ElectrIQ CD12LEB Скачать руководство пользователя страница 16

15 

 

 

 

TECHNICAL DATA  

Model 

 

CD12LEB

 

CD20LEB

 

Voltage 

 

1Ph, 220-240V

50Hz 

 

1Ph, 220-240V

50Hz 

 

Dehumidifying capacity 

 

12 L / day  

 

(at 30⁰ C / 80%RH) 

 

20 L / day  

 

(at 30⁰ C / 80%RH) 

 

Fan Speeds 

 

 

 

Power Consumption 

 

180W 

 

270W 

 

Running Amps 

 

0.91 Amps 

 

1.2 Amps 

 

Tank Capacity 

 

4 litres 

 

4 litres 

 

Humidity settings range 

 

35%

80% 

 

35%

80% 

 

IP RATING 

 

IPX1 

 

IPX1 

 

Refrigerant 

 

R290, 60 grams 

 

R290, 75 grams 

 

Airflow m3/h 

 

180

 

180

 

High / Low Pressure  

 

1.5/0.5MPa 

 

1.5/0.5MPa 

 

Max noise level dB(A) 

 

42-49 

 

42-49 

 

Filters 

 

carbon (optional) 

 

carbon (optional) 

 

Dimensions mm  

 

(WxDxH) 

 

380x580x195 

 

380x580x195 

 

Weight kgs           

 

14 

 

14.3 

 

GWP 

 

3

 

3

 

All  information  provided  is  for  reference  only.  Products  specifications  may 
change due to continuous product development. 

 

 

 

Disposal: Do not dispose of this product as unsorted waste. Collection of such waste must be handled 

separately as special treatment is necessary. 

 

 

 

Recycling facilities are now available for all customers at which you can deposit your old electrical products. 

Customers will be able to take any old electrical equipment to participating sites run by their local councils. 

Please remember that this equipment will be further handled during the recycling process, so please be 

considerate when depositing your equipment. Please contact the local council for details of your local 

household waste recycling centres. 

 

 

 

 

 

Содержание CD12LEB

Страница 1: ...R PURIFIER CD12LEB 12 Litres per day CD20LEB 20 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier and keep it safe for future refere...

Страница 2: ...1 CONTENTS SAFETY INSTRUCTIONS 2 INSTALLATION 5 PARTS 6 CONTROL PANEL 7 QUICK REFERENCE GUIDE 8 POSITIONING 11 WATER DRAINAGE 12 CARE AND MAINTENANCE 12 TROUBLESHOOTING 14 TECHNICAL DATA 15...

Страница 3: ...r connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate this appliance if the cord power...

Страница 4: ...y qualified engineer Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer s service manual and must follow the safety information contained...

Страница 5: ...4 QUICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER...

Страница 6: ...adjusted in increments of 5 between 40 and 80 ensuring your room is not dried too much and power is not wasted FEATURES Your dehumidifier belongs to the electriQ low energy premium dehumidifiers featu...

Страница 7: ...ed carbon filter Optional Louvres 1 Air Outlet 3 2 Handle 4 Humidity Indicator light Wheels 5 6 Control Panel 7 Pre filter activated 8 Air inlet Carbon filter 9 Continuous Drain Port 10 Back Cover 11...

Страница 8: ...d aim for the humidity set using the up and down buttons FAN Only the fan will run and water is not extracted Use with the UV function for improved air purification HUMIDITY INDICATOR MODE When the ap...

Страница 9: ...e is running with the desired settings press the TIMER button then use the UP and DOWN buttons to set in how many hours time you require the unit to stop 0 24 hours INTELLIGENT DEFROST The appliance w...

Страница 10: ...e room ensuring the entire air in the room is processed and humidity correctly measured To achieve drier air or while drying laundry put the unit in High mode and use the down button to select a lower...

Страница 11: ...the fan will continue to operate to ensure that the air within the room is not stale The unit will use only a minimal amount of energy in fan mode When the humidity of the room is equal to or higher...

Страница 12: ...on for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and...

Страница 13: ...ll the way into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove any parts from the water tank or tank enclosur...

Страница 14: ...e NOTE Do not use a dishwasher to clean the tank After cleaning and drying the tank must be reinserted securely into dehumidifier in order to restart operation END OF SEASON MAINTENANCE 1 Empty and cl...

Страница 15: ...tructions and restart the unit Ensure a distance of at least 20 cm between the unit walls Airflow seems weak Is filter dirty or clogged Please service the filters regularly as per user manual Unit is...

Страница 16: ...gs 14 14 3 GWP 3 3 All information provided is for reference only Products specifications may change due to continuous product development Disposal Do not dispose of this product as unsorted waste Col...

Страница 17: ...ugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if the issue is resolved Restart the unit 5 Check if the water tank is full 6 Was the troubleshooting guide fo...

Отзывы: