HINTS FOR EXHAUST DUCT INSTALLATION 

The following rules must be strictly followed to obtain optimal air extraction: 
• Keep expansion pipe short and straight. 
• Do not reduce the size or restrict expansion pipe. 
• When using expansion pipe always install the pipe pulled taut to minimize pressure 
loss. 
• Failure to observe these basic instructions will reduce the performance and increase 
noise levels of the cooker hood. 
• Any installation work must be carried out by a qualified electrician or competent 
person. 
•Do not connect the ducting system of the hood to any existing ventilation system 
which is being used for any other appliance ,such as warmer tube, gas tube , hot wind 
tube. 
•The angle of the bend of the expansion pipe should not be less than 120º; you must 
direct the pipe horizontally, or, alternatively, the pipe should go up from the initial point 
and should be led to an outer wall. 
•After the installation ,make sure that the cooker hood is level to avoid grease 
collection at on end. 
•Ensure the expansion pipe selected for installation complies with relevant standards 
and is fire retardant. 

 

 

                        

                  

    

START USING YOUR COOKER HOOD

 

 

 
  
 

 

 

 
1. 

Press the “Power” button, to turn the cooker hood on and off.   

 
2. 

Use    the  “Increase”or  “Decrease”  buttons  to  cycle  between  fan  speeds,  the  LED 
display will indicate the fan speed with the numbers 1, 2 and 3. 

 
3. 

Press “Light” button to turn the hoods light on and off. 

 

   LIGHT                 DECREASE            DISPLAY               INCREASE             POWER 

Содержание eiQ60touchslimhe

Страница 1: ...OL COOKER HOOD eiQ60touchslimhe eiQ90touchslimhe Thank you for choosing electriQ Please read this user manual before using this product and keep it safe for future reference Visit our page www electri...

Страница 2: ...TENTS SAFETY 3 PRODUCT OVERVIEW 5 VENTILATION 6 INSTALLATION 7 OPERATION 9 FILTER CLEANING AND REPLACEMENT 10 BULB REPLACEMENT 11 CLEANING AND MAINTENANCE 11 TROUBLESHOOTING 12 SUPPORT 12 PRODUCT FICH...

Страница 3: ...cessively greasy They should be cleaned regularly see Maintenance or replaced as necessary The extraction fan must be level to avoid grease collection at one end as this could cause a potential fire r...

Страница 4: ...ugh a suitable sized opening which cannot be sealed during operation A number of alternative solutions are available to ensure this If in any doubt professional advice should be sought Regulations con...

Страница 5: ...5 PRODUCT OVERVIEW...

Страница 6: ...dy The images only show an example of how to mount the V flap the outlet may be various according to different models and configuration To mount the V flap 1 you should 1 Mount two half parts 2 into t...

Страница 7: ...means of an extraction duct enamel aluminum flexible pipe or non flammable material with an interior diameter of 150mm 1 Before installation turn the unit off and unplug it from the outlet 2 The cooke...

Страница 8: ...e chimney with 2 pcs ST4 8mm screws and be sure that the inside chimney can be adjusted the height in it freely Afterwards install chimneys on the cooker hood Lay the expansion pipe to the wall outlet...

Страница 9: ...for any other appliance such as warmer tube gas tube hot wind tube The angle of the bend of the expansion pipe should not be less than 120 you must direct the pipe horizontally or alternatively the pi...

Страница 10: ...r cooking habit The installation procedure of activated carbon filter is as below Replacements are available from the retailer the hood was purchased from under reference eiqmidcarbon 1 The aluminum f...

Страница 11: ...ut the light wire If the light wire cannot be pulled out it can be cut directly with scissors Apply the reverse procedure to install the light back ILCOS D code for this lamp is DSS 1 5 S 70 MAX WATTA...

Страница 12: ...ht does not work motor does not work House fuses blown Reset Replace fuses Power cord loose or disconnected Refit cord to power outlet Switch power outlet on Oil leakage One way valve and the outlet a...

Страница 13: ...AM 5PM Monday to Friday www electriQ co uk Unit J6 Lowfields Business Park Low elds Way Elland West Yorkshire HX5 9DA Recycling facilities are now available for all customers at which you can deposit...

Страница 14: ...nt PBEP 264 Pa Maximum air flow Qmax 480 3 m3 h Measured electric power input at best efficiency point WBEP 61 8 W Nominal power of the lighting system WL 3 0 W Measured power of the lighting system W...

Отзывы: