ElectrIQ eIQ-12WMINV Скачать руководство пользователя страница 23

 

 

23 

ELECTRICAL WIRING DIAGRAMS- eIQ-12WMINV(QC)                                                                                             

 

Indoor 
Unit

 

Outdoor Unit

 

  

Содержание eIQ-12WMINV

Страница 1: ...INV 12 000 BTU eIQ 18WMINV 18 000 BTU eIQ 24WMINV 24 000 BTU also quick connectors QC models Thank you for choosing ElectrIQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electrIQ co uk for our entire range of Intelligent Electricals ...

Страница 2: ...F SEASON 8 REPLACING THE BATTERIES 8 INSTALLATION GUIDE 9 INSTALLATION OF THE OUTDOOR UNIT 16 STANDARD PIPELINES CONNECTION AIR PURGING 16 QUICK CONNECTORS OUTDOOR UNIT INSTALLATION WMINVQC MODELS 18 ELECTRICAL WIRING DIAGRAMS 22 TROUBLESHOOTING AND SELF DIAGNOSIS 26 TECHNICAL SPECIFICATIONS 27 APPENDIX 28 ...

Страница 3: ...intended for use by those with a lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety Do not leave children unsupervised with this appliance Do not clean the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord Both the indoo...

Страница 4: ...sor 6 in the exterior unit compresses the refrigerant into a high temperature high pressure gas When this gas flows along the cooling fins of the condenser 7 heat is exuded and the gas condenses into a liquid which is led to the evaporator 1 in the interior unit The liquid expands into a gas at a low temperature and low pressure is converted This gas absorbs the warmth of the air in the room the c...

Страница 5: ...appliance on with the ON OFF button This activates the most recent used setting The ON OFF button turns the air con off TEMPERATURE The desired temperature is set with the up and or down button within the limits of the thermostat 16 C 32 C Use the FAN SPEED button to set the fan speed at low medium and high or automatic the symbol on the display will flash The fan speed in the automatic setting is...

Страница 6: ...t the desired temperature 3 Use the FAN button to set the fan speed 4 Press the timer off button to set the time Use the up and down button to choose from 1 24 hours timer setting Once the time you have set has elapsed the appliance will switch itself off To cancel the timer off function before the set time has elapsed press the timer off button again Timer on function while air conditioner is in ...

Страница 7: ...e metre of floor surface In strong sunlight or if other sources of heat are present this may be as much as 350 W sqm Tip on warm days let the air conditioner cool the room as much as possible during the night and set the temperature constant from night to daytime Emergency start In the event of a problem the air conditioner can be operated using the emergency button under the panel in the interior...

Страница 8: ...e of debris etc Cleaning with chemicals may cause damage END OF SEASON If the air conditioner is not going to be used for an extended period set in fan mode on a slightly warm day so that the inside of the appliance dries out switch of the power from fuse box and remove the batteries from the remote control clean filters as well START OF SEASON If the air conditioner is to be used again after an e...

Страница 9: ...onnel only Always make sure to wear the correct personal safety protections such as protective eyewear gloves ear protection etc This air conditioner contains a refrigerant and can be classified as pressurized equipment Therefore always contact an authorized air conditioning engineer for installation and maintenance of the air conditioner The air conditioner must be inspected and serviced on an an...

Страница 10: ...power voltage making sure the correct sized power cables are used 2 The appliance shall be installed in accordance with standard wiring regulations by qualified personnel 3 Only replace fuses according to their printed rating or corresponding pcb boards RECOMMENDED INSTALLATION SPACING DIAGRAM ...

Страница 11: ...11 ...

Страница 12: ...l Screwdrivers Core hole cutter Number 14 7mm masonry drill 1 5 inch number 10 screws roundhead slotted 7mm wallplugs Pipe cable detector Hammer Tape measure Spirit level Pencil and chalk Small stepladder Protective glasses and mask 4 inch plastic ties ...

Страница 13: ...13 Also the following 2 inch Pipe clips Circuit breaker when drilling inside and out Garden gloves when lifting the outdoor unit Dustsheets Foam Filler Silicone sealer and gun ...

Страница 14: ...Check level mark the other holes and swing the backplate away 7 Drill the rest of the holes and tap in wallplugs 8 Fix the backplate to the wall 9 Mark the hole centre make sure the 3 5 inch cutter will clear the backplate 10 Drill the hole at a slight downward angle When you feel the pilot drill exit the outside wall stop 11 Finish the hole from the outside to keep it clean 12 Feed the cord and d...

Страница 15: ...15 ...

Страница 16: ...ce 3 Try to reduce the bending of the pipes as much as possible so as to avoid possible negative impacts upon the performances of the unit For the quick connectors model the pipes and electrical cables will be encased in a plastic umbilical cord but there will still be need for careful handling of the piping to avoid bends INSTALLATION OF THE OUTDOOR UNIT Try to move the product to the installatio...

Страница 17: ...e pressure in them lowers to below 1 5mmHG The operation time for vacuuming is about 10 minutes When the desired vacuum is reached close the valve of the low pressure of the manifold and stop the vacuum pump 3 Disconnect the service hoses and fit the cap to the charging valve 4 Remove the blank caps and fully opens the spindles of the 2 way and 3 ways valves with a service valve wrench 5 Tighten t...

Страница 18: ...18 QUICK CONNECTORS OUTDOOR UNIT INSTALLATION eIQ 12WMINVQC Installation of the eIQ 12WMINVQC is faster and required less tools There is no need to use a vacuum pump ...

Страница 19: ...he lug 6 Push the electrical snap connector together 7 Connect the 3 wires to the terminal board Clip on the raincover and 8 fasten the retaining screw 9 Fold the excess cord back on itself and clip it with plastic ties 10 Screw down the unit You will need four washers not supplied 11 Fix the cord and drain hose to the wall 12 Switch on at the mains run test and check for any coolant or water leak...

Страница 20: ...the handle seals behind the Release Sleeve and flat against the entire coupling assembly Step 1 Shut down the A C unit and unplug the electrical power cord from the wall outlet Step 2 Wait five minutes for the line pressure between the indoor compressor unit and outdoor condensing unit to equalize Step 3 Pull the male coupling handle up and toward the male coupling to the full back position Step 4...

Страница 21: ...ipes vertical before extending Please do not extend only one side of the packed soft pipes Please make use of semicircle pulley to keep the allowed bending angle Extremely bending could damage the pipes Please use a twisting wheel to avoid improper bending Over bent soft pipes will lead to irregular bending Please use rigid elbow to keep the bending angle while soft pipes operating Undersize bendi...

Страница 22: ...22 ELECTRICAL WIRING DIAGRAMS eIQ 9WMINV Indoor Unit Outdoor Unit QC ...

Страница 23: ...23 ELECTRICAL WIRING DIAGRAMS eIQ 12WMINV QC Indoor Unit Outdoor Unit ...

Страница 24: ...24 ELECTRICAL WIRING DIAGRAMS eIQ 18WMINV Indoor Unit Outdoor Unit QC ...

Страница 25: ...25 ELECTRICAL WIRING DIAGRAMS eIQ 24WMINV Indoor Unit Outdoor Unit ...

Страница 26: ... Outdoor coil temp sensor fault F7 7 Lighten 4 Compressor suction temp sensor fault F8 8 Lighten 5 Compressor discharge temp sensor fault F9 9 Lighten 6 Inductor of current or voltage fault FA 10 Lighten 7 Compressor drive abnormal fault FC 11 Lighten 8 Power supply phase lacking or phase sequence fault FD 12 Lighten 9 Return air sensor abnormal Include these roads A B C D FE 13 Lighten 10 Other f...

Страница 27: ...6 A 3 8 A 5 6 A 4 0 A Nominal load kW 2 6 2 5 QC 2 6 2 4 QC 3 5 5 1 5 1 7 0 7 0 Balance point temperature Heating 7 7 7 7 Min outdoor operating temperature 10 10 10 10 Thermostat off mode W 29 29 66 80 Standby mode W 0 5 0 5 0 5 0 5 Off mode W 0 0 0 0 Annual consumption kW 143 15 6 QC 910 88 4 QC 204 293 1879 438 2450 Copper Pipe Type length 5 meters 4 meters QC 5 meters 4 meters QC 5 meters 4 met...

Страница 28: ...ng Automatic defrosting Automatic defrosting Automatic defrosting Applicable climate types T1 typical 7 C 43 C T1 typical 7 C 43 C T1 typical 7 C 43 C T1 typical 7 C 43 C Due to continuous product development process specification may change These units contain a gas governed by F Gas regulations The gas must be handled by qualified F Gas engineers APPENDIX Disposal Do not dispose this product as ...

Страница 29: ...on will render this WARRANTY VOID This warranty is in addition to and does not affect your statutory rights Our warranty is RTB warranty and cover parts and our labour only We recommend that you note the details of your purchase below and retain your original proof of purchase receipt with this manual Keep these documents safe in the event of a warranty claim Purchase Date ________________________...

Страница 30: ...eck the troubleshooting guide before calling the service line If the unit still fails to operate call 0871 620 1057 or complete the online form Office hours 9AM 5PM Monday to Friday www ElectrIQ co uk Unit 2 The Nursery Berristow Lane South Normanton Derbyshire DE55 2FX ...