2.4
Electrical Installation
2.4.1
Connecting to a 6.6Amp AGL circuit
The 6.6A Waggy LED high intensity runway guard light is supplied with a 300mm flying lead and a
factory fitted L-823 connector.
The connector can be plugged directly into the secondary circuit of a 100W L-830 ground isolation
transformer as shown in figure below.
CAUTION
:
The Waggy LED runway guard light can be supplied in either a 230/240V AC powered
configuration, OR a 6.6Amp AGL configuration. Please ensure that you connect the equipment to the
correct supply.
L823 Soket (By Others)
L823 Lead with Plug
2.4.2
Connecting to a 230/240V AC supply
The 230/240V Waggy LED high intensity runway guard light is supplied with a 3-core (3 x 1.0mm2)
1m flying lead. The overall diameter of the cable is nominally 7.5mm.
Connect the free ends of the cable to the proper voltage source.