ElectrIQ CD12LEB Скачать руководство пользователя страница 3

 

 

 

SAFETY INSTRUCTIONS  

 

IMPORTANT  

 

Carefully read the instructions before operating the unit  

 

This appliance is for indoor use only and intended for use in a domestic environment 
only.  Any  other  use  is  not  recommended  by  the  manufacturer  and  may  cause  fire, 
electrical shocks or other injuries to user or property.  

 

Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet.  

 

Installation must be in accordance with the regulations of the country where the unit 
is used.  

 

If you are in any doubt about the suitability of your electrical supply, have it checked 
and if necessary, modified by a qualified electrician.  

 

This dehumidifier has been tested and is safe to use. However, as with any electrical 
appliance - use it with care.  

 

Disconnect the power before dismantling, assembling or cleaning.  

 

Avoid touching any moving parts of the appliance.   

 

Never insert fingers, pencils or any other objects though the guard   

 

This appliance is not intended for  use by persons (including children) with reduced 
physical, sensory or mental capabilities. It is also not intended for use by those with a 
lack  of  experience  and  knowledge  unless  they  have  been  given  supervision  or 
instruction concerning the use of the appliance by a person responsible for their safety.   

 

Do not leave children unsupervised with this appliance.  

 

Do not clean the unit by spraying it or immersing it in water.   

 

Never connect the unit to an electrical outlet using an extension cord. If a power outlet 
is not available, one should be installed by a qualified electrician.  

 

Never operate this appliance if the cord, power adapter or plug is damaged. Ensure 
the power cord is not stretched or exposed to sharp objects/edges.  

 

A damaged power supply cord should be replaced by the manufacturer or a qualified 
electrician in order to avoid a hazard. 

 

Any service other than regular cleaning or filter replacement should be performed by 
an  authorized  service  representative.  Failure  to  comply  could  result  in  a  voided 
warranty.  

 

Do not use the appliance for any purpose other than its intended use.  

 

Do not tilt the unit while in use. The unit is designed to work only in a vertical position.  

 

This  dehumidifier  must  always  be  stored  and  transported  upright,  otherwise 
irreparable damage may be caused to the compressor; if in doubt we suggest waiting 
at least 24 hours before starting the unit.  

 

Avoid restarting the dehumidifier  unless 5 minutes  have passed since being turned 
off. This prevents damage to the compressor.  

 

Never use the plug as a switch to start or turn off the dehumidifier. Use the provided 
ON/OFF switch located on the control panel.  

 

Always place the unit on a dry and stable surface.  

 

The appliance should not be installed in laundry or wet rooms where the humidity is 
higher than 85% RH  

 

Do  not  dry  laundry  above  the  unit  to  prevent  water  from  entering  the  dehumidifier. 
Place the laundry at least 1 meter away from your dehumidifier.   

 

Before moving the appliance, the water tank should be emptied.  

Содержание CD12LEB

Страница 1: ...R PURIFIER CD12LEB 12 Litres per day CD20LEB 20 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier and keep it safe for future refere...

Страница 2: ...1 CONTENTS SAFETY INSTRUCTIONS 2 INSTALLATION 5 PARTS 6 CONTROL PANEL 7 QUICK REFERENCE GUIDE 8 POSITIONING 11 WATER DRAINAGE 12 CARE AND MAINTENANCE 12 TROUBLESHOOTING 14 TECHNICAL DATA 15...

Страница 3: ...r connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate this appliance if the cord power...

Страница 4: ...y qualified engineer Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer s service manual and must follow the safety information contained...

Страница 5: ...4 QUICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER...

Страница 6: ...adjusted in increments of 5 between 40 and 80 ensuring your room is not dried too much and power is not wasted FEATURES Your dehumidifier belongs to the electriQ low energy premium dehumidifiers featu...

Страница 7: ...ed carbon filter Optional Louvres 1 Air Outlet 3 2 Handle 4 Humidity Indicator light Wheels 5 6 Control Panel 7 Pre filter activated 8 Air inlet Carbon filter 9 Continuous Drain Port 10 Back Cover 11...

Страница 8: ...d aim for the humidity set using the up and down buttons FAN Only the fan will run and water is not extracted Use with the UV function for improved air purification HUMIDITY INDICATOR MODE When the ap...

Страница 9: ...e is running with the desired settings press the TIMER button then use the UP and DOWN buttons to set in how many hours time you require the unit to stop 0 24 hours INTELLIGENT DEFROST The appliance w...

Страница 10: ...e room ensuring the entire air in the room is processed and humidity correctly measured To achieve drier air or while drying laundry put the unit in High mode and use the down button to select a lower...

Страница 11: ...the fan will continue to operate to ensure that the air within the room is not stale The unit will use only a minimal amount of energy in fan mode When the humidity of the room is equal to or higher...

Страница 12: ...on for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and...

Страница 13: ...ll the way into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove any parts from the water tank or tank enclosur...

Страница 14: ...e NOTE Do not use a dishwasher to clean the tank After cleaning and drying the tank must be reinserted securely into dehumidifier in order to restart operation END OF SEASON MAINTENANCE 1 Empty and cl...

Страница 15: ...tructions and restart the unit Ensure a distance of at least 20 cm between the unit walls Airflow seems weak Is filter dirty or clogged Please service the filters regularly as per user manual Unit is...

Страница 16: ...gs 14 14 3 GWP 3 3 All information provided is for reference only Products specifications may change due to continuous product development Disposal Do not dispose of this product as unsorted waste Col...

Страница 17: ...ugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if the issue is resolved Restart the unit 5 Check if the water tank is full 6 Was the troubleshooting guide fo...