6
5.7. DC-VOLTAGE-PROTECTION TEST
•
HI/LO-Cut off, Limiter set to SLOW
testing has to be performed for both channels of the power amplifier individually:
-
drive the power amplifier with a test signal (f = 7 Hz) and without load resistor connected.
-
at an input voltage of approx. 4 Vpeak the protection circuit reacts and tries continuously to re-start!
The protect-LED blinks with the same frequency.
-
Repeat the test with f = 14 Hz; the power amplifier should not switch off.
5.8. HF-PROTECTION TEST
Caution:
it is mandatory to drive the power amplifier without load resistors connected. Set the fan service
switch to ON and the HI/LO-Cut to OFF. Switch off the limiter via S102 or by disconnecting the bridge
between CNASERV 1 and CNASERV 3. Drive the power amplifier with a with 7 Vrms and a sine burst of
f =
60 kHz
(100 ms ON, 900 ms OFF), applied to each channel at a time. The protection circuit has to react. The
power amplifier tries to re-start continuously while the PROTECT LED blinks with the same frequency.
Repeat the test with
f = 30 kHz
and the limiter set to ON; the power amplifier should not switch off.
6.
Level CHANNEL A&B:
•
set the level control to its fully clockwise position.
•
set the INPUT ROUTING switch to: DUAL / STEREO.
•
HI-LOW-CUT switch is ON (as factory pre-set!).
•
BRIDGED MODE: NORMAL
•
LIMITER: SLOW (as factory pre-set!)
•
THD < 0.1 %
6.1. NOMINAL LEVEL
Input
U(E)
Measuring point
U(A)
Load resistor
Jumper on
86208/86212
CH. A/B
0 dBu
SPEAKER A/B
56.6 V
4 Ohm
select J11,J21
CH. A/B
+ 6 dBu
SPEAKER A/B
56.6 V
4 Ohm
select J12,J22
CH. A/B
+ 13 dBu
SPEAKER A/B
56.6 V
4 Ohm
select J13,J23
CH. A/B
+1 dBu
SPEAKER A/B
63.2 V
8 Ohm
select J11,J21
CH. A/B
-2 dBu
SPEAKER A/B
44.7 V
2 Ohm
select J11,J21
6.2. MAXIMUM INPUT LEVEL:
U(E) = +21 dBu (8.7 Vrms)
7.
INPUT-ROUTING switch
DUAL / STEREO (as factory pre-set!)
-
channel A and B have to be driven separately.
PARALLEL / MONO
-
channel A and B are paralleled at the input. Both channels can be driven using a common signal
source.
8.
Level BRIDGED MODE
•
set the level control all the way to its fully clockwise position.
•
HI-LOW-CUT switch is ON (as factory pre-set!).
•
BRIDGED MODE: BRIDGED
•
LIMITER: SLOW (as factory pre-set!)
•
THD < 0.1 %
BRIDGED:
Double the output voltage is presented at the BRIDGED OUT connector. It is mandatory to use the
CHANNEL A input connector. The CHANNEL B input connector is without function.
Input
U(E)
Measuring point
U(A)
Load resistor
Remarks
CH. A
0 dBu
BRIDGED OUT
89.4 V
4 ohms
select J11,J21
CH. A
0 dBu
BRIDGED OUT
113.2 V
8 ohms
select J11,J21
9.
GROUND LIFT switch
Test the functioning of the switch using an ohm-meter:
The circuit ground (at the input or the output connector) is measured versus the common ground of the
enclosure (contact at the ground terminal, located on the rear panel - or common ground of the mains cord).
Содержание CPS 3
Страница 1: ...SERVICE MANUAL CPS 4 CONTRACTOR PRECISION SERIES...
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 54: ......