4
Energy Saving and Unit Safety Protection Tips
Do not cover or restrict the airflow from the outlet or inlet grills.
For maximum performance the minimum distance from a wall or objects should be 50cm.
Keep the filters clean. Under normal conditions, filters should only need cleaning once
every four weeks (approximately). Since the filters remove airborne particles, more frequent
cleaning maybe necessary, depending on the air quality.
For the initial startup set the fan speed to maximum and the thermostat to 4-5 degrees
lower than the current temperature. After, set the fan switch to low and set the thermostat to
your desired setting.
To protect the unit we recommend not using the cooling function when the ambient indoor
temperature is higher than 35
℃
.
To protect the unit we recommend not using the heating function when the indoor ambient
temperature is lower than 7
℃
.
Note the manufacturer operating temperature ranges at the end of this user manual.
OPERATION
Cooling Mode
The compressor (6) in the exterior unit compresses the
refrigerant into a high- temperature, high-pressure gas. When
this gas flows along the cooling fins of the condenser (7),
heat is exuded and the gas condenses into a liquid, which is
led to the evaporator (1) in the interior unit. The liquid
expands into a gas at a low temperature and low pressure is
converted.
This gas absorbs the warmth of the air in the room, the
cooled air is blown back into the room and the heat is
moved to the compressor along with the gas.
A fan (3) draws the air over the filter and blows the cooled
air back into the room. A fan (8) draws air over the
condenser and blows warm air away.
1. Evaporator 2. Filter 3. Evaporator Fan 4. Gas Line 5. Liquid line
6. Compressor 7. Condenser 8. Condenser Fan
Heat Pump Mode
The system operates in reverse: the condenser works as an evaporator, the evaporator as
a condenser: warm air is blown into the room. It is ideal as a maintenance heating when
outside temperature is not too low and when indoor temperature is more than 7
°
C.
Dehumidifying
As with cooling, the moisture in the air condenses on the cold evaporator at room
temperature acting as a powerful dehumidifier.
3
2
1
2
4
2
5
2
6
4
2
8
2
7
2
Содержание eIQ-12WMINV
Страница 11: ...11 ...
Страница 15: ...15 ...
Страница 22: ...22 ELECTRICAL WIRING DIAGRAMS eIQ 9WMINV Indoor Unit Outdoor Unit QC ...
Страница 23: ...23 ELECTRICAL WIRING DIAGRAMS eIQ 12WMINV QC Indoor Unit Outdoor Unit ...
Страница 24: ...24 ELECTRICAL WIRING DIAGRAMS eIQ 18WMINV Indoor Unit Outdoor Unit QC ...
Страница 25: ...25 ELECTRICAL WIRING DIAGRAMS eIQ 24WMINV Indoor Unit Outdoor Unit ...