13 Troubleshooting Charts
— continued
PROBLEM
PROBABLY CAUSE
REMEDY
Product
dispenses
slowly out of
dispensing
head.
1. Product too cold.
1. See Troubleshooting Table -
Dispensed product too hard.
2. Wrong rotation on beater.
2.
Have an electrician correct rotation to
clockwise as viewed from the front of
the freezer.
Dispensed
product too
hard.
1.
Torque control erratic or set too firm
1. Contact your Electro Freeze
distributor for service.
2. Low suction pressure, refrigeration
system.
2. Contact your Electro Freeze
distributor for service.
Freezer runs
continually and
product gets
too cold.
1. Plunger switch rod engaged.
1. Close plunger completely.
2. Starter or relay contact points stuck.
2. Contact your Electro Freeze
distributor for service.
3. Torque control not set properly or faulty.
3. Contact your Electro Freeze
distributor for service.
4. Suction pressure too low.
4. Contact your Electro Freeze
distributor for service.
Compressor
and beater
motor do not
operate when
dispensing.
1. Plunger switch(es) defective or out of
adjustment.
1. Contact your Electro Freeze
Distributor for service.
2. Time delay defective.
2. Contact your Electro Freeze
Distributor for service.
Compressor
motor does not
operate when
dispensing.
1. Plunger switch defective or out of adjust-
ment.
1. Contact your Electro Freeze
distributor for service.
2. Time delay defective.
2. Contact your Electro Freeze
distributor for service.
3. Defective torque control.
3. Contact your Electro Freeze
distributor for service.
Содержание CS700-FG
Страница 2: ......
Страница 7: ...ELECTRO FREEZE Shake Model CS700 FG Safety Decal Locations v 1 P N HC165126 2 P N HC165025 ...
Страница 10: ......
Страница 16: ...ELECTRO FREEZE Shake Model CS700 FG 185231 17 6 4 Part Names and Functions Figure 4 1 Head Assembly ...
Страница 46: ......
Страница 48: ......
Страница 54: ...ELECTRO FREEZE Shake Model CS700 FG 185231 17 6 Figure 7 Side View Sheet 1 of 2 ...