5
5.2.2. LIMITER FAST/SLOW-Test
•
tests have to be performed for both channels of the power amplifier individually: testing has to be
performed without load resistors connected.
1.)
Drive the power amplifier with a burst signal (f = 1 kHz, 1-10 cycles, rate:
≈
0.5 sec.) and U(E) =
+10 dB above the nominal input voltage.
2.)
When monitoring the output signal via oscilloscope, continuously press the FAST/SLOW-switch.
•
SLOW: after 2-3 signal periods, the limiter controlled the major distortion down to a minor residual
distortion (THD = 1 % … 2 %).
•
FAST: already after 1-2 signal periods, the limiter controlled the major distortion down to a minor
residual distortion (THD = 1 % … 2 %).
When shipped, the appliance is set to SLOW!
5.3. POWER-ON DELAY:
Approximately 2 seconds after switching the power on, the relays E1 and E3 which are located on the printed
board assembly 86207/86211 and the relay E1 on the printed board assembly 84157 (channel A/B) pull
simultaneously.
5.4. FAN CONTROL:
Upon powering-on the power amplifier, the fans will run for approximately 2 seconds and stop when the power
amplifier has re-gained its "normal" temperature. In idling condition (power-on, no signal present) the fans are
switched between the SLOW and OFF mode, depending on the heat sink's temperature. When the switch S001
on the printed board assembly 86207/86211 is closed, the fans will run with FAST speed. When shipped, the
S001 switch is set to "OPEN"!
Connecting a variable resistor (approx. 50 k
Ω
) between CNBSERV 5 and CNBSERV 6 allows for testing the
functioning of the fans. During operation, CNASERV 6 can be utilized to monitor the temperature of the heat
sink.
FAN SPEED
U(DC)
CNASERV 6
U(DC)
CNBSERV 4
Remarks
Stufe 0
< 6.5 V
0 V
Fans are not running
Stufe 1
6.5 V ... 7.5 V
12.5 V
Stufe 2
7.5 V ... 9 V
19.5 V
Stufe 3
9 V ... 12.5 V
27.5 V
Protect
> 12.5 V
27.5 V
Power amplifier is switched off
5.5. SOAR-PROTECTION TEST:
Channels separately driven up to 69.3 V on 4
Ω
. Parallel connect a 0.1
Ω
resistor. The protection circuit reacts
and tries continuously to re-start! The protect-LED blinks in the same rhythm.
5.6. SHORT-CIRCUIT CURRENT-LIMITING TEST
testing has to be performed for both channels of the power amplifier individually:
- drive the channel with a burst signal (f = 1 kHz, 1-10 cycles, rate
≈
1 sec.) without load, with U(A) = 89 V
- connect a load resistor of 1
Ω
.
- the short-circuit current-limiter limits the output voltage at the load resistor symmetrically (monitor via
oscilloscope!) to a peak voltage value of 45 V ( approx. 45 A).
5.7. DC-VOLTAGE-PROTECTION TEST
•
HI/LO-Cut off, Limiter set to SLOW
testing has to be performed for both channels of the power amplifier individually:
-
drive the power amplifier with a test signal (f = 7 Hz) and without load resistor connected.
-
at an input voltage of approx. 3 Vpeak the protection circuit reacts and tries continuously to re-start!
The protect-LED blinks with the same frequency.
-
Repeat the test with f = 14 Hz; the power amplifier should not switch off.
5.8. HF-PROTECTION TEST
Caution:
it is mandatory to drive the power amplifier without load resistors connected. Set the fan service
switch to ON and the HI/LO-Cut to OFF. Switch off the limiter via S102 or by disconnecting the bridge between
CNASERV 1 and CNASERV 3. Drive the power amplifier with a with 7 Vrms and a sine burst of
f = 60 kHz
(100 ms ON, 900 ms OFF), applied to each channel at a time. The protection circuit has to react. The power
amplifier tries to re-start continuously while the PROTECT LED blinks with the same frequency.
Repeat the test with
f = 30 kHz
and the limiter set to ON; the power amplifier should not switch off.
Содержание CPS 3
Страница 1: ...SERVICE MANUAL CPS 4 CONTRACTOR PRECISION SERIES...
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 54: ......