Electro Industries Mini-Boiler EMB-S-1 Скачать руководство пользователя страница 20

 

 

Page 2 of 2 

XX017 

CONDITIONS AND LIMITATIONS: 

1.  This warranty is limited to residential, single family dwelling installations only.  Any commercial or multi-unit 

dwelling installations fall under the Electro Industries Commercial Limited Product Warranty. 

2.  Electro Industries, Inc. shall not be liable for performance related issues resulting from improper installation, 

improper sizing, improper duct or distribution system, or any other installation deficiencies. 

3.  If at the time of a request for service the original owner cannot provide an original sales receipt or a warranty 

card registration then the warranty period for the product will have deemed to begin the date the product is 
shipped from the factory and 

NOT

 the date of original purchase. 

4.  The product must have been sold and installed by a licensed electrician, plumbing, or heating contractor. 

5.  The application and installation of the product must be in compliance with Electro Industries, Inc. specifications, 

as stated in the installation and instruction manual, and all state, provincial and federal codes and statutes.  If 
not, the warranty will be null and void. 

6.  The purchaser shall have maintained the product in accordance with the manual that accompanies the unit.  

Annually, a qualified and licensed contractor must inspect the product to assure it is in proper working condition. 

7.  All related heating components must be maintained in good operating condition. 

8.  All lines must be checked to confirm that all condensation drains properly from the unit. 

9.  Replacement of a product or product part under this limited warranty does not extend the warranty term or 

period. 

10.  Replacement product parts are warranted to be free from defects in material and workmanship for ninety (90) 

days from the date of installation.  All exclusions, conditions, and limitations expressed in this warranty apply. 

11.  Before warranty claims will be honored, Electro Industries, Inc. shall have the opportunity to directly, or through 

its authorized representative, examine and inspect the alleged defective product or product parts. Remedies 
under this warranty are limited to repairing or replacing alleged defective product or product parts.  The decision 
whether to repair or, in the alternative, replace products or product parts shall be made by Electro Industries, Inc. 
or its authorized representative. 

THIS WARRANTY DOES NOT COVER: 

1.  Costs for labor for diagnosis, removal or reinstallation of an alleged defective product or product part, 

transportation to Electro Industries, Inc., and any other materials necessary to perform the exchange, except as 
stated in this warranty.  Replacement material will be invoiced to the distributor in the usual manner and will be 
subject to adjustment upon verification of defect. 

2.  Any product or product part that has been damaged as a result of being improperly serviced or operated, 

including, but not limited to, the following: operated during construction phase, with insufficient water or air flow; 
allowed to freeze; subjected to flood conditions; subjected to improper voltages or power supplies; operated with 
air flow or water conditions and/or fuels or additives which cause unusual deposits or corrosion in or on the 
product; chemical or galvanic erosion; improper maintenance or subject to any other abuse or negligence. 

3.  Any product or product part that has been damaged as a result of natural disasters, including, but not limited to, 

lightning, fire, earthquake, hurricanes, tornadoes or floods. 

4.  Any product or product part that has been damaged as a result of shipment or handling by the freight carrier.  It 

is the receiver’s responsibility to claim and process freight damage with the carrier. 

5.  Any product or product part that has been defaced, abused or suffered unusual wear and tear as determined by 

Electro Industries, Inc. or its authorized representative. 

6.  Workmanship of any installer of the product or product part.  This warranty does not assume any liability of any 

nature for unsatisfactory performance caused by improper installation. 

7.  Transportation charges for any replacement product, product part or component, service calls, normal 

maintenance; replacement of fuses, filters, refrigerant, etc. 

 

 

THESE WARRANTIES DO NOT EXTEND TO ANYONE EXCEPT THE ORIGINAL PURCHASER AT RETAIL AND ONLY WHEN THE PRODUCT IS 
IN THE ORIGINAL INSTALLATION SITE.  THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE. 

ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE 
HEREBY DISCLAIMED WITH RESPECT TO ALL PURCHASERS OR OWNERS.  ELECTRO INDUSTRIES, INC. IS NOT BOUND BY PROMISES 
MADE BY OTHERS BEYOND THE TERMS OF THESE WARRANTIES.  FAILURE TO RETURN THE WARRANTY CARD SHALL HAVE NO 
EFFECT ON THE DISCLAIMER OF THESE IMPLIED WARRANTIES. 

ALL EXPRESS WARRANTIES SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS LIMITED WARRANTIES SET FORTH HEREIN AND 
EXCLUDE ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES RESULTING FROM THE BREACH THEREOF.  SOME STATES 
OR PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE 
LIMITATIONS OR EXCLUSIONS MAY NOT APPLY.  PRODUCTS OR PARTS OF OTHER MANUFACTURERS ATTACHED ARE SPECIFICALLY 
EXCLUDED FROM THE WARRANTY. 

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY HAVE OTHER RIGHTS WHICH VARY UNDER THE LAWS OF EACH 
STATE. IF ANY PROVISION OF THIS WARRANTY IS PROHIBITED OR INVALID UNDER APPLICABLE STATE OR PROVINCIAL LAW, THAT 
PROVISION SHALL BE INEFFECTIVE TO THE EXTENT OF THE PROHIBITION OR INVALIDITY WITHOUT INVALIDATING THE REMAINDER OF 
THE AFFECTED PROVISION OR THE OTHER PROVISIONS OF THIS WARRANTY.

 

Содержание Mini-Boiler EMB-S-1

Страница 1: ...g systems This model includes factory installed temperature sensing staging Comment If this application is for traditional hydronic heating requiring temperatures greater than 160 F and capacities larger than shown above contact factory for other Electro Boiler product series In this approximate sizing the EB M model series is fully modulating and designed for temperatures up to 180 F The EB M and...

Страница 2: ...g Staging Control 1 Room Thermostat Placement 1 Built In Temperature Control 2 Water Flow Calculation 2 Installation Requirements 2 Electric Supply 3 Clearances 3 Mechanical Installation 4 Electrical Hookup 5 Water Fill Procedure 6 Operational Tips 8 Troubleshooting Helps 9 Drawings BX305 BH310 UAW411 BL001 XX017 ...

Страница 3: ...MB S 5 3 07 11 60 06 018 1 53 5 78 02 006 EMB S 7 4 78 18 06 12 036 2 39 9 03 06 01 EMB S 9 6 14 23 20 23 07 3 07 11 60 10 03 Note Head Loss based on 110 F return temperature TEMPERATURE SENSING STAGING CONTROL This model series is factory equipped with a digital supply water sensor and a staging controller The controller regulates the elements to maintain a preset maximum or preset operating temp...

Страница 4: ...at least 15 minutes GPM Volts x Amps x 3 4 Example 240 volts x 36 amps x 3 4 29376 5 8 gpm 500 x Temp rise 500 x 10 degree rise 5000 INFORMATION WATER FLOW CALCULATIONS METRIC L min Volts x Amps x 3 587 Example 240 volts x 36 amps x 3 587 30991 68 20 57 L min 251 04 x Temp rise C 251 04 x 6 C rise 1506 24 INSTALLATION REQUIREMENTS 1 All installation work must be performed by trained qualified cont...

Страница 5: ...actices for handling electrical sheet metal and material handling processes Use them ELECTRIC SUPPLY Model Volts Phase Watts Btu h Amps CB Element Stg 1 Stg 2 EMB S 1 120 1 60 Hz 1 100 3 753 9 2 1 EMB S 2 120 1 60 Hz 2 500 8 530 20 8 1 EMB S 4 120 1 60 Hz 5 000 17 060 41 7 1 1 EMB S 5 240 208 1 60 Hz 4 500 3 500 15 354 11 942 18 8 16 8 30A 1 EMB S 7 240 208 1 60 Hz 7 000 5 300 23 885 17 913 29 2 2...

Страница 6: ... required This can be an air diaphragm tank as provided in the plumbing kit or a basic empty tank where air is compressed at the tank top Temperature Pressure Gauge Recommended to observe the operation of the system Actually a temperature gauge at the inlet and outlet is desirable Pressure Safety Valve This is required at the hot outlet and is furnished as a loose component with the boiler unit it...

Страница 7: ...NNECTION TO THE CIRCUIT BREAKER TERMINALS AND INSIDE THIS PRODUCT S CABINET WARNING TO AVOID THE RISK OF ELECTRIC SHOCK OR DEATH WIRING TO THE UNIT MUST BE PROPERLY GROUNDED FAILURE TO PROPERLY GROUND THE UNIT CAN RESULT IN A HAZARD LEADING TO PERSONAL INJURY OR DEATH NOTE This model series is designed and equipped for 240 volt residential single phase If this unit is used on 208 volt energy capac...

Страница 8: ...S 1 Unless the source water is unusually poor and or rust elements additives are not required It is recommended the water source as shown on drawing BX305 comes through the household water softener 2 Impurities within a closed loop hydronic boiler are considerably less damaging than the typical domestic water heater In a closed loop electric boiler the water impurities boil out and the system esse...

Страница 9: ...he metal pipe and listen for air bubbles If the water flow is consistent and quiet the system is probably purged and water filled 9 Close the drain valve Open the inlet gate valve 10 The cold system pressure at the gauge should be approximately 10 to 14 PSI 11 Close water supply valve and disconnect water supply 12 Optional The circulating pump can be energized during this fill operation by having...

Страница 10: ...W input or interrupted by the load control device even though there is a W input This diagram illustrates this pin jumper arrangement This unit is factory setup in the W position meaning the pump will always run as a direct function of R to W operating thermostat By simply moving this black 2 position jumper to the L the pump will be turned off during load control interrupt 8 At outlet temperature...

Страница 11: ...same as a blown fuse no front panel boiler power green LED To reset this device simple press the red button Comment The hi limit auto reset red LED is only operational during an active heat call lower red LED on WARMFLO TEMPERATURE BYPASS TROUBLESHOOTING OR TESTING Adding a jumper between W screw terminal and tab marked E bypasses the temperature sensing and WarmFlo control In other words with the...

Страница 12: ...EMB S H 12 04 18 1 of 2 BX305 ...

Страница 13: ...EMB S H 12 04 18 2 of 2 BX305 ...

Страница 14: ...EMB S EMB H 03 19 19 1 of 2 BH310 G ...

Страница 15: ...EMB S EMB H 03 19 19 2 of 2 BH310 G ...

Страница 16: ...DECAL TITLEBLOCK ...

Страница 17: ...itional 4 enclosure and 40VA transformer Pumps EB ZEA8 with enclosure and 40VA transformer for 8 zone pumps Zone Valves EB ZTS 1 install within boiler cabinet encl option EB ZTS 2 add additional 4 enclosure and 40VA transformer EB ZES8 with enclosure no transformer for 8 zone valves ZONE CONTROLLER SWITCHING RELAY EE 5051 MULTI BOILER EB C STG5 This DPDT 24 volt switching relay provides a convenie...

Страница 18: ...erature pressure gauge pressure relief safety valve and when applicable the WarmFloTM electronic control sensors These kits provide the additional components for easy installation 5585 Mini Boiler 10 kW TS Series 5586 TS Series Standard 5578 3 4 Pipe 5582 1 Pipe 5579 1 1 4 Pipe 120V 1 25 HP maintenance free wet rotor circulator Pump curve example 5 GPM 19 L 11 ft of head 32 9 kPa 120V 1 6 HP maint...

Страница 19: ...acement Labor Allowance Schedule for a period of ninety 90 days from the date of original purchase to the original owner at the original installation site The Repair Replacement Labor Allowance is designed to reduce the cost of repairs This Repair Replacement Labor Allowance may not cover the entire labor fee charged by your dealer contractor TWENTY YEAR 20 LIMITED WARRANTY ON BOILER ELEMENTS AND ...

Страница 20: ...ubject to adjustment upon verification of defect 2 Any product or product part that has been damaged as a result of being improperly serviced or operated including but not limited to the following operated during construction phase with insufficient water or air flow allowed to freeze subjected to flood conditions subjected to improper voltages or power supplies operated with air flow or water con...

Отзывы: