SLEEP MODE 

Press the SLEEP button to enter sleep mode, the default fan speed is low and the Sleep 
mode indicator led will illuminate.   
 
When the sleep mode is turned on: 
 
After one hour the set temperature will increase by 1 degree Celsius, after another hour 
the set temperature will increase by another degree, and will then remain set at that 
temperature.   
 
Please note:     

 

Sleep mode cannot be used in dry and fan modes.   

 

If internal tank becomes full, the machine will turn off and sleep mode will be 
cancelled. 

 
SWING BUTTON

 

After machine is on and mode selected, press this button and the louver will swing 
continuously up and down; by pressing this button again the movement will stop and the 
louver remain fixed in position. 

 
TIMER BUTTON

 

 

The in-built timer will allow you to set the unit to turn on or turn off after a set period of 
time, Please note only one timer can be used at any time. 

 
ON TIMER

 – The timer will turn on the unit automatically after the time set has elapsed. 

1. 

With the unit turned off, press the TIMER button, then set the number of hours’ time 
you desire the unit to start by using the UP and DOWN buttons. 

2. 

Once the set time has elapsed, the unit will turn on automatically. 

3. 

Press the POWER button before the time has elapsed and the unit will turn on as 
normal and the timer will be cancelled 

4. 

The function and fan speed can be set whilst setting the timer. 
 

OFF TIMER

 – The timer will turn off the unit automatically after the time set has elapsed. 

1. 

While the unit is operating, press the TIMER button then set the number of hours’ 
time you desire the unit to stop by using the UP and DOWN buttons. 

2. 

Once the set time has elapsed, the unit will turn off automatically. 

3. 

Press the POWER button before the time has elapsed, the setting time will be 
cancelled and the unit will turn off. 

 
TANK FULL INDICATOR 

When the internal water tank is full, the unit will stop operation, and the TANK FULL 
indicator will illuminate.    To restart operation, empty the water tank following the 
information in the Water drainage section 

 
LED DISPLAY

 

The display indicates the current target temperature or the remaining timer settings. When 
the set temperature or the timer is adjusted, the new setting is shown. 
The display is also used to show error codes. Should a fault occur, see ERROR CODES. 
 

 

 

Содержание P16HP

Страница 1: ...ITH HEATPUMP P16HP P18HP Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co...

Страница 2: ...Page 2 of 15 CONTENTS SAFETY INSTRUCTIONS 3 FEATURES AND PARTS LIST 5 INSTALLATION 7 OPERATION AND SETTINGS 9 WATER DRAINAGE 11 MAINTENANCE 12 TROUBLESHOOTING 13 APPENDIX 14...

Страница 3: ...nit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be installed by a qualified electrician Neve...

Страница 4: ...authorized technicians Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer Before opening and servicing the unit the authorized engineer must be in posses...

Страница 5: ...LED screen indicates temperature and operation mode Enhanced design with hot air outlet positioned higher This allows for improved performance with the use of a short hose 24 hour programmable timer...

Страница 6: ...Page 6 of 15 PARTS LIST ACCESSORIES Rear cover SIDE VIEW Castor FRONT VIEW Control Panel REAR VIEW Plug Air Inlet Exhaust Hose Fishtail Connector Slide Bar Remote Control Exhaust hose connector...

Страница 7: ...he end of the hose and twisting the fishtail into position At least 3 full rotations 2 Assemble the Exhaust hose connector on to the other end of the hose by extending the opposite end of the hose and...

Страница 8: ...indow However the fish tail adaptor can be used with most windows doors When using cooling or heating modes ensure that the opening is left as small as possible The best form of installation is throug...

Страница 9: ...The unit should be set up without a vent hose moisture is extracted from the air that passes through the unit Continuous drainage should be set up for the moisture collected FAN MODE No cooling effec...

Страница 10: ...number of hours time you desire the unit to start by using the UP and DOWN buttons 2 Once the set time has elapsed the unit will turn on automatically 3 Press the POWER button before the time has elap...

Страница 11: ...o place CONTINUOUS DRAINAGE 1 Unscrew the water plug A and remove the rubber bung B 2 Connect a suitably sized water pipe to the port 3 You can plumb this pipe into your current plumbing system lead i...

Страница 12: ...about 40 water with a neutral detergent f Rinse it and then dry it thoroughly g Carefully re install air filters back into their cover Please note If in use the optional active carbon filter cloth sho...

Страница 13: ...e The unit loud The unit is not put on flat surface Put the unit on flat and hard surface Compressor does not work Overheating protection is active Check venting Restart the unit after 5 minutes when...

Страница 14: ...ur local household waste recycling centres TECHNICAL DATA P16HP P18HP Capacity Cooling 4 6 kWh 16 000 BTU Cooling 5 2 kWh 18 000 BTU Heating 4 2 kWh 14 000 BTU Heating 4 7 kWh 16 000 BTU Rated Input C...

Страница 15: ...1 620 1057 or complete the online form 1 Has the unit been standing upright for at least 2 hours 2 Is the unit plugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to s...

Отзывы: