ElectrIQ IQOOLSMART12HP-WiredCtrl Скачать руководство пользователя страница 3

3

 

 

INSTALLATION

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

Use the screws provided (M4x25) to fix  the controller backing plate onto the 
wall, ensuring that it is securely connected before proceeding. Depending on the 
type of wall, suitable fixings should be purchased.  

 

NOTE

: Do not overtighten the screws, as this may cause the backing plate to 

distort or break. 

   

Remove the wired controller from the backing plate using 
a flat headed screwdriver in the gap between the backing 
plate and the controller. Once the two parts are 
separated, the remainder can be unclipped. 

Pass the signal wire through the opening in the rear of the 
backing plate, ensuring it is positioned so it will not be 
trapped or damaged during installation. Allow enough cable 
to pass through for ease of installation and future 
maintenance. 

 

Connect the signal wire between the wired controller 
and the air conditioner. The cable with the connector 
for the controller is fixed to the rear of the air 
conditioner. 

 

 

If the signal cable provided is too short it can 
be replaced with suitable 5-core shielded 
cable up to a maximum length of 20m. 

Отзывы: