ELECTRO FREEZE Shake Model CS700-FG
185231-17
27
12 Routine Maintenance
Electro Freeze recommends the following
schedule to help maintain your equipment
in like-new operating condition. Take the
time to learn and perform these routine
procedures and receive in return many
years of valuable service from your
freezer. Protect your investment.
DAILY
1. Disassemble, wash, rinse,
sanitize, air dry, reassemble and sanitize
all parts that come into contact with the
mix or product.
CAUTION
To prevent bacteria growth,
remove all O-rings when cleaning.
Failure to do so could create a
health hazard.
2. Clean the cylinder and drain tube
with the appropriate brushes.
3. Upon cleaning, inspect and
lubricate all seals and O-rings as
instructed that come into contact with mix.
Replace any O-ring that is worn, torn, or
loose-fitting.
4. Wipe all exterior surfaces of the
freezer to remove any splattered mix.
5. Check overrun and temperature
of the product.
WEEKLY
1. Carefully inspect all parts
for wear including, seals, O-rings,
mix transfer tube and blades.
2. Replace as required.
Replace blades if worn 3/16” or
more.
3. Check the beater tangs
and drive shaft for wear.
A worn coupling will have a
nonparallel shape on the drive
opening.
4. Check the air filter
and clean as necessary. After
cleaning apply spray adhesive, p/n
HC162548.
Содержание CS700-FG
Страница 2: ......
Страница 7: ...ELECTRO FREEZE Shake Model CS700 FG Safety Decal Locations v 1 P N HC165126 2 P N HC165025 ...
Страница 10: ......
Страница 16: ...ELECTRO FREEZE Shake Model CS700 FG 185231 17 6 4 Part Names and Functions Figure 4 1 Head Assembly ...
Страница 46: ......
Страница 48: ......
Страница 54: ...ELECTRO FREEZE Shake Model CS700 FG 185231 17 6 Figure 7 Side View Sheet 1 of 2 ...