches Signal angeschlossen werden In diesem Fall ist es zwingend erforderlich eine Br cke im Eingangsstecker zwischen Schirm und dem invertierenden Eingang zu scha...

Страница 25: ...nnt f r die beiden Kan le mit den jeweiligen LEDs 30dB 10dB und 3dB unter Vollaussteuerung Die LIMIT LED leuchtet auf sobald einer der eingebauten dynamischen Audio Limiter anspricht und die Endstufe...

Страница 26: ...rden die Pins der POWER REMOTE Buchse offen gelassen so schaltet das Ger t ein Bei einer Verbindung der Pins schaltet das Ger t in den Standby Modus 3 4 L fter Die Endstufen der CPS Serie besitzen zwe...

Страница 27: ...danz usw werden in IRIS Net zentral erfasst und dargestellt Dadurch kann schon vor dem Auftreten von kritischen Betriebzust nden reagiert und gezielt eingegriffen werden Eine automatische Reaktion bei...

Страница 28: ...Modul besitzt zwei RJ 45 Buchsen f r den REMOTE CAN BUS Die Buchsen sind parallel geschaltet und dienen als Eingang und zum Weiterschleifen des Remote Netzwerkes Zur Verkabelung innerhalb des Racks k...

Страница 29: ...Open Collector Outputs die im nichtaktiven Zustand Off hochohmig sind Im aktiven Zustand On sind die Ausg nge gegen Masse geschlossen Die Steuerausg nge werden ber IRIS Net konfiguriert und dienen zur...

Страница 30: ...kHz Voltage Gain ref 1 kHz 32 0 dB Input Sensitivity rated power 8 1 kHz 2 2 dBu 1 0 Vrms 3 1 dBu 1 11 Vrms 5 1 dBu 1 39 Vrms 6 6 dBu 1 66 Vrms THD at rated output power MBW 80 kHz 1 kHz 0 03 IMD SMP...

Страница 31: ...0 Normal Mode 10 dB 4 3 230 3 0 450 80 370 1262 Rated Output Power 0 dB 4 3 230 7 6 1380 800 580 1979 Alert Alarm Mode 3 dB 4 3 230 5 7 1000 400 600 2047 Max Output Power 2 3 230 12 1 2250 1300 950 32...

Страница 32: ...3 2 460 160 300 1024 Rated Output Power 0 dB 4 3 230 14 4 2640 1600 1040 3549 Alert Alarm Mode 3 dB 4 3 230 10 2 1770 800 970 3310 Max Output Power 2 3 230 21 6 4090 2800 1290 4402 1 8 Max Output Powe...

Страница 33: ...CONTRACTOR PRECISION SERIES Owner s Manual Bedienungsanleitung 33 5 2 Block Diagram Blockschaltbild...

Страница 34: ...CONTRACTOR PRECISION SERIES 34 Owner s Manual Bedienungsanleitung 5 3 Dimensions Abmessungen...

Страница 35: ......

Страница 36: ...31 Canada Phone 1 866 505 5551 Fax 1 866 336 8467 Latin America Phone 1 952 887 5532 Fax 1 952 736 4212 Bosch Sicherheitssysteme GmbH Robert Koch Stra e 100 D 85521 Ottobrunn Germany Contact Visitor A...

Отзывы: