Slush Freezer
Troubleshooting Chart
* ON FREEZERS WITH AUTO-FILL SYSTEM, BRIX FILL STATION TO PRODUCT SUPPLIERS RECOMMENDATION (MINIMUM 11% BRIX).
CHECK TO SEE
IF BOTTOM
TORQUE
SPRING IS
ATTACHED
CHECK PRODUCT BRIX
ADJUST TO 11-13% BRIX*
CHECK MIX SUPPLY
KEEP HOPPER FILLED MUST
BE ABOVE
1/3 FULL
MAKE SURE
ADJUSTMENT
SCREW IS IN LINE
WITH TORQUE
SWITCH
OPERATOR COMPLAINT IS:
“PRODUCT IS TOO THICK” or "WILL NOT DISPENSE"
IF PROBLEM PERSISTS
CONTACT H. C. DUKE & SON, INC. / ELECTRO FREEZE
SERVICE DEPARTMENT AT
800/755-4545
IF PROBLEM PERSISTS
CONTACT H. C. DUKE & SON, INC. / ELECTRO FREEZE
SERVICE DEPARTMENT AT
800/755-4545
OPERATOR COMPLAINT IS:
“FREEZER VIBRATES OR ROCKS EXCESSIVELY”
CHECK MIX
SUPPLY
KEEP HOPPER
FILLED
MUST BE ABOVE
1/3 FULL
CHECK PRODUCT
BRIX ADJUST TO
11-13% BRIX*
CHECK
SCRAPER
BLADES
IF WORN
REPLACE
CHECK TO
SEE IF
FREEZER IS
LEVEL AND
ALL 4
CASTERS
ARE
ADJUSTED
PROPERLY
TURN ADJUSTMENT SCREW
¼ TURN CLOCKWISE
WAIT 30 MINUTES
RECHECK