MAINTENANCE 

CLEANING 

Please shut off the unit and unplug from the mains before cleaning or performing any 
maintenance

 

CLEAN THE SURFACE 

Clean the plastic housing with a duster or a soft wet cloth.   
Do  not  use  chemical  solvents  (such  as  benzene,  alcohol  or  gasoline)  as  they  may  cause 
irreversible damage. 

 

AIR FILTER CLEANING

 

a) 

Clean the air filters every 2 weeks. If the air filter is blocked 

with dust, the unit’s performance will be significantly affected.

   

b) 

Disconnect  the  power  plug  from  the  socket  before 

dismantling, assembling or cleaning 

c) 

Open  the  air  filter  covers  and  remove  the  carbon  (if 

installed) and washable mesh filter 

d) 

Hoover gently the carbon filter and do not wash 

e) 

Wash  the  mesh  air  filters  by  immersing 

them  in  warm  (about  40

)  water  with  a 

neutral detergent. 

f) 

Rinse it and then dry it thoroughly. 

g) 

Carefully re-install air filters back into their cover 

 

Please note

: If in use, the optional active carbon filter (cloth) should be replaced every 3-6 

months based on the environment.

       

 

END OF SEASON MAINTENANCE

 

1. 

Pull out the plug from the drainage hole and empty the internal tank. You can also drain the 
water by leaning the unit. 

2. 

Then switch the unit to low fan mode.   

3. 

Keep the unit in this mode for half day - until the conduit is dried. Doing this helps to keep 
the inside of the unit dry and prevents mould developing 

4. 

Turn off the unit and pull out the plug. 

 

5. 

Coil the wire and bind it together, then put it into the accessories space. 

6. 

Separate the air-exhausted pipe and store it safely.

   

7. 

Cover the unit and keep it in a dry place. 

8. 

Take the batteries out of remote control and store, or dispose, them safely   

Keep all accessories with the unit ready for next season.

 

 

 

Содержание P16HP

Страница 1: ...ITH HEATPUMP P16HP P18HP Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co...

Страница 2: ...Page 2 of 15 CONTENTS SAFETY INSTRUCTIONS 3 FEATURES AND PARTS LIST 5 INSTALLATION 7 OPERATION AND SETTINGS 9 WATER DRAINAGE 11 MAINTENANCE 12 TROUBLESHOOTING 13 APPENDIX 14...

Страница 3: ...nit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be installed by a qualified electrician Neve...

Страница 4: ...authorized technicians Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer Before opening and servicing the unit the authorized engineer must be in posses...

Страница 5: ...LED screen indicates temperature and operation mode Enhanced design with hot air outlet positioned higher This allows for improved performance with the use of a short hose 24 hour programmable timer...

Страница 6: ...Page 6 of 15 PARTS LIST ACCESSORIES Rear cover SIDE VIEW Castor FRONT VIEW Control Panel REAR VIEW Plug Air Inlet Exhaust Hose Fishtail Connector Slide Bar Remote Control Exhaust hose connector...

Страница 7: ...he end of the hose and twisting the fishtail into position At least 3 full rotations 2 Assemble the Exhaust hose connector on to the other end of the hose by extending the opposite end of the hose and...

Страница 8: ...indow However the fish tail adaptor can be used with most windows doors When using cooling or heating modes ensure that the opening is left as small as possible The best form of installation is throug...

Страница 9: ...The unit should be set up without a vent hose moisture is extracted from the air that passes through the unit Continuous drainage should be set up for the moisture collected FAN MODE No cooling effec...

Страница 10: ...number of hours time you desire the unit to start by using the UP and DOWN buttons 2 Once the set time has elapsed the unit will turn on automatically 3 Press the POWER button before the time has elap...

Страница 11: ...o place CONTINUOUS DRAINAGE 1 Unscrew the water plug A and remove the rubber bung B 2 Connect a suitably sized water pipe to the port 3 You can plumb this pipe into your current plumbing system lead i...

Страница 12: ...about 40 water with a neutral detergent f Rinse it and then dry it thoroughly g Carefully re install air filters back into their cover Please note If in use the optional active carbon filter cloth sho...

Страница 13: ...e The unit loud The unit is not put on flat surface Put the unit on flat and hard surface Compressor does not work Overheating protection is active Check venting Restart the unit after 5 minutes when...

Страница 14: ...ur local household waste recycling centres TECHNICAL DATA P16HP P18HP Capacity Cooling 4 6 kWh 16 000 BTU Cooling 5 2 kWh 18 000 BTU Heating 4 2 kWh 14 000 BTU Heating 4 7 kWh 16 000 BTU Rated Input C...

Страница 15: ...1 620 1057 or complete the online form 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to s...

Отзывы: